• Title/Summary/Keyword: Pulsed power

Search Result 588, Processing Time 0.031 seconds

High-Voltage AlGaN/GaN High-Electron-Mobility Transistors Using Thermal Oxidation for NiOx Passivation

  • Kim, Minki;Seok, Ogyun;Han, Min-Koo;Ha, Min-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1157-1162
    • /
    • 2013
  • We proposed AlGaN/GaN high-electron-mobility transistors (HEMTs) using thermal oxidation for NiOx passivation. Auger electron spectroscopy, secondary ion mass spectroscopy, and pulsed I-V were used to study oxidation features. The oxidation process diffused Ni and O into the AlGaN barrier and formed NiOx on the surface. The breakdown voltage of the proposed device was 1520 V while that of the conventional device was 300 V. The gate leakage current of the proposed device was 3.5 ${\mu}A/mm$ and that of the conventional device was 1116.7 ${\mu}A/mm$. The conventional device exhibited similar current in the gate-and-drain-pulsed I-V and its drain-pulsed counterpart. The gate-and-drain-pulsed current of the proposed device was about 56 % of the drain-pulsed current. This indicated that the oxidation process may form deep states having a low emission current, which then suppresses the leakage current. Our results suggest that the proposed process is suitable for achieving high breakdown voltages in the GaN-based devices.

Effect of current waveform on drop transfer in pulsed gas metal arc welding (Pulsed GMAW 의 전류 파형이 금속이행에 미치는 영향)

  • Hammad, Muhammad A.;Yoo, Choong-D.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.48-48
    • /
    • 2009
  • Conventionally in pulsed gas metal arc welding (GMAW-P), drop transfer is analyzed with simplest square pulse waveform. While the pulse current is described by four parameters (peak current magnitude and time plus base current magnitude and time), it deviates the real pulse shape. Real pulse can be better idealized by the trapezoidal pulse waveform described by two additional parameters, i.e., current rise and fall rate (dI/dt). Power source response rate is described by these parameters. In this work, the effect of these parameters on drop transfer is predicted by the force displacement model (FDM). While peak current has significant effects on drop detachment, drop transfer is also influenced by the current rise rate. Predictions indicate that the current rise rate can have considerable effects on the size of the detached drop if other pulse parameters are kept constant. FDM is applied to determine peak time for one drop one pulse condition (ODOP) when rests of the pulse parameters are given. The predicted range of ODOP shows good agreement with experimental data.

  • PDF

Pulsed-laser-diode Intermittently Pumped 2-㎛ Acousto-optic Q-switched Tm:LuAG Laser

  • Wen, Ya;Jiang, Yan;Zheng, Hao;Zhang, Hongliang;Wang, Chao;Wu, Chunting;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.238-246
    • /
    • 2020
  • The heat distribution in crystals in a 2-㎛ acousto-optic Q-switched Tm:LuAG laser pumped by pulsed-laser-diode (pulsed-LD) intermittent-pumping technology was analyzed using COMSOL software. The thermal lensing effect of the Tm:LuAG crystal can be mitigated by pulsed-LD intermittent-pumping techniques. An experimental setup using this kind of approach achieved maximum output energy of 8.31 mJ, minimum pulse width of 101.9 ns, and highest peak power of 81.55 kW, reached at a Q-switched repetition rate of 200 Hz. It offers significant improvement of performance of the output laser beam, compared to pulsed-LD double-ended pumping technology at the same repetition rate.

DEPOSITION OF c-BN FILMS BY PULSED DC BIASING IN MAGNETICALLY ENHANCED ARE METHOD

  • Lee, S.H.;Byon, E.S.;Lee, K.H.;J., Tian;Yoon, J.H.;Sung, C.;Lee, S.R.
    • Journal of Surface Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.467-471
    • /
    • 1999
  • BN films were grown on silicon (l00) substrate by magnetically enhanced activated reactive evaporation (ME-ARE) with pulsed DC power instead of r.f. for substrate biasing. The deposited films were analyzed using Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). FTIR results show that the intensity of absorption band of $sp^2$ bond of BN decreased and that of $sp^3$ bond of c-BN increased with increasing pulsed DC bias voltage applied to substrate. The initially grown layer at the interface was observed by TEM and considered to be of$ sp^2$-bonded BN. The cross-sectional and planar TEM micrographs show that the upper layer on the initial layer was the single phase c-BN. It is concluded that cubic boron nitride films could be synthesized by ME-ARE process with pulsed DC biasing.

  • PDF

Development of a HVHC-PEF Power Supply for Low Temperature Pasteurization (저온 살균용 펄스형 고압 대전류 전원장치 개발)

  • Yoo, D.W.;Kim, H.S.;Baek, J.W.;Ryoo, H.J.;Rim, G.H.;Pavlov, E.P.;Park, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2162-2164
    • /
    • 1997
  • High Voltage High Current Pulsed Electric Fields (HVHC-PEF) is a promising technology for the non-thermal pasteurization of foods and a sound complement or replacement to traditional thermal pasteurization, which inactivates bacteria and other microorganisms harmful to humans, but also degrades color, flavor, texture and nutrients. Foods can be pasteurized with pulsed electric fields at ambient or refrigerated temperatures for a short treatment time of seconds or less and the fresh-like quality of food is preserved. Although successful in laboratory tests, applying HVHC-PEF to food pasteurization on a large scale presents many unresolved engineering problems. In this paper the design considerations for 25kV 1kA class HVHC-PEF pasteurization equipment are analyzed and experimental results are discussed.

  • PDF

Magnetic Switch Auto Control Method of the High-Voltage Pulse Power Supply (고전압 펄스 전원장치용 자기스위치 자동제어 방법)

  • Kim, Soo-Hong;Lee, Jeong-Hum;Kim, Byong-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.366-373
    • /
    • 2011
  • The magnetic switch used in pulsed-power applications is superior in its high repetition rate, high stability, and long lifetime. But magnetic switch was optimized switching operation by manual control. When the load changes, the switching state can not be optimized automatically. In this paper, the auto control method of magnetic switch for high pulsed-power proposed. The magnetic switch is used capacitor charging power supply for high-voltage compressor. The proposed method can be optimized an efficiency of the system by magnetic switch auto control according to load variation. And the proposed method verify the experimental results.

A Study on Operation Characteristics of Three Electrode Trigger Gap Switch (3전극 트리거 갭 스위치 동작특성에 관한 연구)

  • Hong, Tae-Yun;Han, Sang-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.

High Repetitive Pulsed Power Supply Based on Semi-Conductor Switches (반도체 스위치 기반 고반복 펄스전원)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Kim, J.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1023_1024
    • /
    • 2009
  • In this paper, a novel 10kV, 50A, 50kHz pulsed power supply based on IGBT stacks is proposed. Proposed scheme consists of series connected 12 IGBT to generate maximum 10kV output pulse and 10kW full bridge phase-shifted zero voltage switching converter to charge DC capacitor voltage. Each IGBTs are sustain the 830V of capacitor voltage at turn off interval. By turn on the each IGBT for the same time it gives the path for the series connection of charged capacitor. From above turn on and off procedure, high voltage repetitive pulse is applied to the load. The synchronization of gating signal is important of series operation of IGBTs. For gating signal synchronization, specially designed gate power circuit using full bridge inverter and pulse transformer is developed to generate IGBT gating signal.

  • PDF

Efficient Control Method for ZVS Full-Bridge Converter with Periodic Pulsed-Load Output Dynamic Improvement (주기적인 펄스 부하에서 ZVS Full-Bridge 컨버터의 효율 증대를 위한 제어 방법과 출력 동특성 향상 분석)

  • Lee, Dong-Young;Kim, Jung-Won;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.939-941
    • /
    • 2001
  • An efficient control method of ZVS Full-bridge PWM converter with a periodic pulsed-load current is proposed. This novel control method can reduce the switching loss of switches during no load condition. Moreover, by using feed-forwarded load current information this method can obtain better transient dynamics compared to the system with only linear feedback control.

  • PDF

Electromagnetic Launcher Sub-scaling Relationships and Small System Design for Research and Educational Purposes

  • Yun, Heedo
    • Journal of Magnetics
    • /
    • v.5 no.2
    • /
    • pp.65-71
    • /
    • 2000
  • Although the electromagnetic launcher technology has been progressed significantly during the past two decades the number of firing test facilities are not many. This is prbably due to the large budget and man power required to build and maintain full scale electromagnetic launcher facilities. As the EM launcher technology's potential capabilities have been somewhat demonstrated with the full scale large systems the research is now headed more toward overcoming specific difficulties and answering questions experimentally with smaller, cost effective systems. The first half of this paper presents EM launcher's improved sub-scaling relationships based upon magnetic, thermal and momentum differential equations and EM launcher's basic equations. With the proposed scaling method the field variables can be matched or scaled linearly between the two geometrically scaled systems. The second half of the paper presents pulsed power system's circuit analysis and design technique, which is applied to the capacitor-powered small pulsed power system with crow-barring circuitry. The effect of the so-called speed volt is included. A sub-scaled small system's design is provided as an example.

  • PDF