• Title/Summary/Keyword: Pulse-on duration

Search Result 332, Processing Time 0.031 seconds

Study of The Anisotropy of Electron Energy Distribution of Optical-Field Ionized Oxygen Plasma by Using Polarization Spectroscopy

  • Kim, Dong-Eon;Kim, Jae-Hoon;Kawachi, Tetsuya;Hasegawa, Noboru;Sukegawa, Kouta;Iwamae, Atsushi;Fujimoto, Takashi
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.145-149
    • /
    • 2003
  • The anisotropy of electron energy distribution in oxygen plasmas produced by a high intensity laser was investigated by using polarization spectroscopy. An ultra-short pulsed laser with a pulse duration of 66.5 fs and a power density of $1 {\times} 10^17/ W/$\textrm{cm}^2$$ was used. At this power density and pulse duration, the plasma was generated predominantly by optical field ionization. The degree of polarization of OVI 1s$^2$2p$^2$p2- 1s$^2$4d$^2$D$^{0}$ (J = 1/2-3/2 and 3/2-5/2) transition line at 129.92 $\AA$ was measured. O VI 1s$^2$2p$^2$P$^2$ -1s$^2$4s$^2$S$^2$ (J = 1/2-1/2 and 3/2-1/2) transition line at 132.26 $\AA$ was used to calibrate the sensitivity of the optical system. The dependencies of the degree of polarization on the initial gas density and on the laser polarization were investigated. When the laser polarization was changed from a linear to a circular polarization, the degree of polarization was decreased. When the initial gas density was increased, the degree of polarization was decreased.

Hot Firing Test of a Quadrature NEA SSD9103S1 Configuration

  • Ja-Chun, Koo;Hee-Sung, Park;Max, Guba
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.1-9
    • /
    • 2022
  • The NEA release mechanism is used to provide restraint and release functions with low shock for critical deployment operations on solar arrays after launch. The GK3 solar array consists of 2 wings and 6 hold down points per panel. The NEA SSD9103S1 is a part of the GK3 solar array hold-down and release mechanism. Each NEA unit is equipped with two Z-diodes which provide power to a NEA unit connected in series after actuation of the fuse wire. This paper presents the hot firing test results of a quadrature NEA SSD9103S1 configuration. One output powers a maximum of 4 NEA SSD9103S1 units simultaneously. The necessary actuation pulse duration has been determined to meet margin requirement for thermal energy of minimum 4. Actuation thermal energy difference is about 6.6% between each half of two fired serial NEAs. Thermal energy margin at worst case is minimum 5.9 in case of an actuation pulse duration of 500 ms. Two series Zener impedance depend on current applied has been characterized by an additional actuation after all fuse wires are open circuit. Total number of actuation commands to the GK3 NEA unit reduce drastically from 24 in case of single NEA configuration down to 8 in case of parallel and quadrature NEA configurations. It can be accommodated by the existing HP2U Pyro design without any impact.

Implementation of Intelligent Electronic Acupuncture Needles Based on Bluetooth

  • Han, Chang Pyoung;Hong, You Sik
    • International journal of advanced smart convergence
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2020
  • In this paper, we present electronic acupuncture needles we have developed using intelligence technology based on Bluetooth in order to allow anyone to simply receive customized remote diagnosis and treatment by clicking on the menu of the smartphone regardless of time and place. In order to determine the health condition and disease of patients, we have developed a software and a hardware of electronic acupuncture needles, operating on Bluetooth which transmits biometric data to oriental medical doctors using the functions of automatically determining pulse diagnosis, tongue diagnosis, and oxygen saturation; the functions are most commonly used in herbal treatment. In addition, using fuzzy logic and reasoning based on smartphones, we present in this paper an algorithm and the results of completion of hardware implementation for electronic acupuncture needles, appropriate for the body conditions of patients; the algorithm and the hardware implementation are for a treatment time duration by electronic acupuncture needles, an automatic determinations of pulse diagnosis, tongue diagnosis, and oxygen saturation, a function implementation for automatic display of acupuncture point, and a strength adjustment of electronic acupuncture needles. As a result of our simulation, we have shown that the treatment of patients, performed using an Electronic Acupuncture Needles based on intelligence, is more efficient compared to the treatment that was performed before.

Theoretical Analysis on the Optimum Fluence for Copper Ablation with a 515 nm Picosecond Laser (515 nm 피코초 레이저를 이용한 구리 어블레이션 공정의 최적 에너지밀도에 대한 이론적 분석)

  • Shin, Dongsig;Cho, Yongkwon;Sohn, Hyonkee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1009-1015
    • /
    • 2013
  • Ultra-short laser pulses are effective, when high requirements concerning accuracy, surface roughness and heat affected zone are demanded for surface structuring. In particular, picosecond laser systems that are suited to be operated in industrial environments are of great interest for many practical applications. This paper focused on inducing optimum process parameters for higher volume ablation rate by analyzing a relationship between crater diameter and optical spot size. In detail, the dependency of the volume ablation rate, penetration depth and threshold fluence on the pulse duration 8 ps and wavelength of 515 nm was discussed. The experimental results showed that wavelength of 515 nm resulted in less threshold fluence ($0.075J/cm^2$) on copper than IR wavelength ($0.3J/cm^2$). As a result, it was possible that optimum fluence for higher volume ablation rate was achieved with $0.28J/cm^2$.

A Meta-Analysis of the Effects of Imagery (국내 간호연구에서 적용된 심상요법 효과에 대한 메타분석)

  • 오원옥;석민현
    • Journal of Korean Academy of Nursing
    • /
    • v.32 no.2
    • /
    • pp.265-276
    • /
    • 2002
  • This study was to identify the trends and contents of imagery interventions and to evaluate the effects of imagery interventions by using meta-analysis. Method: The materials used for this study were 15 imagery intervention studies carried out from Jan. 1995 to Dec. 2001. The studies were analyzed and evaluated in different categories: 1) types of dependent variables 2) types of imagery 3) interval of imagery 4) total duration of imagery 5) sample characteristics 6) intervention method. Result: 1) Behavioral imagery was more prevalent than dynamic imagery. There were wide variations in duration, and interval of interventions. Imagery intervention had moderate effects on psychological variables (state of anxiety, depression & and stress etc.) and had moderate to large effects on physiological variable(pulse rate, cortisol etc.). Behavioral imagery had larger effects than dynamic imagery. Imagery applied to the public had larger effect on decreasing the state of anxiety and stress than applied to the patients. But imagery applied to the patients had a larger effect on decreasing depression than applied to the public. The imagery intervention method by using the individual approach had greater effect than group approach method. Conclusion: These results of this study will be used to guide the development of imagery interventions to nursing practice. Also, various types of imagery interventions need to be developed based on the characteristics of nursing practice.

An Acoustical Study on the Syllable Structures of Korean Numeric Sounds

  • Yang, Byung-Gon
    • Speech Sciences
    • /
    • v.14 no.1
    • /
    • pp.137-147
    • /
    • 2007
  • The purpose of this study was to examine the syllable structures of ten Korean numeric sounds produced by ten students. Each sound was normalized by its maximum intensity value and divided into onset, vowel, and coda sections after finding abrupt or visible changes in energy values or cumulative values of lower spectral energy at each pulse point using four Praat scripts. Then, segmental durations and cumulative intensity values of each syllable were obtained to find a statistical summary of the syllable structure. Intensity values at 100 proportional time points were also collected to compare the ten sounds. Results showed as follows: Firstly, there was not much deviation from the grand average duration and intensity for the majority of the sounds except the two diphthongal sounds on which their boundary points varied among the speakers. Secondly, the onset point for the CV or CVC category sounds and the boundary between the vowel and the nasal or lateral sound were easy to identify, which may be automatically traced later. Thirdly, there seems some tradeoff among the sections maintaining the same total duration per each syllable. Further studies on syllables with various onsets or codas would be desirable to make a general statement on the Korean syllable structure.

  • PDF

A Novel Method for Compensating Phase Voltage Based on Online Calculating Compensation Time

  • Wang, Mingyu;Wang, Dafang;Zhou, Chuanwei;Liang, Xiu;Dong, Guanglin
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.333-343
    • /
    • 2019
  • Dead time and the nonideal characteristics of components all lead to phase voltage distortions. In order to eliminate the harmful effects caused by distortion, numerous methods have been proposed. The efficacy of a method mainly depends on two factors, the compensation voltage amplitude and the phase current polarity. Theoretical derivations and experiments are given to explain that both of these key factors can be deduced from the compensation time, which is defined as the error time between the ideal phase voltage duration and the actual phase voltage duration in one Pulse Width Modulation (PWM) period. Based on this regularity, a novel method for compensating phase voltage has been proposed. A simple circuit is constructed to realize the real-time feedback of the phase voltage. Utilizing the actual phase voltage, the compensation time is calculated online. Then the compensation voltage is derived. Simulation and experimental results show the feasibility and effectivity of the proposed method. They also show that the error voltage is decreased and that the waveform is improved.

CHANGES OF JAW-OPENING REFLEX DEGREE ACCORDING TO ELECTROACUPUNCTURE DURATION ON ZUSANLI (족삼리의 전기침 자극에 대한 개구반사 크기의 변화)

  • Seo, Young-Ah;Song, Hyung-Geun;Na, Chang-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.788-796
    • /
    • 1998
  • The purpose of this study was to investigate the effect of various electroacupuncture duration induced by acupuncture point-Zusanli ($S_{36}$) electrical stimulation on inhibition of amplitude of digastric electromyogram (dEMG) evoked by noxious electrical stimuli around the mental foramen. intraperitoneal sodium pentobarbital in an initial dose of 50mg/kg and maintenance doses of 4.5mg/kg/h were given through a cannula in the femoral vein using a constant infusion pump. A pair of stimulating electrodes were inserted for noxious stimuli around the mental foramen. An irritant electronic stimuli pulse (0.2 Hz, 0.1 ms duration) was produced with an intensity of about $1.5{\times}2$ times threshold for evoking the dEMG. The anterior belly of the digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for dEMG recording. Acupuncture point stimulation on Zusanli (2 Hz, 250 ${\mu}s$, biphasic pulse, 2 V) was delivered by Dental Electronic Anesthesia (3M, U.S.A). For periods of electronic stimulation of 10, 20, and 30min, the amplitudes of dEMG were measured on the oscilloscope and on the monitor connected to the amplifier. The following results were obtained: The dEMG was decreased to 73.4% of that in the control set after 10 min electroacupunture stimulation (Group I); The dEMG was decreased to 77.1% (10min), 54.0.% (20min) of that in the control set after 20minutes of electroacupunture stimulation (Group II). The dEMG was decreased to 73.3% (10min), 61.9% (20min), 76.2% (30min) of that in the control set after 30 min of electroacupunture stimulation (Group III). From these results, it may be that in the electroacupuncture stimulation on the Zusnali resulted in a reduction of amplitude of dEMG and that the most effective electroacupuncture stimulation period was 20min.

  • PDF

Impact of Group Delay in RF BPF on Impulse Radio Systems (임펄스 라디오 시스템에서 RF 대역 통과 필터의 군지연 영향 분석)

  • Myoung Seong-Sik;Kwon Bong-Su;Kim Young-Hwan;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.380-388
    • /
    • 2005
  • This paper presents analysis results of the effects of RF filter characteristics on the system performance of impulse radio. The impulse radio system transmits modulated pulses having very short time duration and information can be extracted in receiver side based on cross-correlation between received and transmitted pulses. Accordingly, the pulse distortion due to in-band group delay variation can cause serious system performance degradation. In general, RF bandpass filters inevitably cause group delay difference to the signal passing through the filter which is proportional to its skirt characteristic due to its resonance phenomenon. For time as well as frequency domain analysis, small signal scattering parameter $S_{21}$ and its Fourier transform are used to characterize output pulse waveform under the condition that the input and output ports are matched. The output pulse waveform of the filter is predicted based on convolution integral between input pulse and filter transfer function, and resulting BER performances in the BPM and PPM based impulse radio system are calculated.

Study on Relation of Stimulated Duration and Depth of Electroacupuncture with Sex and Weight In Rats (흰쥐의 성별과 체중에 따른 족삼리(足三里) 전침자극의 시간과 심도(深度)의 변화가 수장수송능(小腸輸送能)에 미치는 영향)

  • Kim, Young-Sam;Yu, Yun-Cho;Oh, Inn-Kun;Kim, Myung-Dong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.444-452
    • /
    • 2007
  • Acupuncture treatment cures disease by regulating the functional excessiveness or deficiency which occurs in the meridian and visceral organs, and by letting stagnated Qi and Blood flow through the whole body and then controlling Qi. Whether or not to have Qi feeling is the main factor needed to manifest the efficacy of acupuncture. So it needs the very stimulus to make Qi felt rather than the simple stimulus. In order to have Qi feeling, it needs to acupuncture a patient according to patient's thinness or fatness, constitution, richness or poverty and age. And also it needs to vary the way to acupuncture a patient according to meridian, kinds of pulse, degrees of disease, new or old diseases, seasons with a disease and local areas of disease. In order to ascertain that it is important for the quality and quantity of acupuncture stimulus and the state of feeling acupuncture to get the efficacy of acupuncture, the experiment was planned to confirm whether the form and Qi of subject has different result according to the stimulated duration and depth. On the basis of the report that acupuncture on derma, when using electroacupuncture at Zusanli(ST 36) which denotes small intestinal motility, is more efficient than full depth acupuncture, I got the following result, after I observed whether the stimulated duration and depth give different efficacy according to the sex and weights of rat in experiment. The increased effects of small intestinal motility by electroacupuncture on Zusanli(ST 36) appeared after stimulating full depth for thirty minutes without distinction of sex and weights. This significant change was observed only in the female experimental group when I distinguished the sex. The small interstinal motility in rats by electroacupuncture at zusanli(ST 36) decreased in the 10 minutes' stimulated group and 30 minutes' stimulated group by duration on the one hand, and derma-deep stimulated group and full depth stimulated group by the depth of stimulus on the other hand, as the weights increased. This result shows that the duration and depth of acupuncture depends on the differences of acupuncture points, sex of the experimental animals, ages, and, weights. And the further study on the experimental and clinical differences and sextual differences need to be continued on.