• Title/Summary/Keyword: Pulse-Induction

Search Result 240, Processing Time 0.025 seconds

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

A New Space Vector Random PWM Scheme for Inverter Fed Drive Systems (인버터 구동 시스템을 위한 새로운 공간벡터 Random PWM기법)

  • 나석환;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.525-537
    • /
    • 2001
  • In this paper a new space vector RPPWM(Random Position PWM) is proposed. In the propsed RPPWM each of three phase pulses is located randomly in each switching interval. Based on the Space vector modulation technique the duty ratio of the pulses is calculated Along with the randomization of the PWM pulses. we can obtain the effects of spread spectra of votlage, current as in the case of randomly changed switching frequency, To verify the validity of the proposed RPPWM simulation study was tried using Matlab/Simulink The main model described in Simulink block diagrams includes the space vector modulation block pulse position randomization block inverter block 3 phase induction motor block and so on By the simulation study, the harmonics of the output voltage and the current of inverter are predicted in different PWM methods- SVPWM, LLPWM proposed RPPWM.

  • PDF

Development and Application of H-Bridge Multilevel Inverter for High-Voltage & High-Power Induction Motor Drives (고전압 대용량 유도 전동기 구동용 H-브릿지 멀티레벨 인버터의 개발 및 적용)

  • Park, Young-Min;Ryu, Han-Seong;Lee, Hyun-Won;Jung, Myung-Gil;Lee, Se-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.559-561
    • /
    • 2008
  • 본 논문에서는 실용적이며 신뢰성 있는 고전압 대용량 유도전동기 구동용 H-브릿지 멀티레벨 인버터를 개발하여 산업 현장에 적용한 내용을 소개하였다. 실용적인 PWM (Pulse Width Modulation)과 PEBB (Power Electronics Building Blocks)에 기초한 신뢰성 있는 분산 제어를 적용하였으며, H-브릿지 멀티레벨 인버터를 이용한 유도 전동기 벡터 제어시의 위상지연을 보상하여 제어 성능을 향상시켰다. 또한, Power Cell 고장 발생시 시스템을 정지하지 않으면서 효율적 운전을 가능하게 하는 3상 불평형 제어를 이용하여 잉여성을 확보하였다. 다양한 전압과 용량의 H-브릿지 멀티레벨 인버터를 설계 및 제작하여 각종 부하 실험, 산업 현장 적용을 통해 적용된 방법의 타당성과 실용성을 입증하였다. 또한 실제 제품 설계, 생산, 판매, 유지 보수 과정을 통해 설계의 유연성, 생산의 효율성, 유지 보수의 편리함, 그리고 사용자 요구에 대한 대응성이 우수함을 확인하였다.

  • PDF

A Novel Control Algorithm of a Three-phase PWM Inverter with LC Filter (정현파 출력 필터를 가지는 3상 PWM 인버터 제어 기법)

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.239-246
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of second-order low pass filter(LPF), which has a zero damping ratio. A simple method of implementing second-order LPF with damping ratio is to add a resistor in an LC circuit. However, in a real power system, adopting damping resistors is impractical because it results in losses proportional to the square of the current flowing through the resistors. Instead of inserting resistors, the proposed control strategy utilizes the measured capacitor voltages to control the oscillation of LC circuit. The overall transfer function of the proposed method is the same as a second-order LPF, and its damping ratio is controllable via control variables. The current controller can have overshoots caused by LC filter. Improved current controller is implemented by an equivalent second-order of LC filter. A 7.5 kVA PWM converter and a PWM inverter with a 5.5 kW induction motor are set up to verify the proposed control algorithm. Test waveforms are also presented to verify the proposed LC filter control algorithm.

An Evaluation of Voltage Source PAWM Inverter by Torque Ripple Content (토오크 맥동량에 의한 전압원 PAWM 인버터의 평가)

  • Lee, Chi-Hwan;Koo, Bon-Ho;Kwon, Wo-Hyen
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.5
    • /
    • pp.60-70
    • /
    • 1989
  • In this paper, a new HTF(Harmonic torque function) which takes into account the phasor of harmonic current, and which represents torque ripple content of induction motor is proposed. Through experiments and computer simulations using direct-quadrature two axis model, the proposed HTF is proved to be valid. Applying this function, six-step, SPWM and TPWM pulse-amplitude-width-controlled inverters are evaluated and compared with each other. A good control strategy for PAWM inverters was chosen from the results. It turns out that TPWM is superior to SPWM in torqur ripple content and output voltage amplitude of fundamental wave and six-step is better than PWM when CR is 9.

  • PDF

Application of Bacterial Foraging Algorithm and Genetic Algorithm for Selective Voltage Harmonic Elimination in PWM Inverter

  • Maheswaran, D.;Rajasekar, N.;Priya, K.;Ashok kumar, L.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.944-951
    • /
    • 2015
  • Pulse Width Modulation (PWM) techniques are increasingly employed for PWM inverter fed induction motor drive. Among various popular PWM methods used, Selective Harmonic Elimination PWM (SHEPWM) has been widely accepted for its better harmonic elimination capability. In addition, using SHEPWM, it is also possible to maintain better voltage regulation. Hence, in this paper, an attempt has been made to apply Bacterial Foraging Algorithm (BFA) for solving selective harmonic elimination problem. The problem of voltage harmonic elimination together with output voltage regulation is drafted as an optimization task and the solution is sought through proposed method. For performance comparison of BFA, the results obtained are compared with other techniques such as derivative based Newton-Raphson method, and Genetic Algorithm. From the comparison, it can be observed that BFA based approach yields better results. Further, it provides superior convergence, reduced computational burden, and guaranteed global optima. The simulation results are validated through experimental findings.

Studies on the Induction of Transformation in Cereal Plants.II. Expression of Gene Transferred into Rice Protoplasts by Electroporation (곡물류의 형질전환에 관한 연구.II. Electroporation에 의해 벼 원형질체로 도입된 유전자의 발현)

  • Hwang, Baik;Hwang, Sung-Jin;Im, Wook-Bin;Im, Hyong-Tak;Kang, Young-Hee
    • KSBB Journal
    • /
    • v.5 no.4
    • /
    • pp.323-327
    • /
    • 1990
  • Protoplasts isolated from embryogenic cell suspensions were electroporated in buffered solutions containing plasmid DNA of pBI121. Transient GUS (beta-glucuronidase) activity measurement and selection for kanamycin resistent showed that expression of foreign genes and stable loransformation were achieved. GUS transient gene expression was increased by increasing DNA concentration of pBI121 plasmid and affected by the level of the applied voltage. An optimal level of GUS activity was obtained after electroporation with a pulse of 200 voltage/1180 uF. Protoplast viability was up to the 60% at the optimal voltage. Cell colonies resistent to 200$\mu\textrm{g}$/ml kanamycin were selected in agar medium and identified by histochemical GUS assay.

  • PDF

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals (오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템)

  • Kim, Nam-Hun;Kim, Min-Heui;Choi, Chang-Ho;Lee, Sang-Hoon;Choi, Keyng-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

Spray and Depositional Characteristics of Electrostatic Nozzles for Orchard Sprayers (과수 방제기용 정전대전 노즐의 분무 및 부착특성)

  • 강태경;이동현;이채식;이공인;최완규;노수영
    • Journal of Biosystems Engineering
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2004
  • Spraying is one of the most efficient methods for pesticide and insecticide control. Generally, orchard sprayers(aircarrier sprayer) are used for such applications. However, when an orchard sprayer is used, only 20% of total amount of spray deposits on the target. The rest of spray are not only wasted but are also potential sources of environmental pollution. The research far the development of electrostatic spraying system for orchard sprayer was conducted to develop the new pesticide application technology for the reduction of environmental pollution and f3r the production of safe agricultural products. The spray characteristics for nozzles with the different charging methods were tested and the effect of electrostatic charge was analyzed, in the laboratory experiments. The results of this study indicate that the capacitive type of electrostatic spraying nozzle exhibits a large current deposition of water sprays on the sample target. The covering area ratio by conventional spraying system was 10.2%, while that of electrostatic sprays with pulse induction charging method gave the increased covering area ratio by 4.3 times.