• Title/Summary/Keyword: Pulse wave

Search Result 1,037, Processing Time 0.044 seconds

Effect of Mountain Cultivated Ginseng Pharmacopuncture on Heart Rate Variability(HRV), Pulse Wave Velocity(PWV) in Middle Aged Women (산양삼약침이 정상 중년여성의 심박변이도(HRV), 맥파속도(PWV)에 미치는 영향)

  • Park, Sang-Wook;Kim, Yi-Soon;Hwang, Won-Deok;Kim, Gyeong-Cheol
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.97-105
    • /
    • 2011
  • Objectives : The aim of this experiment is to know the effect of mountain cultivated ginseng pharmacopuncture on heart rate variability(HRV), pulse wave velocity(PWV) in middle aged women. Methods : We investigated on 20 healthy Middle Aged women volunteers. First, we measured their heart rate variability(HRV), pulse wave velocity(PWV) and then mountain cultivated ginseng pharmacopuncture 20cc were injected on them. After 30 minutes, we measured heart rate variability(HRV), pulse wave velocity(PWV) again. As a result, method of one-group pretest-posttes design were used for evaluation. Results : 1. In HRV, MeanHRV is significantly decreased from 69.15 to 63.34 after injection. 2. MeanRR is significantly increased from 877.20 to 962.10 after injection. SDNN is significantly increased from 32.56 to 41.34 after injection. 3. PNN50 is significantly decreased after injection. RNSSD, SDSD, TP, VLF is significantly increased after injection. 4. Stress resistance ability is significantly increased from 37.55 to 44.60 after injection. 5. In PWV, E-R, E-L, H-R, H-L is significantly decreased after injection. Conclusions : Effect of mountain cultivated ginseng pharmacopuncture on heart rate variability(HRV) increased adaptability of autonomic nervous system and on pulse wave velocity(PWV) decreased arterial stiffness.

A STUDY ON THE SELF-MATCHED LINE PULSE GENERATOR (자기정합 선로형 펄스 발생기에 관한 연구)

  • Paek, Yong-Hyun;Sohn, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.184-187
    • /
    • 1990
  • This paper presents the self-matched line pulse generator and the concerned principles on its operation and characteristics are mentioned. The circuit consists of a charged transmission line and a high speed switch, and it generates a square wave pulse with the very fast rise time. The generated waveform depends on the load resistance. As the load resistance is infinite, a single rectangular wave pulse is generated and its efficiency is nearly unity.

  • PDF

Accuracy Analysis of Pulse Wave Sensor Data of Ear Label of Husbandry Livestock (축산 가축 이표용 맥파 센서의 데이터 정확도 분석)

  • Kim, Il-Gon;Kang, So-Hyung
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.387-393
    • /
    • 2014
  • In this research, we aimed to investigate the most optimum pulse wave sensor to ear label of live stocks among pulse wave piezo film sensor, conductive textile sensor, photo sensor. As a result of this research with application to 10 cattle, 10 pigs objects with pulse wave piezo film sensor, conductive textile sensor, photo sensor, photo sensor shows less standard deviation to average value than piezo film sensor or conductive textile sensor which means it is the most stable for the cattle. With pigs, piezo film sensor, conductive textile sensor and photo sensor all show stable pulse rate. Thus, to take pulse rate of livestock with curved body and long and dense coat such as cow, photo sensor will be considered as the most efficient mean.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

The Effects of Plasma Homocysteine Concentration on Upper Arm-Ankle Pulse Wave Velocity (혈장 호모시스테인 농도가 상완-발목 맥파 속도에 미치는 영향)

  • Kang, Ji-Hun;Shin, Sang-Yol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.673-680
    • /
    • 2019
  • This study was conducted to investigate the effects of plasma homocysteine concentration on the brachial-ankle pulse wave velocity between the normal homocysteine group and the asymptomatic high homocysteine group. 435 subjects who visited the general health examination center from April 1 to October 31, 2016, as well as to compare the direct correlation of the brachial-ankle pulse wave velocity, which indirectly reflects the homocysteine test and arterial stiffness, as a predictor of future cardiovascular outcome. As a result of the study, age, waist circumference, BUN, and plasma creatinine were significantly higher, and HDL was significantly lower in the high homocysteine group (> $15{\mu}mol/L$) than in the normal homocysteine group (< $15{\mu}mol/L$) (p=0.05). In addition, homocysteinemia was associated with smoking and drinking (p<0.001) and was significantly higher in males (p<0.001). The right and left brachial-to-ankle pulse wave velocities were significantly higher in the high homocysteine group (right p<0.001, left p=0.003) before calibrating the relevant variables. There was no significant difference between right and left brachial-to-ankle pulse wave velocities after calibrating the relevant variables. Therefore, further studies on the independent association of lowering homocysteine concentration and prevention of cardiovascular disease and the relationship between homocysteine and renal function are needed.

Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation (침자극이 좌관맥상과 심박수 미세변화에 미치는 영향)

  • Won, Jae-Kyun;Jung, Soon-Kwan;Kim, Dong-Eun;Lim, Jin-Young;Kwon, Young-Dal;Yeom, Seung-Ryong;Lee, Su-Kyung;Song, Yung-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

A Study of the Cardiovascular Aging Effect on the Pulse Shape (심혈관 노화가 맥상(脈象)에 미치는 영향)

  • Shin, Sang-Hoon;Rhim, Hye-Whon;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.59-68
    • /
    • 2005
  • Background and purpose: Cardiovascular disease will undoubtedly rise along with the aging of the 'baby-boom' generation. The purpose of this study is to find the new index of the cardiovascular aging. Methods: The effects of aging on the heart and the arterial system are surveyed in the point of structure and function. Results: Arterial stiffening is due to the fatiguing effects of periodic stress on the arterial wall and is the main reason for increasing pulse wave velocity. The systolic hypertension is caused by the early return of wave reflection. The increased after-load by the arterial change leads to the development of left ventricular hypertrophy. The reduction in left ventricular compliance cause the impairments of the diastolic function. In contrast to the lower limb, aging effect in the upper limb are almost due to the ascending aortic pressure wave and the reflected wave from the lower limb. Conclusion: We have the following points. (1) The change of physiological pulse pattern by age can be explained by the early returning of reflected wave. (2) The atrial pulse in old age are generated by the left ventricular hypertrophy.

  • PDF

Simulation Study of Characteristics for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 특성에 관한 시뮬레이션 연구)

  • Kim, Young-Ju;Shin, Ju-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.80-86
    • /
    • 2012
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows the high-voltage pulse generator simulation using a circuit program with experiment data. In the equivalent circuit, magnetized inductances and loss resistances which affect output voltage, have been obtained. The output capacitor circuits have characteristics of band pass. The output voltages of the pulse width 50% and 25%(PWM) were obtained. The output of the high-voltage pulse generator is 2.5kHz, 1.8kV.

The Classification and Frequency Analysis in Radial Pulse (맥파의 인식상의 분류와 주파수 해석)

  • Kil, S.K.;Han, S.H.;Kwon, O.S.;Park, S.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.263-264
    • /
    • 1998
  • In this paper, we present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. And we analyze radial pulse in frequency domain. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also fie specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm, then we classify the shape of radial pulse by existence and position of feature points. lastly we execute frequency analysis on the feature points and get the power spectrum of radial pulse.

  • PDF