• 제목/요약/키워드: Pulse tube

검색결과 254건 처리시간 0.023초

동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구 (A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF

소형 관성관 맥동관 냉동기의 단열 해석 및 성능 실험 (Adiabatic analysis and performance experiment of miniature inertance pulse tube refrigerator)

  • 남중원;남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.28-32
    • /
    • 2003
  • Miniature inertance pulse tube refrigerator was designed and fabricated to provide optimal performance with 10W compressor. An adiabatic model was used to design an inertance pulse tube refrigerator. Among the various design parameters which should be optimized, pulse tube length and inertance tube length were considered. PdV work and various losses were calculated for various pulse tube and inertance tube length. Experiments were carried out for different pulse tube length and inertance tube length. It was shown that the experimental results were similar to the calculated results. The reason why the quantitative optimal point exists is explained.

  • PDF

소형 관성관형 맥동관 냉동기의 실험 및 단열 해석 (Experiment and adiabatic analysis of miniature inertance pulse tube refrigerator)

  • 남중원;남관우;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.53-58
    • /
    • 2004
  • A Miniature inertance pulse tube refrigerator was designed and tested with a 10 W compressor. Erperiments were carried out for different pulse tube length and inertance tube length. An adiabatic model which considered the pressure drop in the regenerator was used to analyze the performance of the pulse tube refrigerator. Among various design parameters which should be optimized, the pulse tube length and the inertance tube length were optimized. PdV work and several different loss mechanism were included in the analysis to simulate more accurately the physical phenomena in the pulse tube refrigerator. Nevertheless, the simulation program could not completely predict the porformance of the refrigerator. The possible reason for the difference of the optimal point between the simulation and the experiment was explained.

Three Buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of a Therr Buffer Pulse Tube Refrigerator)

  • 박성재;고득용;김효봉;신완순
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF

77K Inertance tube 맥동관 극저온 냉동기에 관한 연구 (An Experimental Study for the 77K Inertance Tube Pulse Tube Cryocooler)

  • 박성제;고득용;김효봉
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.17-27
    • /
    • 1999
  • The experimental results of the 17K inertance tube pulse tube cryocooler for cooling cryosensors are presented in this paper. In prototype experiments, linear compressor is driven by linear motor, and inertance tubes are inserted between one liter reservoir and pulse tube. Design of the inertance tube pulse tube cryo-cooler is conducted by ARCOPTR program of NASA Ames Research Center. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature and refrigeration capacity according to the variations of inertance tube volume, reservoir volume and charging pressure are measured. and the cool down and load characteristics at the particular conditions are presented. As the representative results, no load temperature of the cold end is 52.7K and refrigeration capacity is 5W at 72K..

  • PDF

Design of compact phase controller for pulse tube refrigerator

  • Ki, Tae-Kyung;Jeong, Sang-Kwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.25-28
    • /
    • 2011
  • A compact phase controller of pulse tube refrigerator is proposed in this paper. Most pulse tube refrigerators available now consist of a long inertance tube and reservoir as the phase controller. The long inertance tube and reservoir present a challenge for compact packaging in some applications. To overcome this disadvantage, the long inertance tube and reservoir are replaced with the compact phase controller consisted of mass, spring and damper in pulse tube refrigerator. This process is achieved using similarity of mechanical, electrical, and acoustic system and the specific configuration of the compact phase controller is designed. From the simulation code in this paper, the performance of pulse tube refrigerator with the designed compact phase controller is confirmed to be comparable to pulse tube refrigerator with the long inertance tube and reservoir.

Experimental results of Stilting type Pulse Tube refrigerator with inertance tube

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong;Park, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.118-122
    • /
    • 2003
  • Pulse tube refrigerator, which has no moving parts at its cold section, is attractive fer obtaining higher reliability, simpler construction and lower vibration than Stilting refrigerator or Gifford-McMahon refrigerator. Commonly used means to achieve optimum performance of Stilting type pulse tube refrigerator is an inertance tube. The use of inertance tube is a simple way to generate the phase shift needed to make pulse tube refrigerator operate as efficiently as Stilting refrigerator. In this study, the performance of the inertance pulse tube refrigerator (IPTR) was investigated experimentally. An in-line type IPTR consists of a linear compressor with two reciprocating pistons driven by linear motors, which makes pressure waves, a regenerator a pulse tube with the inertance tube, and a reservoir, The dynamic pressures (the compressor, pulse tube, reservior) and the temperature at the cold heat exchanger are measured to explore the dependence of the inertance tube on the performance of the IPTR. The experimental results show the dependency of cool-down characteristics, no-load temperature and amplitude of the pressures on the length and diameter of the inertance tube.

Net Enthalpy Transport in Pulse Tube Refrigerators

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.33-44
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube was constant. The time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass and enthalpy streaming. Effects of the axial temperature gradient, velocity amplitude ratio, and heat transfer between the gas and the tube wall On the steady mass and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Parametric Study on Performance of Inertance Pulse Tube Cryocooler

  • Lee, K.H.;Rhee, J.;Kim, J.S.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.205-211
    • /
    • 2014
  • The design parameters to affect the cooling capacity of a cryocooler were examined with the application of numerical modeling to optimize an inertance pulse tube cryocooler. This modeling includes the regenerator, pulse tube, inertance tube, gas reservoir, and heat exchangers. One-dimensional modeling on strings of acoustic and thermoacoustic elements was applied to compare the design parameters. The diameter and length of the pulse tube can significantly affect the cooling capacity and efficiency. The aftercooler was optimized by maintaining a certain size. The efficiency also improved as the length of inertance tube and volume of gas reservoir are increased. It was confirmed that effective design parameters are critical to the performance of an inertance pulse tube cryocooler considering the comparison of the dimensions of each part to optimize its cooling power and efficiency.

맥동관냉동기의 앤탈피이동 (Enthalpy transport in pulse tube refrigerators)

  • 강영구;정은수
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.180-192
    • /
    • 1998
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube is constant. Time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass streaming and enthalpy streaming. Effects of axial temperature gradient, velocity amplitude ratio and heat transfer between the gas and the wall on the steady mass streaming and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF