• 제목/요약/키워드: Pulse therapy

검색결과 326건 처리시간 0.021초

개인용 고주파 전기자극기의 주파수 가변 설계 및 출력 특성의 분석 (Analysis of Output Characteristics and Frequency Variation Design for Personal High Frequency Electrical Stimulation Medical Devices)

  • 장경욱;임지현;백승명;손진근
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.25-30
    • /
    • 2016
  • In this paper, personal electrical stimulation medcial devices using bioelectrical stimulating was developed. Therapy effect of RET(resistive electric transfer) was more effective than CET(capacitive electric transfer), but CET was adopted because of safety issue. Then, the optimum parameters that may be effective in thin skin or facial wrinkles was set. For example, the frequency of the pulse voltage for stimulation is 1.8[MHz], burst frequency is 7[kHz] or 400[Hz], the development of devices was to have ON/OFF control and frequency control. When burst frequency was adjusted 7[kHz], heat was generated in the electrode. The case of 400[Hz] the heat was little generated. The microcontroller ATmega128-based experimental results show that the proposed personal high frequency electrical stimulation devices can be applied to medical equipment using therapy effect successfully.

Muscular Adaptations and Novel Magnetic Resonance Characterizations of Spinal Cord Injury

  • Lim, Woo-Taek
    • 한국전문물리치료학회지
    • /
    • 제22권2호
    • /
    • pp.70-80
    • /
    • 2015
  • The spinal cord is highly complex, consisting of a specialized neural network that comprised both neuronal and non-neuronal cells. Any kind of injury and/or insult to the spinal cord leads to a series of damaging events resulting in motor and/or sensory deficits below the level of injury. As a result, muscle paralysis (or paresis) leading to muscle atrophy or shrinking of the muscle along with changes in muscle fiber type, and contractile properties have been observed. Traditionally, histology had been used as a gold standard to characterize spinal cord injury (SCI)-induced adaptation in spinal cord and skeletal muscle. However, histology measurements is invasive and cannot be used for longitudinal analysis. Therefore, the use of conventional magnetic resonance imaging (MRI) is promoted to be used as an alternative non-invasive method, which allows the repeated measurements over time and secures the safety against radiation by using radiofrequency pulse. Currently, many of pathological changes and adaptations occurring after SCI can be measured by MRI methods, specifically 3-dimensional MRI with the advanced diffusion tensor imaging technique. Both techniques have shown to be sensitive in measuring morphological and structural changes in skeletal muscle and the spinal cord.

저강도 초음파가 흰쥐 대퇴골 골절치유와 TGF-$\beta$1의 발현에 미치는 영향 (The Effects of Low-intensity Ultrasound on TGF-$\beta$1 Expression and Healing of Rat Femur Fracture)

  • 남기원
    • The Journal of Korean Physical Therapy
    • /
    • 제21권4호
    • /
    • pp.97-102
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the effects of low intensity pulsed ultrasound on TGF-$\beta$1 expression and healing of rat femur penetrating fractures. Methods: Rats were anesthetized with ketamine and xylazine. Using aseptic technique, we exposed the lateral right femoral diaphysis with removal of the periosteum. We made one hole along its long axis with an electrically-driven 1.8 mm diameter drill bit. Postoperatively, rats were divided into two groups (a control group, n=15; an experimental group, n=15). The experimental group was treated with low intensity pulsed ultrasound (pulse rate: 1:4, 0.5 W/$cm^2$, 10 minutes, 1 time per day) for 3 weeks. The control group was treated with sham ultrasound (with the US unit turned off). Results: The experimental group achieved more callus formation and TGF-$\beta$1 expression than the control group at the $7^{th}$, $14^{th}$ and $21^{st}$ days after low intensity pulsed ultrasound treatment. Conclusion: This study suggests that low intensity pulsed ultrasound facilitates bone fracture repair, possibly via increased TGF-$\beta$1 expression.

  • PDF

당뇨병성 말초혈관병증에서 항혈소판제의 효과: 발목상완지수 및 맥파전달속도를 통한 비교 (Effect of Antiplatelets in Diabetic Peripheral Vasculopathy: Comparison by Ankle-Brachial Index and Peak Wave Velocity)

  • 박세진
    • 대한족부족관절학회지
    • /
    • 제18권4호
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study is to confirm the effect of antiplatelet drugs in diabetic peripheral vasculopathy in diabetic foot patients. Materials and Methods: We designed a retrospective study in diabetic foot patients with diabetic peripheral vasculopathy. From October 2007 to December 2013, 278 cases in 139 patients who took antiplatelet drugs over at least a six-month period were included in this study. We categorized these patients according to the type of drug used. The efficacy of antiplatelet drugs was evaluated using anklebrachial index (ABI) and pulse wave velocity (PWV). Results: Only the aspirin group showed a statistically significant increase of ABI after antiplatelet therapy ($1.10{\pm}0.12$ to $1.12{\pm}0.11$). In addition, only the cilostazol group showed a statistically significant decrease of PWV after antiplatelet therapy ($1,701.20{\pm}396.56$ to $1,627.42{\pm}324.98$). Conclusion: Aspirin and cilostazol may be used in treatment of diabetic peripheral vasculopathy, whereas dual antiplatelet therapy with aspirin and clopidogrel has no specific benefits in diabetic peripheral vasculopathy.

인영촌구 비교맥진을 통한 간화 담화성 이명환자 침 치료4례 (Four case of Liver fire.Phlegm-fire Tinnitus treated by Axupuncture Therapy with the Inyeong.the chon spot comparison pulse diagnosis)

  • 원영호;소웅룡;이순호;김제관
    • 한방안이비인후피부과학회지
    • /
    • 제15권2호
    • /
    • pp.183-189
    • /
    • 2002
  • Tinnitus is usually due to insufficiency of Kidney-essence, asthenia of the Spleen and Stomach, diseases caused by exogenous pathogenic factor, Liver fire(肝火) by severe stress, Phlegm -fire(痰火) by surfeit of high caloric food and alcoholic liquor. I observed and treated four patients who had been diagnosed with tinnitus of Liver-fire(肝火) and Phlegm-fire(痰火). After I checked the Inyeong(人迎) and the chon spot(寸口), all of their Inyeong were stronger than chon spot. Unbalance of the Inyeong(人迎) and the chon spot(寸口), and symptoms of tinnitus were removed by Acupuncture therapy of three Yang meridians of the hand(手三陽) and three Yang meridians of the foot(足三陽).

  • PDF

생체신호 기반의 심신 완화를 위한 컬러테라피 조명등 (Color Therapy Lighting for Physical and Mental Relaxation based on Bio-signal)

  • 이민혜;강선경;신성윤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.660-662
    • /
    • 2022
  • COVID-19 장기화의 여파로 인해 스트레스 및 정신적 질환을 겪는 현대인이 늘어나고 있다. 최근에는 LED 조명을 이용하여 집중력 향상, 스트레스 완화, 피부관리, 수면의 질 개선 등을 위해 다양한 방법으로 컬러테라피가 연구 되고 있다. 본 논문에서는 사람의 심신 상태를 분석하기 위해 PPG(Photoplethysmogram) 센서를 이용하여 맥파를 계측하고 심박변이도를 추출한다. RGBLED와 아두이노를 이용하여 심리상태 안정에 주로 사용되는 여러 파장의 색상조명을 제작하고, 심신상태의 변화에 따라 자동으로 색상을 변경해주는 무드등 시스템을 제안한다.

  • PDF

일원배치 분산분석을 응응한 남자의 한의학적 8체질 임상특성 연구 (A Study on Men's 8-Constitutional Characteristics Using the Oneway Analysis of Variance)

  • 이상범;박영배;최경미
    • 응용통계연구
    • /
    • 제19권2호
    • /
    • pp.203-215
    • /
    • 2006
  • 최근 한의학에서는 인체를 8가지 체질로 나누는 8체질의학에 대한 관심이 높아지고 있다. 그런데 8체질은 맥진에 근거하여 판별되므로, 8체질의 판별 및 병증의 치료를 표준화시키기 위해서는 객관적인 8체질의 특성을 찾아내어 이것을 표준화시키는 일이 절실하다. 본 연구에서는 맥진을 통하여 8체질로 분류된 후 8체질 침법에 따라 치료 중인 남자 환자들의 신체적 특징과 증후 등을 설문을 통하여 문진하였다. 그리고 일원배치 분산분석법에서 유의한 문항들에 대하여 다중비교법을 이용하여 8체질 사이의 평균 차이를 표로 나타내었다. 이 분석에서 유의하게 나타난 문항들은 실제의 진단 및 치료에서 관찰되어온 8체질 특성과 잘 일치하고 있었다.

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정 (GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy)

  • 이병구;임현수;네클라 커나르
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.

비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가 (A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test)

  • 최민주;강관석;이강일
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.526-539
    • /
    • 2012
  • 본 연구에서는 기존의 방광 내압 측정의 문제점을 근본적으로 해결할 수 있는 새로운 접근법인 '초음파를 이용한 비침습적 방광 내압 측정 기술'을 제안한다. 제안된 기술은 초음파에 의한 캐비테이션 현상을 이용한다. 즉, 체외에서 조사된 고강도 초음파 펄스에 의해 방광 내에 생성된 기포의 동 특성은 방광 내압에의 영향을 받는다는 물리적인 현상에 근거한다. 본 논문에서는 초음파 방광 내압의 측정 기술의 이론적 기초를 제시하고 및 초기적인 측정 실험을 통해 실현 가능성을 입증했다. 제안된 초음파 방광 압력 측정법은 비침습적이며, 성별, 연령에 관계없이 적용 가능하고, 상시 측정이 가능하여 향후 방광 및 배뇨 장애 관련 진단 및 치료에 크게 기여할 것으로 기대된다.