• Title/Summary/Keyword: Pulse therapy

Search Result 326, Processing Time 0.025 seconds

Analysis of Output Characteristics and Frequency Variation Design for Personal High Frequency Electrical Stimulation Medical Devices (개인용 고주파 전기자극기의 주파수 가변 설계 및 출력 특성의 분석)

  • Jang, Kyeong-Wook;Leem, Ji-Hyun;Baek, Seung-Myoung;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • In this paper, personal electrical stimulation medcial devices using bioelectrical stimulating was developed. Therapy effect of RET(resistive electric transfer) was more effective than CET(capacitive electric transfer), but CET was adopted because of safety issue. Then, the optimum parameters that may be effective in thin skin or facial wrinkles was set. For example, the frequency of the pulse voltage for stimulation is 1.8[MHz], burst frequency is 7[kHz] or 400[Hz], the development of devices was to have ON/OFF control and frequency control. When burst frequency was adjusted 7[kHz], heat was generated in the electrode. The case of 400[Hz] the heat was little generated. The microcontroller ATmega128-based experimental results show that the proposed personal high frequency electrical stimulation devices can be applied to medical equipment using therapy effect successfully.

Muscular Adaptations and Novel Magnetic Resonance Characterizations of Spinal Cord Injury

  • Lim, Woo-Taek
    • Physical Therapy Korea
    • /
    • v.22 no.2
    • /
    • pp.70-80
    • /
    • 2015
  • The spinal cord is highly complex, consisting of a specialized neural network that comprised both neuronal and non-neuronal cells. Any kind of injury and/or insult to the spinal cord leads to a series of damaging events resulting in motor and/or sensory deficits below the level of injury. As a result, muscle paralysis (or paresis) leading to muscle atrophy or shrinking of the muscle along with changes in muscle fiber type, and contractile properties have been observed. Traditionally, histology had been used as a gold standard to characterize spinal cord injury (SCI)-induced adaptation in spinal cord and skeletal muscle. However, histology measurements is invasive and cannot be used for longitudinal analysis. Therefore, the use of conventional magnetic resonance imaging (MRI) is promoted to be used as an alternative non-invasive method, which allows the repeated measurements over time and secures the safety against radiation by using radiofrequency pulse. Currently, many of pathological changes and adaptations occurring after SCI can be measured by MRI methods, specifically 3-dimensional MRI with the advanced diffusion tensor imaging technique. Both techniques have shown to be sensitive in measuring morphological and structural changes in skeletal muscle and the spinal cord.

The Effects of Low-intensity Ultrasound on TGF-$\beta$1 Expression and Healing of Rat Femur Fracture (저강도 초음파가 흰쥐 대퇴골 골절치유와 TGF-$\beta$1의 발현에 미치는 영향)

  • Nam, Ki-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.4
    • /
    • pp.97-102
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the effects of low intensity pulsed ultrasound on TGF-$\beta$1 expression and healing of rat femur penetrating fractures. Methods: Rats were anesthetized with ketamine and xylazine. Using aseptic technique, we exposed the lateral right femoral diaphysis with removal of the periosteum. We made one hole along its long axis with an electrically-driven 1.8 mm diameter drill bit. Postoperatively, rats were divided into two groups (a control group, n=15; an experimental group, n=15). The experimental group was treated with low intensity pulsed ultrasound (pulse rate: 1:4, 0.5 W/$cm^2$, 10 minutes, 1 time per day) for 3 weeks. The control group was treated with sham ultrasound (with the US unit turned off). Results: The experimental group achieved more callus formation and TGF-$\beta$1 expression than the control group at the $7^{th}$, $14^{th}$ and $21^{st}$ days after low intensity pulsed ultrasound treatment. Conclusion: This study suggests that low intensity pulsed ultrasound facilitates bone fracture repair, possibly via increased TGF-$\beta$1 expression.

  • PDF

Effect of Antiplatelets in Diabetic Peripheral Vasculopathy: Comparison by Ankle-Brachial Index and Peak Wave Velocity (당뇨병성 말초혈관병증에서 항혈소판제의 효과: 발목상완지수 및 맥파전달속도를 통한 비교)

  • Park, Se-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study is to confirm the effect of antiplatelet drugs in diabetic peripheral vasculopathy in diabetic foot patients. Materials and Methods: We designed a retrospective study in diabetic foot patients with diabetic peripheral vasculopathy. From October 2007 to December 2013, 278 cases in 139 patients who took antiplatelet drugs over at least a six-month period were included in this study. We categorized these patients according to the type of drug used. The efficacy of antiplatelet drugs was evaluated using anklebrachial index (ABI) and pulse wave velocity (PWV). Results: Only the aspirin group showed a statistically significant increase of ABI after antiplatelet therapy ($1.10{\pm}0.12$ to $1.12{\pm}0.11$). In addition, only the cilostazol group showed a statistically significant decrease of PWV after antiplatelet therapy ($1,701.20{\pm}396.56$ to $1,627.42{\pm}324.98$). Conclusion: Aspirin and cilostazol may be used in treatment of diabetic peripheral vasculopathy, whereas dual antiplatelet therapy with aspirin and clopidogrel has no specific benefits in diabetic peripheral vasculopathy.

Four case of Liver fire.Phlegm-fire Tinnitus treated by Axupuncture Therapy with the Inyeong.the chon spot comparison pulse diagnosis (인영촌구 비교맥진을 통한 간화 담화성 이명환자 침 치료4례)

  • Weon, Young-Ho;So, Woong-Ryong;Lee, Sun-Ho;Kim, Jae-Gwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.183-189
    • /
    • 2002
  • Tinnitus is usually due to insufficiency of Kidney-essence, asthenia of the Spleen and Stomach, diseases caused by exogenous pathogenic factor, Liver fire(肝火) by severe stress, Phlegm -fire(痰火) by surfeit of high caloric food and alcoholic liquor. I observed and treated four patients who had been diagnosed with tinnitus of Liver-fire(肝火) and Phlegm-fire(痰火). After I checked the Inyeong(人迎) and the chon spot(寸口), all of their Inyeong were stronger than chon spot. Unbalance of the Inyeong(人迎) and the chon spot(寸口), and symptoms of tinnitus were removed by Acupuncture therapy of three Yang meridians of the hand(手三陽) and three Yang meridians of the foot(足三陽).

  • PDF

Color Therapy Lighting for Physical and Mental Relaxation based on Bio-signal (생체신호 기반의 심신 완화를 위한 컬러테라피 조명등)

  • Lee, Min-Hye;Kang, Sun-kyoung;Shin, Seong-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.660-662
    • /
    • 2022
  • Due to the prolonged aftermath of COVID-19, the number of modern people suffering from stress and mental illness is increasing. Recently, various methods of color therapy are being studied using LED lighting to improve concentration, relieve stress, manage skin, and improve sleep quality. In this paper, pulse waves are measured and heart rate variability is extracted using a PPG (Photoplethysmogram) sensor to analyze a person's mental and physical state. Using RGBLED and Arduino, we propose a mood lighting system that automatically changes colors according to changes in mental and physical conditions by producing color lighting of various wavelengths, which are mainly used to stabilize the mental state.

  • PDF

A Study on Men's 8-Constitutional Characteristics Using the Oneway Analysis of Variance (일원배치 분산분석을 응응한 남자의 한의학적 8체질 임상특성 연구)

  • Rhee Sang-Beom;Park Young-Bae;Choi Kyung-Mee
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.2
    • /
    • pp.203-215
    • /
    • 2006
  • In Oriental Medicine, there have been a number of researches in 8-Constitution medicine which classifies human bodies into one of 8 categories. Since the diagnosis of 8-Constitution depending on pulse types is often subjective, standardization of the diagnosis and therapy requires objective characteristics of 8 constitutions. A questionnaire of 80 items about personal symptoms were given to patients while they were classified into one of 8 constitutions based on their pulse types and responses to constitution-based acupuncture therapy. One-way analysis of variance and Duncan's multiple comparison test were used to verify the significant items. Most of the significant items in this study coincided with supposed-to-be clinical characteristics of 8-constitutions.

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy (GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정)

  • Lee, Byung Koo;Lim, Hyun Soo;Kenar, Necla
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.