• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.029 seconds

Comparison of Electrodermal Activity between Hypertensive and Non-hypertensive Subject in Health Screening Population (건강검진자 대상 고혈압 유무에 따른 피부전기활동성 비교 연구)

  • Kim, Young Eun;Kim, Chul;Yea, Sang Jun;Yang, Chang Sop;Song, Mi Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.847-852
    • /
    • 2013
  • The aim of this study was to investigate the difference of electrodermal activity between the hypertensive and non-hypertensive subjects. A total 161 subjects who visited a hospital for health check ups from August 2011 through November 2011 and from September 2012 through November 2012 were included in this study. We divided the subjects into two groups by blood pressure, hypertension group(81 patients) and non-hypertension group(180 subject). Then we compared electrodermal activity between two groups by using the autonomic bioelectric response device model CP-6000A. The data was analyzed by independent t-test and logistic regression. In this study, there was a significant difference in electrodermal activity(the mean absolute value of positive, negative pulse conductivity) between hypertensive and normotensive group in t-test and electrodermal activity showed the significant influence on the prevalence risk of hypertension with age, body mass index and dyslipidema in binominal logistic regression. In conclusion, hypertensive patients had high level of electrodermal activity compared with normotensive subjects and this finding suggests that electrodermal activity which is explained excess tendency in Korean traditional medicine could be used for diagnosis in hypertension patients at Korean traditional medical clinic.

A Study of High Temperature Filtration Performance Test on Low Density Cylindrical Ceramic Filters (저밀도 원통형 세라믹 필터의 고온 여과 성능시험 연구)

  • 이동섭;홍민선;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.213-222
    • /
    • 2001
  • Cylindrical type ceramic filers, that is 60 O.D$\times$10t$\times$600L and 60 O.D$\times$10t$\times$1,000L were manufactured by vacuum forming processes using ceramic ray materials. For cylindrical type ceramic filters, porosity and bulk density were measured for, 80 to 90% and 0.3 to 0.4 g/㎤, respectively at uniform pore size of 41 to 45${\mu}{\textrm}{m}$. Bench scale candle filters (60$\psi$ $\times$10t$\times$600L) were tested using different dusts collected from many industries including chemical processing, glass processing and metal manufacturing pants. Collection efficiencies found out to range from 99.87% to 99.90%, while resistance coefficients from 1.1$\times$10(sup)11/$m^2$ to 1.7$\times$10(sup)11/$m^2$ . Full scale low density ceramic filters (60$\psi$ $\times$10t$\times$1,000L) were also tested at 1 atm, $600^{\circ}C$ to reveal the filtration efficiency, conditioning, and resistance coefficients using two different types of dust as chemical processing and metal refined processing. Darcys law resistance coefficients were measured to range 1.44$\times$10(sup)11/$m^2$ to 2.74$\times$10(sup)11/$m^2$, and collection efficiencies on the range 99.84 to 99.96%, Finally, results of long term performance test showed that filters were conditioned after 170hrs. Experimental conditions for effective filtration were examined under the condition 10 cm/sec face velocity, 3kg/$\textrm{cm}^2$ pulsing pressure, 5 min filtration cycle, and 300msec pulse opening time.

  • PDF

An Experimental Study on Variations of Exhaust Gas Temperature and Concentration with Synthetic Gas Combustion in Exhaust Manifold (배기관에서의 합성가스 연소에 따른 배기가스 온도 및 농도 변화에 관한 실험적 연구)

  • Cho, Yong-Seok;Lee, Seang-Wock;Yang, Seung-Il;Song, Chun-Sub;Park, Young-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.56-62
    • /
    • 2008
  • A synthetic gas reformed from hydrocarbon-based fuels consists of $H_2$, CO and $N_2$. Hydrogen contained in the synthetic gas is a very useful species in chemical processes, due to its wide flammability range and fast burning speed. The ESGI (Exhaust Synthetic Gas Injection) technology is developed to shorten the light-off time of three way catalysts through combustion of the synthetic gas in the exhaust manifold during the cold start period of SI engines. Before the ESGI technology is applied to the test engine, the authors set a test rig that consists of gas temperature and composition controllers, an exhaust pulse generator and an exhaust manifold with a visualization window, in order to optimize the point and conditions of injection of the synthetic gas. Through measuring burned gas temperatures and taking photographs of synthetic gas combustion at the outlet of the exhaust manifold, the authors tried to find the optimal injection point and conditions. Analysis of burned gas composition has been performed for various $O_2$ concentrations. As a result, when the synthetic gas is injected at the port outlet of the cylinder No. 4 and $O_2$ concentration exceeds 4%, combustion of the synthetic gas is strong and effective in the exhaust manifold.

Strength and Non-fracture Test of Ready Mixed Concrete Using Polypropylene Fiber (폴리프로필렌 섬유를 혼입한 레미콘의 강도 및 비파괴 시험)

  • Nam, Ki-Sung;Youn, Dong-Chae;Yoon, Yeo-Hoon;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.403-406
    • /
    • 2003
  • This study is performed to evaluate the strength and nan-fracture test of the ready mixed concrete(RMC) using polypropylene. The slump is reached in $8{\pm}2cm$ of each RMC using polypropylene or without polypropylene, air content is reached in $4.5{\pm}1.5%$, the chloride content is below $0.3kg/m^3$. The compressive strength of RMC not using polypropylene is appeared over $210kgf/cm^2$ at the curing age 7 days and $239kgf/cm^2$ at the curing age 28 days. The compressive strength of RMC using polypropylene is appeared over $188kgf/cm^2$ at the curing age 7 days and $238kgf/cm^2$ at the curing age 28 days. The dynamic modulus of elasticity of RMC not using polypropylene is appeared over $298{\times}10^3kgf/cm^2$ at the curing age 7 days and $342{\times}10^3kgf/cm^2$ at the curing age 28 days. The RMC using polypropylene is appeared over $284{\times}10^3kgf/cm^2$ at the curing age 7 days and $238{\times}10^3kgf/cm^2$ at the curing age 28 days. The pulse velocity of RMC not using polypropylene is appeared over 4,198m/s at the curing age 7 days and 4,382m/s at the curing age 28 days. The RMC using polypropylene is appeared over 4,182m/s at the curing age 7 days and 4,342m/s at the curing age 28 days.

  • PDF

Pain Reducing Effects of Dextrose-coated Pacifier on Venipuncture in Premature Infants (포도당 코팅 노리개 젖꼭지 제공이 미숙아의 정맥주사 시 통증 반응에 미치는 효과)

  • Seo, Jung-Suk;Kwon, In-Soo;Kim, Hee;Jung, Young-Ran;Jo, Sung-Jin;Hwang, Ju-Young;Kang, Hyun-Sun
    • Korean Parent-Child Health Journal
    • /
    • v.13 no.2
    • /
    • pp.78-85
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the pain reducing effects of the dextrose-coated pacifier on venipuncture in premature infants. Methods: The design of this study is a nonequivalent control group pretest-posttest design and a crossover trial. The analysed cases were 40 premature infants (20 in experimental group and 20 in control group) in neonatal intensive care unit of a University Hospital, Gyeongnam Province, Korea. The data were collected from April to October, 2009. The experimental treatment was carried out nursing 20% dextrose-coated pacifier on venipuncture for IV injection. The instruments were $O_2$ saturation and heart rate on pulse oxymeter monitor to measure physiologic pain responses, and NIPS to measure behavioral pain responses. Collected data were analyzed with $x_2$ test, t-test using SPSS program. Results: The effects of the 20% dextrose-coated pacifier were found in the physiologic (only heart rate) and behavioral pain response on venipuncture. Conclusion: These finding is suggested that the dextrose-coated pacifier could be an effective nursing intervention for reducing pain on venipuncture in premature infants.

  • PDF

A Study on Home Nursing Care Requirement and Activities of Daily Life Among the Elderly at Home (재가노인의 가정간호요구도 및 일상생활능력에 관한 연구)

  • 조선화;김병성;김공현;박형종
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.125-145
    • /
    • 1994
  • The objectives of this study were to characterize the health status, the requirement of home nursing care, and dependency of daily life of the elderly so that the result could be used to provide basic data necessary for establishing home nursing care practices. The study subjects were 249 elders over 65 years old who resided at home in low income areas of three districts in Pusan. The field survey was conducted from December 27, 1993 through January 27, 1994, with a structured questionnaire. Statistical analysis was done by X²-test and Student's T-test using SPSS/PC/sup +/ program. The result were as follows; 1. Alcohol drinking rate was 50.0% for men and 27.7% for women, and cigarette smoking rate was 77.8% for men and 27.1% for women. 92.9% of elders aged 65-75 exercised regularly as compared to 81.9% of elders aged 75 and over(p<0.05). 2. 63.9% of male and 85.9% of female elders had chronic diseases showing singnificant differences(p<0.01), and both sexes had 1.7 kinds of chronic diseases in average; musculoskeletal diseases were the most common in 25.7%, while 6.8% of the elderly had cardiovascular diseases. 3. Partially movable elderly was 6.9% for men and 6.8% for woman, showing 47.1% of causes being cerebrovascular accidents. 4. The home nursing requirement was the highest for medication(66.3%), intramuscular injection(53.8%), and measurement of blood pressure·body·temperature·pulse rate(47.0%). 5. Among Physical Activities of Daily Life, bathing(10.4%) and movement(4.0%) showed high dependency rates, and among Instrumental Activities of Daily Life, phone calling(25.3%), shopping(24.5%), going out by bus(22.5%) showed high dependency rates. 6. For five categories of home nursing showing high requirements such as physical health examination, blood pressure·temperature·pulas rate measurements, medication, and intravascular injection, the requirements were different by age groups, education, and marital status(p<0.05).

  • PDF

Optimized Design and Manufacture of Wideband Pulsed Gamma-ray Sensors (광대역 펄스감마선 탐지센서 최적화 설계 및 제작)

  • Jeong, Sang-hun;Lee, Nam-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.223-228
    • /
    • 2017
  • In this paper, we are proposing an optimal design of wideband pulsed type gamma-ray sensors. These sensors were manufactured based on the design results and after word electrical properties were analyzed. The sensor input parameters were derived on the basis of pulsed gamma-ray spectrum and time-dependent energy rate, and the output current which were derived on the basis of the sensor sensitivity control circuit. Pulsed gamma-ray sensors were designed using the TCAD simulators. The design results show that the optimal Epi layer thickness is 45um with the applied voltage 3.3V and the diameter is 2.0mm. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. The fabricated sensor was a leakage current, 12pA at voltage -3.3V and fully depleted mode at voltage -5V. A test result of pulsed radiation shows that the sensor gives out the optimal photocurrent.

Development and Ergonomic Evaluation of Spring and Autumn Working Clothes for Livestock Farming Workers

  • Kim, Insoo;Lee, Kyung-Suk;Seo, Min-Tea;Chae, Hye-Seon;Kim, Kyung-Su;Choi, Dong-Phil;Kim, Hyo-Cher
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.343-359
    • /
    • 2016
  • Objective:In this study, we designed working clothes for livestock farmers to wear in spring and autumn to improve their work efficiency, conducted a physiological test on their performance, and evaluated their comfort. Background: In recent years, livestock farming in Korea has expanded, yet farmers' safety and sanitation levels remain low in hazardous environments that include organic dust, toxic gas, and heat stress, as well as the risk of accidents. Furthermore, most livestock farmers wear ordinary or dust-resistant clothes that are unsuitable for rearing livestock and compromise their safety and health. Thus, it is important to design specialized working clothes for livestock farmers that are comfortable and that minimize their health and safety risks. Method: To this end, we examined the literature on livestock (poultry, swine, and cattle) farmers' safety and sanitation issues, designed appropriate working clothes, and tested them in terms of sensory feel, physiological response, and subjective comfort. Results: The respondents expressed satisfaction with the new working clothes. The results of a physiological test showed a decline in temperature and humidity inside the clothes, a lower pulse rate, and a lower oxygen intake compared to the measurements taken when famers wore their previous working clothes. This indicates a fall in heat stress and fatigue, which was mostly consistent with the results of the assessment of subjective comfort. Conclusion: The results of the analysis show an improvement in the comfort of the new working clothes compared to the dust-resistant clothes that are widely worn. Based on this study, the new working clothes need to be further tested and evaluated to improve the design. Application: This study is expected to contribute to designing better working clothes for livestock farmers.

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

Design and Performance Evaluation of the Vibration Absorber of Vertical Direction Using Numerical Simulation and Shock Test (수치적 시뮬레이션과 충격 시험을 통한 수직방향 진동절연 완충기 설계 및 성능 평가)

  • Park, Sang-Gil;Bang, Seung-Woo;Kwon, O-Cheol;Lee, Jung-Youn;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.558-563
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc' spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock Isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.