• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.028 seconds

Compensation of Addressing Time at High Temperature in ac PDP.

  • Choi, Joon-Young;An, Jung-Soo;Kim, Hun-Hee;Lee, Ho-Jun;Lee, Hea-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.164-170
    • /
    • 2004
  • Misfiring is often observed during the high temperature quality assurance test of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases time lag in address discharge, and results in increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

  • PDF

Effects of Aromatherapy on Blood Pressure, Pulse, Fatigue, and Sleep for Patients with Allergic Rhinitis (알레르기성 비염 환자에게 적용한 향기요법이 혈압, 맥박, 피로 및 수면에 미치는 효과)

  • Song, Min-Sun;Suh, Young-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.12 no.1
    • /
    • pp.16-23
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effects of aromatherapy on blood pressure, pulse, fatigue and sleep for patients with allergic rhinitis admitted at a hospital specialized in an oriental medicine. Methods: This research was a single-group pretest-posttest design. Data were collected at admission and discharge from May to December, 2009. The patients selected were received an aroma inhalation therapy via nebulizer with a 2% diluted oil mixture of eucalyptus and peppermint with 10 cc of saline solution in the ratio of 1:1 ones a day for 15 min in the period of 2 weeks. The data were analyzed for the descriptive statistics and paired t-test. Results: There was a statistically significant improvement on physical and psychological symptoms of fatigue and sleep with a increase in systolic blood pressure. Conclusion: Eucalyptus and peppermint blended oil aromatherapy as a sleep induction modality is an effective nursing and therapeutic intervention in conjunction with acupuncture and herbal medicine for symptoms of nasal congestion. However, further well designed research is required in evaluating the effectiveness of the types of clinically available essential oil.

A Study on the Development of Raingauge with 0.01 mm Resolution (0.01 mm 급 우량계 개발에 관한 연구)

  • Lee, Bu Yong
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.637-643
    • /
    • 2004
  • A new method of automatic recording raingauge is developed to measure rainfall with 0.01mm resolution. This use two different signals to measure rainfall more accurately compare than other raingauges. One is weight of the tipping bucket with rainfall amount and the other is pulse from tipping bucket reverse. New method applied 1 mm tipping bucket mechanism and install loadcell under tipping bucket mechanism for measuring rainfall weight. Loadcell measure weight of rainfall until 1 mm with 0.01 mm resolution and more than 1 mm than bucket reverse and pulse signal generate, after that loadcell measure weight again. The validation of new instrument was examined in the room 65 mm/hour rainfall rate total 53 mm range. There is below than 1 % error of absolute rainfall amount and 0.01 mm resolution. The field test of instrument was carried out by comparing its measured values with values recorded by weight type and standard type on June 1 2003 at Terrestrial Environmental Research Center at Tsukuba University in Tsukuba of Japan, when it has recorded total amount of 40.58 mm rainfall by standard raingauge and new raingauge recorded 41.032 mm. Same rainfall intensity pattern observed in field observation with weight type raingauge. Rainfall intensity between weight type and Lee-A type raingauge reached 0.9947 correlation in 3 minute average.

The Development of Clutch Control for Manual Transmission Vehicle based on Stepping Motor (스탭핑 모터에 의한 수동변속기 차량의 클러치 제어 개발에 관한 연구)

  • Park, Young-Kug;Park, Joon-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3849-3855
    • /
    • 2012
  • This paper describes a control algorithm and test results of an automated manual transmission clutch actuated by a stepping motor. The control algorithm extracts driver's demand from CAN signals and decides the exact timing to engage or disengage the clutch based on the demand. A pulse signal is generated to drive the clutch and the travel of the clutch can be calculated by accumulating the pulse signal. An auto code generation method was introduced in implementing the control logic to the micro-processor of the prototype controller and a series of basic tests were carried out to validate its performance.

Bending Properties of the Flexible BMNO (Bi2Mg2/3Nb4/3O7) Capacitor Using Graphene Electrode (그래핀 전극을 이용한 유연한 BMNO (Bi2Mg2/3Nb4/3O7) 캐패시터의 굽힘 특성)

  • Song, Hyun-A;Park, Byeong-Ju;Yoon, Soon-Gil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.387-391
    • /
    • 2012
  • Graphene was fabricated onto Ni/Si substrate using a rapid-thermal pulse CVD and they were transferred onto the Ti/PES flexible substrate. For top electrode applications of the BMNO dielectric films, graphene was patterned using a argon plasma. Through an AFM image and a leakage current density of the BMNO films grown onto various bottom electrodes before and after bending test, BMNO films grown onto the graphene bottom electrode showed no change of the microstructure and the leakage current density after the bend.

Design of Path Tracking Controller Based on Thrusters for the Lunar Lander Demonstrator (달 착륙선 지상시험모델의 경로 추종을 위한 추력기 기반 제어기 설계)

  • Kim, Kwang-Jin;Lee, Jeong-Sook;Lee, Sang-Chul;Ko, Sang-Ho;Rhyu, Dong-Young;Ju, Gwang-Hyeok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.4
    • /
    • pp.37-43
    • /
    • 2011
  • Lunar exploration program has been prepared with the aim of launch in the 2020's. As part of it, a lunar lander demonstrator has been developed which is the model for verifying all the system, such as structure, propulsion and control system before launch to deep space. After verifying all the system, the demonstrator will be evaluated by flight test. This paper deals with path tracking controller based on thrusters for the demonstrator. For this, first we derive equations of motion according to the allocation of thrusters and design the path tracking controller. The signal generated from the controller is continuous so PWPF(Pulse-Width Pulse-Frequency) modulator is adopted for generating on/off signal. Finally MATLAB simulation is performed for evaluating the path tracking ability and the final landing velocity.

Effects of Stimulation Conditions and Waveforms on Muscle Contractile Characteristics

  • Song Tongjin;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study was designed to apply the stimulation system developed in our laboratory to investigate how the stimulation conditions affect the muscle contractile characteristics in the isometric condition as well as during the FES standing/walking. Four paraplegic and ten healthy subjects participated in this study, and their knee extensors were voluntary contracted or electrically stimulated to measure the muscle force and the fatigue index for different waveforms of the pulse train. We also investigated different combinations of the electrode positions during standing/walking. It was confirmed that continuous and high-frequency stimulation causes faster fatigue than intermittent and low-frequency stimulation. Fatigue resistance was higher around the optimal muscle length than at a stretched position in healthy subjects, whereas the opposite was observed in paralyzed subjects. The paired t-test results with the level of significance at 0.01 indicated that the sinusoidal waveform generated the largest torque among the four typical waveforms. Although statistically not very significant, the sinusoidal waveform also generated, in general, the highest fatigue resistance at an intensity level below the supramaximal stimulation. One of the paraplegic subject who participated in the standing/walking program can now stand up for 1 minute and 50 seconds with the knee extensors, and walk for about 5 minutes at the speed of 12m/sec.

Glottal Weighted Cepstrum for Robust Speech Recognition (잡음에 강한 음성 인식을 위한 성문 가중 켑스트럼에 관한 연구)

  • 전선도;강철호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.78-82
    • /
    • 1999
  • This paper is a study on weighted cepstrum used broadly for robust speech recognition. Especially, we propose the weighted function of asymmetric glottal pulse shape. which is used for weighted cepstrum extracted by PLP(Perceptual Linear Predictive) based on auditory model. Also, we analyze this glottal weighted cepstrum from the glottal pulse of glottal model in connection with the cepstrum. And we obtain speech features analyzed by both the glottal model and the auditory model. The isolated-word recognition rate is adopted for the test of proposed method in the car moise and street environment. And the performance of glottal weighted cepstrum is compared with both that of weighted cepstrum extracted by LP(Linear Prediction) and that of weighted cepstrum extracted by PLP. The result of computer simulation shows that recognition rate of the proposed glottal weighted cepstrum is better than those of other weighted cepstrums.

  • PDF

Relationship between Red Pepper Intake, Capsaicin Threshold, Nutrient Intake, and Anthropometric Measurements in Young Korean Women (젊은 한국여성에서 붉은고추의 섭취량, 캡사이신 역치, 영양소 섭취량 및 신체계측치간의 관련성)

  • Kim Seok-Young;Park Gyeong-Min
    • Journal of Nutrition and Health
    • /
    • v.38 no.1
    • /
    • pp.76-81
    • /
    • 2005
  • The effects of the amount of red pepper intake per a day on the capsaicin threshold, nutrient intake, and anthropo-metric measurements were investigated in 100 female students of university. Three 24-hour recalls were performed to estimate usual nutrient and red pepper intake of free-living participants. The solutions containing capsaicin at concentration of 0.05, 0.1, 0.2, 0.3, 0.4, 0.5ppm used for the evaluation of hot-taste detection threshold. Subjects were asked to recognize the burning sensation after tasting l0ml of each test solution in ascending order of capsaicin concentrations. Mean intake of red pepper was 4.6 g/d and the capsaicin threshold was 0.27 ppm. The detection threshold for capsaicin was correlated with the amount of pepper intake per a day. Red pepper intake was correlated with energy, protein, lipid, carbohydrate, Iron, vitamin A, vitamin B$_2$ niacin, and vitamin E intakes. However, it was not correlated with intake of calcium, vitamin B$_1$ or vitamin C. The red pepper intake was negatively correlated with fat mass and waist girth and the capsaicin threshold was also negatively correlated with pulse. In conclusion, red pepper intake was associated with nutrient intake and capsaicin threshold whereas it was negatively correlated with fat mass and waist girth.

Analysis of Simultaneous Generation Mechanism of P/S Waves with the PZT Piezoelectric Ceramics (PZT압전 세라믹스의 종$\cdot$횡파 동시 발생 기구의 해석)

  • Kim, Yeon-Bo;Roh, Yong-Rae;Nam, Hyo-Duk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 1995
  • Most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigated the mechanism of dual mode transducers that generates both of the longitudinal and shear waves simultaneously with a single PZT element. A piezoelectric ceramic PZT has the hexagonal 6mm crystal symmetry, after poling. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves equally strongly. The results are verified by checking the impedance variation of the element with Finite Element Methods, and checking the wave form by pulse-echo test simulation. Validity of the theoretical calculation is verified through experiments.

  • PDF