• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.029 seconds

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

A Study on the Wear Resistance and Modification Condition for Laser Surface Modified Steel (레이저 표면개질강의 개질조건과 마멸저항에 관한 연구)

  • 옥철호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.332-338
    • /
    • 1999
  • Surface hardening of plain carbon steel (SM$%C) by Laser are usually much finer and stronger than those of the base metals. The present study was undertaken to investigate the wear resistance and a processing parameters such as, power density, pulse width, defocusing distance, and molten depth for surface modification of plain carbon steel. The wear test was carried out under experimental condition using the wear test device, and in which the annular surfaces of wear test specimens as well as mating specimen of alumina ceramics(Al2O3) was rubbed in dry sliding condition. It is shown that molten depth and width depend on defocusing distance. The wear loss on variation of sliding speed was much in lower speed range below 0.2m/sec and in higher speed range above 0.7m/sec, but wear loss was little in intermediate speed range. It depends on oxidation speed and wear speed.

  • PDF

Laser hardening and Wear Characteristics of Surfaces hardening steel by YAG LASER (′YAG 레이저에 의한 표면경화강의 레이저 경화와 마멸특성)

  • 옥철호;서영백;조연상;배효준;박흥식;전태옥
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.63-70
    • /
    • 1999
  • Surface hardening of plain carbon steel (SM45C) by Laser are usually much finer and stronger than those of the base metals. The present study was under taken to investigate the wear resistance and a processing parameters such as, power density, pulse width, defocusing distance, and molten depth for surface modification of plain carbon steel. The wear test was carried out under experimental condition using the wear test device, and in which the annular surfaces of wear test specimens as well as mating specimen of alumina ceramics($Al_2O_3$) was rubbed in dry sliding condition. It is shown that molten depth and width depend on defocusing distance. The wear loss on variation of sliding speed was much in lower speed range below 0.2m/sec and in higher speed range above 0.7m/sec, but wear loss was little in intermediate speed range. It depends on oxidation speed and wear speed.

  • PDF

The Effects of Foot Massage on Anxiety and Sleep Satisfaction Response in Preoperative Patients Undergoing Abdominal Surgery (발마사지가 복부수술 전 환자의 불안과 수면만족도에 미치는 효과)

  • Kim, Geum-Ran;Oh, Sang-Eun
    • Journal of Home Health Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.108-114
    • /
    • 2009
  • Purpose: This study utilized a nonequivalent control group pre-post test design to test the effects of foot massage on anxiety and sleep satisfaction response in preoperative patients undergoing abdominal surgery. Method: There were 40 subjects in the study (20 in the experimental group and 20 in the control group). The experimental group received foot massage once a day for 2 days before their operation. Data were analyzed with descriptive statistics including mean, percentage, Chi-square, and t-test. Results: There were significant differences between experimental group and control group in the level of the state anxiety, pulse rate, and sleep satisfaction. Conclusions: Foot massage was effective in reducing anxiety and improving sleep satisfaction in abdominal surgical patients before their operation. Thus, foot massage may be used as an independent nursing intervention. This intervention can be performed anywhere, requires no special equipment, is noninvasive, and does not interfere with patients' privacy.

  • PDF

Measurement of Crack Depth inside Mortar using Ultrasonic Test (초음파 검사를 이용한 모르타르 내 균열깊이 측정)

  • Kim, Dae-You;Rhim, Hong-Chul;Cho, youn-jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.81-82
    • /
    • 2016
  • Cracks are inherent to concrete by its nature. The various size and shape of cracks induce deterioration of reinforced concrete structures including nuclear power plants. The wider and deeper the crack is, the concrete structures are more vulnerable to carbonization. Thus, it is essential to develop a reliable measurement technique of cracks inside concrete. In this study, an ultrasonic test method is applied to the crack measurements. The results can be used for evaluation of existing reinforced concrete structures.

  • PDF

Application of Thin-Walled Tubes Using Guided Wave (유도초음파를 이용한 대구경 배관 적용에 관한 연구)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.58-65
    • /
    • 2008
  • A method to test thin-walled tubes by guided ultrasonic wave is reported. The principle is that applicate two types of axially symmetric ultrasonic tube modes and "longitudinal" modes with particle displacement, which is coupled in axial and radial directions for transverse failures and torsional modes, oscillating in the circumferential direction only, for longitudinal failures. Both types of modes propagate along the tube in the axial direction. Therefore, a pulse-echo technique is possible. The pulses are excited and received at one end of the tube without contact electro-dynamic transducers. As soon as the tubes is put into a transducer coil at one end, the test of the whole tube can be accomplished in a few milliseconds. It is not necessary to rotate and transport the tubes during the test.

  • PDF

Model Test of Pulse Powered Underreamed Anchors (펄스방전 확공형 앵커의 모형시험)

  • Kim, Nak-Kyung;Ju, Yonh-Sun;Kim, Sung-Kyu;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1007-1013
    • /
    • 2008
  • In this study, a series of scaled model test were carried out in order to find factors that influence the ultimate load of underreamed anchors. Model anchors were made of arcril and 3cm in diameter. Series of tests were performed with various conditions such as density of soil, diameter of bulb, and number of bulb. Type of soil was Jumunjin sand and relative density varied 40%, 60%, 80%.

  • PDF

A Study on Fabrication and Characteristics of PZT Probe for Nondestructive Test (비파괴 검사를 위한 PZT 탐촉자의 제작 및 특성에 관한 연구)

  • 김철수;정규원;송준태
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.613-619
    • /
    • 1998
  • Ultrasonic probes of 400kHz, 1MHz were fabricated using PZT-5Z plates. Epoxy was used for backing layer materials onthe plates. Nondestructive Test was carried using these probes. Pulse lobe width of impulse response was reduced 15.4% compare 1MHz with 400kHz and 96.6% compare 3MHz with 400kHz. The attenuation in aluminum was 2.05[dB/m] at 400kHz, 4/91[dB/m] at 1MHz, 7.35[dB/m] at 3HMz. Hole detection error of the first hole was 22.4% at 1HMz, 9.% at 3HMz, The second hole 11.6% at 1HMz, 4.7% at 3HMz. In the result of experiment of the hole detection error and resolution, 3HMz probe was the best among them.

  • PDF

Design on a new oil well test shock absorber under impact load

  • Wang, Yuanxun;Zhang, Peng;Cui, Zhijian;Chen, Chuanyao
    • Structural Engineering and Mechanics
    • /
    • v.28 no.3
    • /
    • pp.335-352
    • /
    • 2008
  • Continuous operation of test and measurement is a new operating technique in the petroleum exploitation, which combines perforation with test and measurement effectively. In order to measure the original pressure of stratum layer exactly and prevent testing instrument from being impaired or damaged, a suitable shock absorber is urgently necessary to research. Based on the attempt on the FEM analysis and experiment research, a new shock absorber is designed and discussed in this paper. 3D finite element model is established and simulated accurately by LS-DYNA, the effect and the dynamic character of the shock absorber impact by half sinusoidal pulse force under the main lobe frequency are discussed both on theoretics and experiment. It is shown that the new designed shock absorber system has good capability of shock absorption for the impact load.

EVALUATION OF NONDESTRUCTIVE TESTS ANALYSIS TO ESTIMATE INPLACE STRENGTH OF CONCRETE

  • Parviz Ghoddousi;Mohsen Tadayon;Pedram H. Mojarad
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.672-680
    • /
    • 2005
  • There are a lot of reasons to use In-place tests. Construction schedules often require that operations such as form removal, post-tensioning, termination of curing, and removal of reshores be carried out as early as possible. To enable these operations to proceed safely as soon as possible requires the use of reliable in-place tests to estimate the in-place strength. In-place test results are not reliable for engineering judgment. These results should be interpreted and correlated to standard compressive strength, based on the test method. In this paper some of these test procedures and their limitations are discussed. In this study we will go on for Rebound number, Pullout, Ultrasonic pulse velocity, and Cast-in-place cylinder methods which are most useful methods in the Asia.

  • PDF