• Title/Summary/Keyword: Pulse survey

Search Result 94, Processing Time 0.034 seconds

Rare Imaging of Fat Embolism Seen on Computed Tomography in the Common Iliac Vein after Polytrauma

  • Lee, Hojun;Moon, Jonghwan;Kwon, Junsik;Lee, John Cook-Jong
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.103-106
    • /
    • 2018
  • Fat embolism refers to the presence of fat droplets within the peripheral and lung microcirculation with or without clinical sequelae. However, early diagnosis of fat embolism is very difficult because the embolism usually does not show at the computed tomography as a large fat complex within vessels. Forty-eight-year-old male with pedestrian traffic accident ransferred from a local hospital by helicopter to the regional trauma center by two flight surgeons on board. At the rendezvous point, he had suffered with dyspnea without any airway obstruction sign with 90% of oxygen saturation from pulse oximetry with giving 15 L of oxygen by a reserve bag mask. The patient was intubated at the rendezvous point. The secondary survey of the patient revealed multiple pelvic bone fracture with sacrum fracture, right femur shaft fracture and right tibia head fracture. Abdominal computed tomography was performed in 191 minutes after the injury and fat embolism with Hounsfield unit of -86 in his right common iliac vein was identified. Here is a very rare case that mass of fat embolism was shown within common iliac vein detected in computed tomography. Early detection of the fat embolus and early stabilization of the fractures are essential to the prevention of sequelae such as cerebral fat embolism.

Reliability and Validity Analysis of a Standard Instrument of Diagnosis and Assessment for Spleen Qi Deficiency Pattern in Chronic Dyspepsia Patients (비기허증(脾氣虛證) 진단평가도구의 신뢰도 및 타당도 예비 평가: 만성 소화불량 환자 대상 설문지 검증 임상시험)

  • Kim, Jihye;Kim, Juyeon;Kim, Jinsung;Kim, Keun Ho
    • The Journal of Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.23-34
    • /
    • 2015
  • Objectives: This study is aimed at assessing the reliability of a standard instrument of diagnosis and assessment for Spleen Qi deficiency pattern questionnaire (SQDQ) and examining the validity of the SQDQ by comparing the pattern identification scores of different groups. Methods: We conducted a survey of 72 participants (60 patients with chronic dyspepsia and 12 healthy subjects) using self-reported questionnaire. Participants were given written consent and this study was performed under the permission of institutional review board of Kyung-Hee university Korean medicine hospital. Results: The reliability and the validity of the questionnaire were inspected. Internal consistency of the SQDQ was excellent. Construct validity analyzed by exploratory factor analysis produced 4 factors, which were selected from eigenvalues that are greater than 1.0. The factor 1, 2, 3 and 4 showed 'fatigue', 'meal', 'diagnosis' and 'figure' respectively. For most of SQDQs' items, there were significant differences observed between the Spleen Qi and the non-Spleen Qi groups. However, the 'emaciation', 'tongue diagnosis' and 'pulse diagnosis' showed no significant differences. Conclusions: The SQDQ restructured in this study may provide a fundamental questionnaire and a further study is required for a more advanced, standardized and statistically proven questionnaire.

Clinical Study of Discrimination of Sasang Constitution wi th 7-Zone-Diagnostic System(VEGA-DFM722) (7구역진단기(VEGA-DFM722)를 이용한 사상체질 판별 가능성에 대한 임상 연구)

  • Song, Beom-Yong;Kwon, Kyong-Suk;Song, Jeong-Mo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.82-93
    • /
    • 2007
  • 1. Objectives Functional medicine is a system which utilizes certain Investigative and treatment methods that are primarily oriented toward the recognition of functional disorder. The 7-zone-diagnostic system(VEGA-DFM722 and ABR-2000, etc) is a diagnostic device which applies pulse signals to predetermined bodily locations. We think that we can discriminate between Soeumin, Soyangin and Taeumin with this system. 2. Methods The subject of our study is no disease men and women who are decided the same constitution both survey of the QSCC II and diagnosis of specialist of the Sasang Constitution. All subject are 76(Soeumin(N=24), Soyangin(N=17), Taeumin(N=35)) cases. We make an analysis of a distinctive feature on the result of the VEGA-DFM722. 3. Results and Conclusions 1) Soeumin or Taeumin women had that the red bar graphs of and 1, 2 and 3 are lower than the red bar graphs of zone 4, 5, 6 and 7 in factor AA on the result of the VEGA-DFM722 with the naked eye. Soyangin or Taeumin men had that the red bar graphs of zone 1,2 and 3 are higher than the red bar graphs of tone 4, 5, 6 and 7 in factor AA on the result of the VEGA-DFM722 with the naked eye. 2) The typical discrimination between Soeumin and Soyangin showed statistical significance(p<0.05) in Factor PF 4(red bar) on the result of VEGA-DFM722.

  • PDF

An Observational Multi-Center Study Protocol for Distribution of Pattern Identification and Clinical Index in Parkinson's Disease (파킨슨병 변증 유형 및 지표 분포에 대한 전향적 다기관 관찰연구 프로토콜)

  • HuiYan Zhao;Ojin Kwon;Bok-Nam Seo;Seong-Uk Park;Horyong Yoo;Jung-Hee Jang
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Objectives: This study investigated the pattern identification (PI) and clinical index of Parkinson's disease (PD) for personalized diagnosis and treatment. Methods: This prospective observational multi-center study recruited 100 patients diagnosed with PD from two Korean medicine hospitals. To cluster new subtypes of PD, items on a PI questionnaire (heat and cold, deficiency and excess, visceral PI) were evaluated along with pulse and tongue analysis. Gait analysis was performed and blood and feces molecular signature changes were assessed to explore biomarkers for new subtypes. In addition, unified PD rating scale II and III scores and the European quality of life 5-dimension questionnaire were assessed. Results: The clinical index obtained in this study analyzed the frequency statistics and hierarchical clustering analysis to classify new subtypes based on PI. Moreover, the biomarkers and current status of herbal medicine treatment were analyzed using the new subtypes. The results provide comprehensive data to investigate new subtypes and subtype-based biomarkers for the personalized diagnosis and treatment of PD patients. Ethical approval was obtained from the medical ethics committees of the two Korean medicine hospitals. All amendments to the research protocol were submitted and approved. Conclusions: An objective and standardized diagnostic tool is needed for the personalized treatment of PD by traditional Korean medicine. Therefore, we developed a clinical index as the basis for the PI clinical evaluation of PD. Trial Registration: This trial is registered with the Clinical Research Information Service (CRIS) (KCT0008677)

Feasibility of Ocean Survey by using Ocean Acoustic Tomography in southwestern part of the East Sea (동해 남서해역에서 해양음향 토모그래피 운용에 의한 해양탐사 가능성)

  • Han, Sang-Kyu;Na, Jung-Yul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.75-82
    • /
    • 1994
  • The ray paths and travel times of sound wave in the ocean depend on the physical properties of the propagating media. Ocean Acoustic Tomography(OAT), which is inversely estimate the travel time variations between fixed sources and receivers the physical properties of the corresponding media can he understood. To apply ocean survey technology by using the OAT, the tomographic procedure requires forward problem that variation of the travel times be identified with the variability of the medium. Also, received signals must be satisfied the necessary conditions of ray path stability, identification and resolution in order for OAT to work. The canonical ocean has been determined based on the historical data and its travel time and ray path are used as reference values. The sound speed of canonical ocean in the East Sea is about 1523 m/s at the surface and 1458 m/s at the sound channel axis(400m). Sound speeds in the East Sea are perturbed by warm eddy whose horizontal extension is more than 100 km with deeper than 200 m in depth scale. In this study, an acoustic source and receiver are placed at the depth above the sound channel axis, 350 m, and are separated by 200 km range. Ray paths are identified by the ray theory methed in a range dependent medium whose sound speeds are functions of a range and depth. The eigenray information obtained from interpolation between the rays bracketing the receiver are used to simulate the received signal by convolution of source signal with the eigenray informations. The source signal is taken as a 400 Hz rectangular pulse signal, bandwidth is 16 Hz and pulse length is 64 ms. According to the analysis of the received signal and identified ray path by using numerical model of underwater sound propagation, simulated signals satisfy the necessary conditions of OAT, applied in the East Sea.

  • PDF

SEDATION PRACTICES IN DENTAL OFFICE : A SURVEY OF MEMBERS OF THE KOREAN ACADEMY OF PEDIATRIC DENTISTRY (진정요법사용에 관한 설문조사)

  • Choi, Young-Sim;Shim, Youn-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.579-588
    • /
    • 1999
  • Monitoring of patients is essential in assuring the safety of sedation in the dental office. The purpose of this study was to explore the utilization and preferences of sedation, utilization of monitoring methods, and the preparation for emergencies during sedation. Members of the Korean Academy of Pediatric Dentistry were surveyed(n=245) from 1998. 10. 1 to 1998. 12. 20 to establish current trends in the use of sedation practices and monitoring methods in Korea. Findings of the survey include: 1. Twenty nine percent of pediatric dentists use sedative agents in their practices. Seventy one percent of pediatric dentists do not use any sedative agents in their practices 2. Thirty nine percent of pediatric dentists who use sedative agents do so without monitoring devices 3. Nitrous oxide inhalation sedation was the most frequently utilized sedation method by pediatric dentists and chloral hydrate was the most frequently utilized sedative by pediatric dentists. Pulse oximeter was the most frequently utilized monitoring method during sedation in dental office. 4. Only twenty eight percent of pediatric dentists obtain the informed consent of the child's legal guardian. 5. Only sixty percent of pediatric dentists prepare for emergencies during sedation.

  • PDF

Pediatric Endoscopic Sedation in Korea: A Survey of the Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition (소아청소년 진정내시경: 대한소아소화기영양학회 학술위원회 조사 보고)

  • Ryoo, Eell;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • Purpose: The aim of this survey was to analyze the choice of sedative drugs and their side effects during pediatric endoscopic sedation in Korea. We also evaluated doctors, caretakers and patient satisfaction with the procedures. Methods: Between June 2006 and July 2006, a 16-item survey regarding current sedation practices, during one month, was mailed to 28 hospitals in Korea. The results of the survey responses were then analyzed. Results: Endoscopy performed under conscious sedation was reported in 89.0% of the responders and endoscopy under general anesthesia in 0.9% of 465 endoscopic procedures. Endoscopy under conscious sedation was performed in 89.1% for upper gastrointestinal endoscopy (GFS) and 88.1% for lower GFS. Midazolam was used for conscious sedation during the endoscopy in 84.5% of cases and propofol was used in two cases (0.5%). In addition, a bezodiazepine/opioid combination was used iin 84.6% (44 cases) for lower GFS. Patients were monitored with pulse oxymetry, EKG (91.4%) as well as automatic BP (5.1%). Transient hypoxia was the only side effect noted and was treated with supplemental oxygen (4.6%). Flumazenil was used in 2.71% of cases. The choice of sedation was made by the endoscopist (84%). The satisfaction rate for endoscopists was 68%, and for the patients and caretakers was 84% (as reported by the endoscopists). Conclusion: Midazolam was used only for the upper GFS and benzodiazepine/opioid combination was used for the lower GFS in Korea. The rate of satisfaction was relatively high and there were no significant side effects noted during the endoscopy under conscious sedation.

  • PDF

Multi-purpose Geophysical Measurements System Using PXI (PXI를 이용한 다목적 물리탐사 측정 시스템)

  • Choi Seong-Jun;Kim Jung-Ho;Sung Nak-Hun;Jeong Ji-Min
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.3
    • /
    • pp.224-231
    • /
    • 2005
  • In geophysical field surveys, commercial equipments often fail to resolve the subsurface target or even sometimes fail to be applied because they do not fit to the various field situations or the physical properties of the medium or target. We developed a geophysical measurement system, which can be easily adapted for the various field situations and targets. The system based on PXI with A/D converter and some stand alone equipment such as Network Analyzer was applied to borehole radar survey, borehole sonic measurement and electromagnetic noise measurement. The system for borehole radar survey consists of PXI, Network Analyzer, dipole antennas, GPIB interface is used for PXI to control Network Analyzer. The system for borehole sonic measurement consists of PXI, 24 Bit A/D converter, high voltage pulse generator, transmitting and receiving piezoelectric sensors. The electromagnetic noise measurement system consists of PXI, 24 Bit A/D converter, 2 horizontal component electric field sensors and 2 horizontal and 1 vertical component magnetic filed sensors. The borehole radar system has been successfully applied to detect the width of the artificial tunnel through which the borehole pass and to image buried steel pipe, while the commercial borehole radar equipment failed. The borehole sonic system was tested to detect the width of artificial tunnel and showed a reasonable result. The characteristic of electromagnetic noise was grasped at an urban area with the data from the electromagnetic noise measurement system. The system is also applied to characterize the signal distortion by induction between the electric cables in resistivity survey. The system can be applied various geophysical problems with a simple modification of the system and sensors.

Long-term Oxygen Therapy for Chronic Respiratory Insufficiency: the Situation in Korea after the Health Insurance Coverage: a Multi-center Korean Survey -Study for the Development and Dissemination of the COPD Guidelines, Clinical Research Center for Chronic Obstructive Airway Disease- (가정산소치료의 보험급여 실시 이후 처방 실태: 다기관 조사 -만성기도폐쇄성질환 임상연구센터 제3세부과제 만성기도폐쇄성질환 진료지침 개발/보급 연구-)

  • Park, Myung Jae;Yoo, Jee-Hong;Choi, Cheon Woong;Kim, Young Kyoon;Yoon, Hyoung-Kyu;Kang, Kyung Ho;Lee, Sung Yong;Choi, Hye Sook;Lee, Kwan Ho;Lee, Jin Hwa;Lim, Sung-Chul;Kim, Yu-Il;Shin, Dong Ho;Kim, Tae Hyun;Jung, Ki-Suck;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.2
    • /
    • pp.88-94
    • /
    • 2009
  • Background: From November 2006, The national health insurance system in the Republic of Korea began to cover prescribed long-term oxygen therapy (LTOT) in patients with chronic respiratory insufficiency. This study examined the current status of LTOT after national health insurance coverage. Methods: Between November 1, 2006 and June 30, 2008, the medical records of patients who were prescribed LTOT by chest physicians were reviewed. The data was collected from 13 university hospitals. Results: 197 patients (131 male and 66 female) were prescribed LTOT. The mean age was 64.3${\pm}$13.0 years. The most common underlying disease was chronic obstructive pulmonary disease (n=103, 52.3%). Chest physicians prescribed LTOT using arterial blood gas analysis or a pulse oxymeter (74.6%), symptoms (14%), or a pulmonary function test (11.2%). The mean oxygen flow rate was 1.56${\pm}$0.68 L/min at rest, 2.08${\pm}$0.91 L/min during exercise or 1.51${\pm}$0.75 L/min during sleep. Most patients (98.3%) used oxygen concentrators. Only 19% of patients used ambulatory oxygen supplies. The oxygen saturation before and after LTOT was 83.18${\pm}$10.48% and 91.64${\pm}$7.1%, respectively. After LTOT, dyspnea improved in 81.2% of patients. The mean duration of LTOT was 16.85${\pm}$6.71 hours/day. The rental cost for the oxygen concentrator and related electricity charges were 48,414${\pm}$15,618 won/month and 40,352${\pm}$36,815 won/month, respectively. Approximately 75% of patients had a regular visit by the company. 5.8% of patients had personal pulse oxymetry. 54.9% of patients had their oxygen saturation checked on each visit hospital. 8% of patients were current smokers. The most common complaint with LTOT was the limitation of daily activity (53%). The most common complaint with oxygen concentrators was noise (41%). Conclusion: The patients showed good compliance with LTOT. However, only a few patients used an ambulatory oxygen device or had their oxygen saturation measured.

Cross-Sectional Relations of Arterial Stiffness and Inflammatory Markers in Korean Adults Aged 50 Years and Older (지역사회 거주 50세 이상 성인의 동맥경직도와 염증반응인자와의 관련성)

  • Ryu, So-Yeon;Shin, Min-Ho;Lee, Young-Hoon;Rhee, Jung-Ae;Choi, Jin-Su;Park, Kyeong-Soo;Nam, Hae-Sung;Jeong, Seul-Ki;Kweon, Sun-Seog
    • Journal of agricultural medicine and community health
    • /
    • v.36 no.2
    • /
    • pp.101-112
    • /
    • 2011
  • Objectives: The aim of this study is to determine arterial stiffness levels as measured by brachial-ankle pulse wave velocity (baPWV) and to identify the association between arterial stiffness and inflammatory markers, in healthy adults over 50 years old. Methods: The study population consisted of 4617 persons over the age of 50 years who participated in the baseline survey of the Dong-gu Study, which was conducted in 2007 and 2008. Arterial stiffness was measured using baPWV. A multiple regression analysis was performed to assess the relationship between conventional cardiovascular risk factors and inflammatory markers, including white blood cell (WBC) counts, high-sensitive C-reactive protein (hs-CRP), and gamma glutamyltransferase (GGT). Results: After adjustment for conventional cardiovascular risk factors including sex, age, smoking status, body mass index, systolic blood pressure, fasting glucose, hypertension or diabetic medication, total cholesterol, triglycerides, uric acid, and alanine aminotransferase, baPWV was significantly associated with WBC counts (${\beta}$=0.158, p<0.0001), hs-CRP (${\beta}$=0.244, p=0.026), and GGT (${\beta}$=0.003, p<0.0001). Conclusion: This study shows that arterial stiffness correlates with inflammatory markers. Arterial stiffness may be used as a composite risk factor to identify persons with higher risk for cardiovascular disease. Additionally, arterial stiffness may be a marker for future cardiovascular disease and a target for prevention.