• Title/Summary/Keyword: Pulse rate

Search Result 1,696, Processing Time 0.04 seconds

Distinction of Hot-Cold Using Fuzzy Inference (퍼지 추론에 의한 한열 판별)

  • Jang, Yun Ji;Kim, Young Eun;Kim, Chul;Song, Mi Young;Rhee, Eun Joo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.3
    • /
    • pp.141-149
    • /
    • 2015
  • Objectives Recently the fuzzy logic is widely used in the decision making, identification, pattern recognition, optimization in various fields. In this study, we propose the fuzzy logic as the objective method of distinguishing hot and cold, the basis of diagnosis in Korean medicine. Methods We developed fuzzy inference system to distinguish whether the subjects had hot or cold. The cold and hot questionnaire of Korean traditional university textbook, the pulse rate and the DITI value of face used in the system. These three kinds of information were defined as 'fuzzy sets,' and 54 fuzzy rules were established on the basis of clinical practitioners' knowledge. The fuzzy inference was performed by using the Mamdani's method. To evaluate the usefulness of the fuzzy inference system, 200 cases of data measured in the Woosuk university hospital of oriental medicine were used to compare the determining hot, normal, cold results obtained from the experts and from the proposed system. Results As a result, 100 cases of "cold", 54 cases of "normal", and 34 cases of "hot" were matched between the experts and the proposed system. This fuzzy system showed the conformity degree of 94%(${\kappa}=0.853$). Conclusions In this study, we could express the process of distinguishing hot-cold using the fuzzy logic for objectification and quantification of hot-cold identification. This is the first study that introduce a fuzzy logic for distinguish pattern identification. The degree of the heat characteristic of the patients inferred by this system could provide a more objective basis for diagnosing the hot-cold of patients.

Reaction of Cr Atoms with O2 at Low Pressures: Observation of New Chemiluminescence Bands from CrO2*

  • Son, Hyung-Su;Ku, Ja-Kang
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.226-232
    • /
    • 2004
  • Ground and low-lying electronic states of Cr atoms in the gas phase were generated from photolysis of $Cr(CO)_6$ vapor in He or Ar using an unfocussed weak UV laser pulse and their reactions with $O_2$ and $N_2O$ were studied. When 0.5-1.0 Torr of $Cr(CO)_6$ /$O_2$ /He or Ar mixtures were photolyzed using 295-300 nm laser pulses, broadband chemiluminescence peaked at ~420 and ~500 nm, respectively, was observed in addition to the atomic emissions from $z^7P^{\circ}$, $z^5P^{\circ}$, and $y^7P^{\circ}$ states of Cr atoms. When $N_2O$ was used instead of $O_2$, no chemiluminescence was observed. The chemiluminescence intensities as well as the LIF intensities for those three low-lying electronic states ($a^7S_3,\;a^5S_2\;and\;a^5D_J$) showed second-order dependence on the photolysis laser power. Also, the chemiluminescence intensities were first-order in $O_2$ pressure, but the presence of excess Ar showed a strong inhibition effect on them. Based on the experimental results, the chemiluminecent species in this work is attributed to $CrO_2^*$ generated from hot ground state Cr atoms with $O_2$. The apparent radiative lifetimes of the chemiluminescent species and collisional quenching rate constants by $O_2$ and Ar also were investigated.

First-Pass Observation using Tailored-RF Gradient Echo (TRFGE) MR Imaging in Cat Brain (자기공명 Tailored-RF 경사자계반향영상법을 이용한 고양이 뇌에서의 First-Pass관찰)

  • 문치웅;노용만
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.209-216
    • /
    • 1995
  • Recently, a new tailored RF gradient echo (TRFGE) sequence was reported. This technique not only enhances the magnetic susceptibility effect but also allows us to measure local changes in brain oxygenation. In this study, a phantom and cat brain experiments were performed on a 4.7 Tesla BIQSPEC (BRUKER) instrument with a 26 cm gradient system. We have demonstrated that the signal intensity (SI) of the TRFGE sequence varies according to the concentration of susceptibility contrast agent. Three capillary tubes with different concentrations of Gd-DTPA (0.01, 0.05, 0.1 mMOI/l) were placed at the middle of a cylindrical water phantom. Using both TRFGE and conventional gradient echo (CGE) sequences, phantom images of the slices which contain all three tubes were obtained. For the animal experiment, cats were anesthetized and ventilated using halotane (0.5%) and a $N_2O/ O_2$ mixture (2:1), and blood pressure and heart rate were monitored and kept normal. For the observation of tue first pass of Gd- DTPA, imaging was started at t = 0. At t = 8 ~ 12s, 0.2 mMol/Kg Gd-DTPA was manually injected in the femoral vein. The imaging parameters were TRITE = 25/10 msec, flip angle = $30^{\circ}$, FOV = 10cm, image matrix size = $128{\times}128$ with 64 phase encodings and the image data acquisition window was 10 msec. SI-time curves were then obtained from a series of 30 images which were collected at 2 sec intervals using both CGE and TRFGE pulse sequences before, during, and following the contrast injection.

  • PDF

Effect of Low Level Laser Irradiation on Osteoblast Cell Proliferation and Differentiation after Implant Placement

  • Oh, Min-Seok;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Lim, Sung-Chul;Son, Jun-Sik
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.42-47
    • /
    • 2009
  • Objective : The purpose of this study was to evaluate the effects of low level lasers on bone healing and new bone formation around titanium dental implants in canine models. 18 oxidized surface treated implants and a Dens-bio laser were used. Study design : Low level lasers were irradiated with a total of 8J for 4 minutes by pulse wave type and 1 minute by continuous type. For the experimental group, a low level laser was used to irradiate the first premolar implant's insertion area at the time of insertion, a low level laser was used to irradiate the second premolar implant's insertion area daily for one week after implant insertion, and a low level laser was used to irradiate the third molar implant's insertion area daily for 2 weeks postoperatively. At the conclusion of the study, sacrificed tissue sections were made from investing tissue and observed under an optical microscope. Results : The rate of new bone formation around the implant showed no significant difference between the control group and the experimental group. New bone formation rates of the control and experimental group 2 weeks following implant placement were higher than that of immediately after implant placement and 1 week after implant placement. Conclusions : Based on these results, a low-level laser showed no statistically significant increase in bone formation following implant placement.

  • PDF

Effects of the APACHEIII Score, Hypermetabolic Score on the Nutrition Status and Clinical Outcome of the Patients Administered with Total Parenteral Nutrition and Enteral Nutrition (경정영양과 중심정맥영양을 공급받는 환자에서 질병의 상태(APACHEIII Score), 과대사 정도가 영양상태 및 임상적 결과에 미치는 영향)

  • Rha Mi yong;Kim Eun mi;Cho Young Y.;Seo Jeong Meen;Choi Hay mie
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.1
    • /
    • pp.124-132
    • /
    • 2006
  • The aim of this study is to evaluate the clinical outcome. Between January 1,2002 to September 30, 2002, we prospectively and retrospectively recruited III hospitalized patients who received Enteral Nutrition (EN group n = 52) and Total Parenteral Nutrition (TPNgroup n = 59) for more than seven days. The factors of clinical outcomes are costs, incidences of infection, lengths of hospital stay, and changes in weight. The characteristics of patients were investigated, which included nutritional status, disease severity CAP ACHE III score) and hypermetabolic severity Chypermetabolic score). Hypermeta-bolic scores were determined by high fever (> $38^{\circ}C$), rapid breathing (> 30 breaths/min) , rapid pulse rate (> 100 beats/min), leukocytosis (WBC > 12000 $mm^{3}$), leukocytopenia (WBC > 3000 $mm^{3}$), status of infection, inflammatory bowel disease, surgery and trauma. There was a positive correlation between hypermetabolic score and length of hospital stay (ICU), medical cost, weight loss, antibiotics adjusted by age while APACHEIII score did not show correlation to clinical outcome. Medical cost was higher by $18.2\%$ in the TPN group than the EN group. In conclusion, there was a strong negative correlation between the clinical outcome (cost, incidence of infection, hospital stay) and hypermetabolic score. Higher metabolic stress caused more malnutrition and complications. For nutritional management of patients with malnutrition, multiple factors, including nutritional assessment, and evaluation of hypermetabolic severity are needed to provide nutritional support for critically ill patients.

Experimental Study on Regenerator Under Cryogenic Temperature and Pulsating Pressure Conditions (극저온 맥동 압력 조건에서의 재생기에 관한 실험적 연구)

  • Nam, Gwan-U;Jeong, Sang-Gwon;Jeong, Eun-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1095-1101
    • /
    • 2002
  • An experimental apparatus was prepared to investigate thermal and hydrodynamic characteristics of regenerator at cryogenic temperature under pulsating pressure condition. The regenerator was pressurized and depressurized by a compressor with various operating frequencies. Cold end of the regenerator was maintained around 100 K by means of a liquid nitrogen heat exchanger. Instantaneous gas temperature and mass flow rate were measured at both ends of the regenerator during the whole pressure cycle. Pulsating pressure drop across the regenerator was also measured to see if it could be predicted by a friction factor at steady flow condition. The operating frequency of pressure cycle was varied between 3 and 60 Hz, which are typical operating frequencies of Gifford-McMahon, pulse tube, and Stilting cryocoolers. First, the measured friction factor for typical wire screen mesh regenerator was nearly same as steady flow friction factor for maximum oscillating Reynolds number up to 100 at less than 9 Hz. For 60 Hz operations, however, the discrepancy between oscillating flow friction factor and steady flow one was noticeable if Reynolds number was higher than 50. Second, the ineffectiveness of regenerator was directly calculated from experimental data when the cold-end was maintained around 100 K and the warm-end around 293 K, which simulates an actual operating condition of cryogenic regenerator. Influence of the operating frequency on ineffectiveness was discussed at low frequency range.

Numerical Investigation on Soot Primary Particle Size Using Time Resolved Laser Induced Incandescence (TIRE-LII) (시분해 레이저 유도 백열법을 이용한 매연 입자 크기에 관한 수치적 연구)

  • Lee, Jong-Ho;Kim, Jeong-Yong;Jeong, Dong-Soo;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1022-1031
    • /
    • 2005
  • Temporal behavior of the laser induced incandescence (LII) signal is often used for soot particle sizing, which is possible because the cooling behavior of a laser heated particle is dependent on the particle size. In present study, LII signals of soot particles are modeled using two non-linear coupled differential equations deduced from the energy- and mass-balance of the process. The objective of this study is to obtain an appropriate calibration curve for determining primary particle size by comparing the gated signal ratio and double-exponential curve fitting methods. Not only the effects of laser fluence and gas temperature on the cooling behavior but also heat transfer mechanisms of heated soot particle have been investigated. The second-order exponential curve fitting showed better agreements with the LII signals than the gated signal ratio method which was based on the lust-order exponential curve fit. And the temporal decay rate of the LII signal and primary particle size showed nearly linear relationship, which was little dependent on the laser fluence. And it also could be reconfirmed that vaporization was dominant process of heat loss during first loons after laser pulse, then heat conduction played most important role while thermal radiation had little influence all the time.

Isolation and Characterization of a Mutant Defective in Light-activated Heterotrophic Groth from Synechocystis sp. PCC 6803 (Synechocystis sp. PCC 6803으로부터 광활성 종속영양 생장결핍 돌연변이체의 분리 및 특성)

  • Park, Mi-Seon;Lee, Young-Sook;Kim, Young-Chang
    • Korean Journal of Microbiology
    • /
    • v.32 no.3
    • /
    • pp.202-207
    • /
    • 1994
  • A mutant strain PRM1 defective in light-activated heterotrophic growth was isolated from Synechocystis sp. PCC 6803. PRM1 could be grown at growth rate equivalent to Synechocystis 6803 under mixotrophic growth conditions. However, PRM1 could not be grown under light-activated heterotrophic conditions, in which a daily pulse of light for 5 min was given. These results suggest that PRM1 is not defective in heterotrophic metabolism, but in the transduction pathway of light signal essential to the growth. Plasmid patterns, absorption spectra of whole cells, and the exterior and interior structures of PRM1 were similar to those of Synechocystis 6803, except that PRM1 could not produce amorphous slime holding cells together.

  • PDF

CROSS-INTERFEROMETRY FOR DEM CONSTRUNTION WITH ERS-ENVISAT PAIR

  • Hong Sang-Hoon;Won Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.542-545
    • /
    • 2005
  • Spaceborne radar interferometry has been widely used to estimate the topography and deformation of the Earth. It is difficult to obtain coherent interferometric SAR pairs especially over coastal areas mainly because of variation of surface conditions. We carried out the experiment using a cross-interferometric pair with a perpendicular baseline of about 1.4 km, a 30 minutes temporal separation and the height sensitivity of about 6 meters. The temporal decorrelation can be reduced by the cross interferometric technique with a 30 minutes temporal separation. Accurate coregistration was performed through resampling of ENVISAT ASAR data to equivalent pixel spacing to the ERS SAR data, because of the differences of the pulse repetition frequency and range sampling rate between the two sensors. Then we estimated range and azimuth offset to a sub-pixel accuracy using image intensity cross correlation. A larger window chip size than a general case was used because it was difficult to distinguish typical features. As range bin increased, the difference of Doppler centroid also increased. It resulted in lower coherence in far range than in near range. Coherences over wetland in near and far range were about 0.8 and 0.5, respectively. The coherence was improved by applying azimuth and range common band filtering, but coherence gap still existed. ERS-ENVISAT cross-interferogram usually lost information in urban area. However, high coherence over a city in this pair was shown, because of less man-made structures than other major cities. Accuracy of the DEM constructed by the ERS-ENVISAT 30-minute pair in a coastal area is to be evaluated.

  • PDF

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF