• Title/Summary/Keyword: Pulse rate

Search Result 1,677, Processing Time 0.037 seconds

Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device (영구자석과 홀소자로 구비된 집게형 맥진기를 이용한 맥진파형 측정과 분석)

  • Son, Il-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.3
    • /
    • pp.104-107
    • /
    • 2011
  • We measured signals at the "Guan" region of a radially arterial pulse using the prototype of a clamping pulsimeter equipped with a Hall effect device, which is passed signals through the voltage detecting hard ware system. The important four different measuring times of the period, systolic, reflective, and notch peaks for a temporally pulse signal are obtained and compared each other from the analysis for an arbitrary pulse wave of one position of small size permanent magnet. It is possible to measure the reproducible pulse rate and blood pressure by using the cuffless clip type pulsimeter without an unpleasant oppressive feeling due to the use of pressurization.

Remote Monitoring of Patients and Emergency Notification System for U-Healthcare

  • Lee, Jun;Jang, Hyun-Se;Yang, Tae-Kyu;Seo, Yong-Ho
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • This study proposes a remote monitoring of patients and emergency notification system with a camera and pulse wave sensor for U-Healthcare. The proposed system is a server client model based U-Healthcare system which consists of wireless clients that have micro-controller, embedded-board for patient status monitoring and a remote management server. The remote management server observes the change of pulse wave data individually in real-time sent from the clients that is to be remote-monitored based on the pulse wave data stored by users and divides them into caution section and emergency section. When the pulse wave data of a user enters an emergency situation, the administrator can make a decision based on the real-time image information and pulse rate variability. When the status of the monitored patient enters the emergency section, the proposed U-healthcare system notifies the administrator and relevant institutions. An experiment was conducted to demonstrate the pulse wave recognition of the proposed system.

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Improvement and Limitations in the Sasang Constitution Diagnosis by the Instrument-based Pulse Diagnosis (맥진을 이용한 사상체질 판별 방법의 개선 및 의의)

  • Kim, Jae-Uk;Kim, Sung-Hun;Lee, Yu-Jung;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Jong-Yoel
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2009
  • Recently, there have been emerging research activities in classifying the Sasang constitution objectively by machine-based methods. The concordance rate of the classification by the pulse wave features was, however, only around 50% up to now. In this paper, we introduce a novel classification algorithm that can promote the accuracy substantially at the expense of the non-classifiable subgroup as a byproduct. For instance, with the pulse wave features alone, we show that female/male subject group in their 20s can be classified into the Sasang constitution group with the concordance rate of 68.4%/65.5% for a subgroup of 57/29(31%/15%) subjects out of 184/195, by leaving the other subjects as the non-classifiable group. Next, we show that the pulse diagnosis has been used only as a supportive tool in determining one's constitution, and consequently the accuracy of the concordance ratio by the pulse wave features alone cannot exceed a finite value, which we estimate to be about 60%.

  • PDF

Wavelength and Repetition-Rate Tunable Optical Pulse Generation for Ultrafast OTDM/WDM (초고속 OTDM/WDM을 위한 파장 및 반복율 가변 광 펄스 발생)

  • Choi, Kyoung-Sun;Han, Chong-Min;Seo, Dong-Sun;Jhon, Young-Min;Lee, Seok
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.201-210
    • /
    • 2001
  • Wavelength and repetition-rate tunable optical pulse-trains for ultrafast optical time- and wavelength division multiplexing are generated from a semiconductor fiber ring laser by optical injection mode-locking. The pulse trains show the pulse with of ${\sim}10$ ps and the wavelength tuning of wider than 30 nm at various repetition-rates of 10 GHz, 20 GHz, 30 GHz and 40 GHz, respectively.

  • PDF

Transition-limited pulse-amplitude modulation technique for high-speed wireline communication systems

  • Eunji Song;Seonghyun Park;Jaeduk Han
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.974-981
    • /
    • 2023
  • This paper presents a transition-limited pulse-amplitude modulation (TLPAM) signaling method to enable a high data rate and robust wireline communications. TLPAM signaling addresses the impact of high intersymbol interference (ISI) ratios in conventional M-ary PAM signaling methods by limiting the maximum voltage transition level between adjacent symbols. The implementation of a TLPAM signaling encoder is realized by setting back the most significant bits (MSBs) in the queue. The correlation between TLPAM's maximum transition level, effective data rate, and eye width/height is analyzed with various channel loss parameters, followed by characterization and measurement results with a realistic channel setup. The analysis and experimental results reveal the effectiveness of the proposed TLPAM signaling scheme for achieving a high data rate with minimal interference.

Effects of bee venom acupuncture on heart rate variability, pulse wave, and cerebral blood flow for types of Sasang Constitution (봉약침 자극이 사상체질별 건강인의 심박변이도, 맥파, 뇌혈류에 미치는 영향)

  • Lee, Sang-Min;Kim, Koo;Oh, Seung-Yun;Kwon, Young-Mi;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • 1. Objectives To evaluate effects of bee venom acupuncture on cardiovascular system and differences according to each constitution. 2. Methods Heart rate variability, pulse wave and the velocity of cerebral blood flow were measured before bee venom acupuncture(BVA), right after and after 30 minuets, had been applied to 20 subjects. 3. Results 1. BVA did not have effects on measurement variables of heart rate variability. 2. BVA had effects on pulse wave, showing total time, radial augmentation index up and height of percussion wave, time to percussion wave, sum of pulse pressure down. 3. BVA did not have effects on the cerebral blood flow velocity when considering not Sasang Constitution. 4. Considering Sasang Constitution, BVA demonstrates different responses in time to preincisura wave, mean blood flow velocity, peak systolic velocity and end diastolic velocity. 4.Conclusion From those results, the following conclusions are obtained. Cause BVA alters pulse wave and makes differences in the cerebral blood flow velocity according to Sasang Constitution. Various methods of BVA treatment are needed considering Sasang Constitution.

2-dimensional Measurement of Arterial Pulse by Imaging Devices (촬상소자를 이용한 맥동의 2차원 계측)

  • Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

A Study on Closed-Loop Control of a Stepping Motor for Resonance Elimination (공진배제를 위한 스템핑 모터의 폐회로제어에 관한 연구)

  • 노상현;김교형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.90-97
    • /
    • 1991
  • A stepping motor can be driven with open-loop or closed-loop control. The major disadvantage of open-loop control is that it is subjected to resonance and instability in certain speed range, and that there is no way to check stalling or error in position. In this paper, a closed-loop control system consisting of a microcomputer, a hybrid stepping motor, a drive, a lead screw, and an encoder which is used as a position sensor is developed. A control program is programmed in assembly language for real time control and the versatile interface adapter(VIA) is used as the interface with the microcomputer. The experimental results of the stepping motor were eliminated on all kinds of inertia load, and maximum start stop pulse rate and maximum slewing pulse rate were also increased about twice respectively.