Implementation of DS-UWB Impulse Generator with Suppression of Frequency Band for WLAN (WLAN 주파수 대역이 억제된 DS-UWB 임펄스 생성기 구현)

  • Park, Chong-Dae;Kim, Bum-Joo;Kim, Dong-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • In this paper, Gaussian impulse generator for DS-UWB was proposed and fabricated so that the frequency band allocated to WLAN, around 5 GHz, was suppressed in accordance with the regulation of radiation spectrum limitation defined by FCC. In order to transform an unipolar rectangular signal to a Gaussian impulse, the proposed impulse generator consists of two stage impulse generation parts; the first stage using dual SRD and the second stage using gain switching of semiconductor laser diode. The result shows a gaussian impulse as narrow as 180 psec in width. In addition, high order derivative Gaussian filter with a structure of 4 stage ring resonators was designed and fabricated so that DS-UWB impulse generator could reduce the frequency spectrum of WLAN by 25 dB compared to the spectral power of th adjacent UWB band.

  • PDF

TID and SEGR Testing on MOSFET of DC/DC Power Buck Converter (DC/DC 강압컨버터용 MOSFET의 TID 및 SEGR 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.981-987
    • /
    • 2014
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a MOSFET (metal-oxide semiconductor field effect transistor), a PWM-IC (pulse width modulation-integrated circuit) controller, inductor, capacitor, etc. It is shown that the variation of threshold voltage and the breakdown voltage in the electrical characteristics of MOSFET occurs by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 5 heavy ions make the gate of MOSFET broken in SEGR (Single Event Gate Rupture) testing. TID testing on MOSFET is accomplished up to the total dose of 40 krad, and the cross section($cm^2$) versus LET(MeV/mg/$cm^2$) in the MOSFET operation is studied at SEGR testing after implementation of the controller board.

Effect of Sterilization by Intense Pulsed Light on Radiation-resistant Bacterium, Micrococcus roseus (방사선 저항세균 Micrococcus roseus의 광펄스 살균 효과)

  • Kim, Bora;Kim, Ae-Jin;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.248-251
    • /
    • 2013
  • The purpose of this study was to investigate the inactivation effect of intense pulsed light (IPL) on Micrococcus roseus, an irradiation-resistant bacterium isolated from laver, and the commercial feasibility of this sterilization method on dried laver. The inactivation of M. roseus in cultivated plates increased with increasing light intensity and treatment time. Approximately 6.6 log CFU/mL reduction of the cell viability was achieved with IPL treatment for 3 min at 1,000 V of light intensity, tailing was not shown. In addition, the inactivation rate of M. roseus increased with increasing pulse number at same light intensity and treatment time. The killing efficiency for M. roseus increased with by decreasing the distance between the light source and the sample surface.

Prediction of coal and gas outburst risk at driving working face based on Bayes discriminant analysis model

  • Chen, Liang;Yu, Liang;Ou, Jianchun;Zhou, Yinbo;Fu, Jiangwei;Wang, Fei
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.73-82
    • /
    • 2020
  • With the coal mining depth increasing, both stress and gas pressure rapidly enhance, causing coal and gas outburst risk to become more complex and severe. The conventional method for prediction of coal and gas outburst adopts one prediction index and corresponding critical value to forecast and cannot reflect all the factors impacting coal and gas outburst, thus it is characteristic of false and missing forecasts and poor accuracy. For the reason, based on analyses of both the prediction indicators and the factors impacting coal and gas outburst at the test site, this work carefully selected 6 prediction indicators such as the index of gas desorption from drill cuttings Δh2, the amount of drill cuttings S, gas content W, the gas initial diffusion velocity index ΔP, the intensity of electromagnetic radiation E and its number of pulse N, constructed the Bayes discriminant analysis (BDA) index system, studied the BDA-based multi-index comprehensive model for forecast of coal and gas outburst risk, and used the established discriminant model to conduct coal and gas outburst prediction. Results showed that the BDA - based multi-index comprehensive model for prediction of coal and gas outburst has an 100% of prediction accuracy, without wrong and omitted predictions, can also accurately forecast the outburst risk even for the low indicators outburst. The prediction method set up by this study has a broad application prospect in the prediction of coal and gas outburst risk.

A Study in the Crimes of the Medical Practice without License - Case of Oriental Medicine's use of Ultrasounds - (무면허의료행위에 대한 형사법적 쟁점 - 한의사의 초음파기기 사용을 중심으로 -)

  • Jang, Jun Hyuk
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.35-57
    • /
    • 2014
  • Recently, there has been fierce argument between oriental and western doctors in the medical field. The use of medical devices has particularly come to the fore lately. Appropriate medical devices are required to diagnose and treat patients' conditions or illnesses accurately. At issue recently in medical device sector are diagnostic instruments using radiation, magnetic resonance imaging, ultrasound, IPL(Intense Pulse Light), and instruments used for tonometry. Relating to this issue, Association of Korean Oriental Medicine and The Association of Korean Medicine are sharply opposed. It is predicted that more accusations of this kind will be seen in the future. As oriental medicine contends, ultrasonic imaging itself seems to cause no harm to humans and its use may have an advantage for national health. The use of western diagnostic equipment can expand the diagnostic range of oriental doctors. However, unless new legislation is made, it is against the law for oriental doctors to use this equipment. Both law and medical science require grounds and predictability on the correctness of a decision and all of its consequences. Additionally, oriental medicine's use of ultrasounds and other medical devices should be established by standards and grounds which make same the diagnosis with repetition. Therefore, the scope of oriental medicine can be expanded following a revision of the Oriental Medicine Promotion Act and it is estimated that the state of national health will be greatly improved by the mutual respect of both sides of the health profession.

  • PDF

Thermopower Wave in Core-Shell Structures of Carbon Nanotube Chemical Fuels (나노튜브/화학연료의 동축 구조에서 생성되는 열동력 파도를 이용한 전기 에너지 생성)

  • Choi, Wonjoon;Strano, Michael S.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.615-620
    • /
    • 2013
  • There is considerable interest in developing energy sources capable of larger power densities. In our previous works, we proved that by coupling an exothermic chemical reaction with 1D nanostructures, a self-propagating reactive wave can be driven along its length with a concomitant electrical pulse of high specific power, which we identified as a thermopower wave. Herein, we discuss details about many different aspects of a thermopower wave. Different alignment degree in vertically aligned CNT films is evaluated in the reactive wave speed and correlated with its thermal reaction that affects the change in the magnitude of energy generation. The effects of the temperature-dependent properties of chemical fuels and CNTs are evaluated. Furthermore, we explore the convection and radiation portions in this thermal wave as well as the synchronization between the thermal reaction transfer and the oscillation of the electrical signal.

In Situ X-ray Photoemission Spectroscopy Study of Atomic Layer Deposition of $TiO_2$ on Silicon Substrate

  • Lee, Seung-Youb;Jeon, Cheol-ho;Kim, Yoo-Seok;Kim, Seok-Hwan;An, Ki-Seok;Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.222-222
    • /
    • 2011
  • Titanium dioxide (TiO2) has a number of applications in optics and electronics due to its superior properties, such as physical and chemical stability, high refractive index, good transmission in vis and NIR regions, and high dielectric constant. Atomic layer deposition (ALD), also called atomic layer epitaxy, can be regarded as a special modification of the chemical vapor deposition method. ALD is a pulsed method in which the reactant vapors are alternately supplied onto the substrate. During each pulse, the precursors chemisorb or react with the surface groups. When the process conditions are suitably chosen, the film growth proceeds by alternate saturative surface reactions and is thus self-limiting. This makes it possible to cover even complex shaped objects with a uniform film. It is also possible to control the film thickness accurately simply by controlling the number of pulsing cycles repeated. We have investigated the ALD of TiO2 at 100$^{\circ}C$ using precursors titanium tetra-isopropoxide (TTIP) and H2O on -O, -OH terminated Si surface by in situ X-ray photoemission spectroscopy. ALD reactions with TTIP were performed on the H2O-dosed Si substrate at 100$^{\circ}C$, where one cycle was completed. The number of ALD cycles was increased by repeated deposition of H2O and TTIP at 100$^{\circ}C$. After precursor exposure, the samples were transferred under vacuum from the reaction chamber to the UHV chamber at room temperature for in situ XPS analysis. The XPS instrument included a hemispherical analyzer (ALPHA 110) and a monochromatic X-ray source generated by exciting Al K${\alpha}$ radiation (h${\nu}$=1486.6 eV).

  • PDF

The study on oriental and western medicine of esophagitis (식도염(食道炎)에 대(對)한 동서의학적(東西醫學的) 고찰(考察))

  • Choi, Chang-woo;Son, Chang-gyu;Cho, Chong-kwan
    • Journal of Haehwa Medicine
    • /
    • v.10 no.2
    • /
    • pp.91-96
    • /
    • 2002
  • We arrived at the following conclusions after we have studied esophagitis through the literatures of oriental and western medicine. 1. The western medical causes of acute esophagitis are corrosiveness chemical material, esophageal or gastric disease, trauma, blister stomatitis, filamentous fungus infection and uremia of chronic patient etc, and the oriental medical causes are qi and blood stagnation, blood stasis and stagnation, stagnant phlegm by coldness, heating, dyspepsia and food poisoning etc. 2. The western medical causes of chronic esophagitis are malfunction of lower esophageal sphincter, esophageal tom chink and hernia, increase of gastric pressure by overeating, fatness, pregnancy and ascites etc, and the oriental medical causes are asthenic cardiac qi, hepatic qi attacking stomach by seven kinds of depression, cold-damp stagnation and insufficiency of gastric qi by overeating, excessive drinking and sexual indulgence etc. 3. The main symptoms of acute esophagitis are severe chest pain, instantly vomiting, swallowing pain etc, and chronic esophagitis are occasionally light chest pain, heart bum, anorexia, dysphagia, dizziness, general body weakness etc. These symptoms are come under thoracic obstruction, acid regurgitation, vomiting and chest pain of oriental medicine. 4. The western medical diagnoses of acute and chronic esophagitis have used radiation test, esophageal endoscopy, esophageal pressure test and biopsy etc, and the oriental medical diagnoses have used syndrome differentiation by four examination of inspection, listening and smelling examination, inquiring, pulse-taking and palpitation. 5. The western medical treatments of acute esophagitis have regarded preservation stability of esophagus as a principle, and the oriental medical treatments mainly have used expelling pathogen of expelling cold and regulating qi, cooling and removing stasis, promoting blood circulation to remove blood stasis, eliminating phlegm and regulating qi. 6. The western medical treatments of chronic esophagitis have regarded decrease flowing backward of gastric juice as a purpose, and the oriental medical treatments mainly have used strengthening body resistance of replenishing and strengthening cardioqi, dispersing stagnated hepatoqi, expelling cold and dehygrosis, invigorating stomach and nourishing qi.

  • PDF

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.291-309
    • /
    • 1973
  • Exposure rates due to leakage gamma-rays from operating reactors TRIGA Mark II and III were measured in a horizontal plane by means of scintillation spectrometry using a 3"$\times$3" cylindrical Nal(T1) detector associated with a 400 channel pulse height analyzer under varied conditions of reactor operation. In determining exposure rate due to the leakage gamma-rays at each point of measurement, Moriuchi's spectrum-exposure rate conversion theory was applied instead of using conventional responce matrix method which necessitates very complicated procedures to convert a spectrum into exposure rate. The results show that a basic pattern of "typical" spectrum of the reactor leakage gamma-rays is neither affected by thermal output of the reactor, nor influenced by overall attenuation in radiation intensity. It was indicated that he attenuation of the leakage gamma-rays in air in terms of exposure rate as a whole follows an exponential law, and the total exposure rate due to the leakage gamma-rays at a certain point is nearly proportional to thermal output of the reactor. The complexity in spectrum measured for a movable core reactor, TRIGA Mark III, was analyzed through spectrum resolution, and proper judgement of the leakage gamma-rays in a complex spectrum was discussed.ctrum was discussed.

  • PDF

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.