• 제목/요약/키워드: Pulse magnetic field

검색결과 151건 처리시간 0.026초

Noninvasive Brain Stimulation Using a Modulated Microwave Signal

  • Seo, Taeyoon;Oh, Seongwoog;Jung, Dahee;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • 제18권1호
    • /
    • pp.70-72
    • /
    • 2018
  • We propose a microwave signal generation system for brain stimulation. The existing brain stimulation system uses a signal of several tens of kHz, and the magnetic field distribution is wide. Microwave is used to locally limit the distribution of the electromagnetic field and to change the action potential of the cell with less power. The switch modulates the microwave signal to obtain a pulse envelope. The action potential of the cell can be controlled to the excitation/inhibition state by adjusting the repetition frequency. These results are confirmed by measuring the cell potential of the mouse brain.

복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교 (Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2016
  • 본 연구의 목적은 복부 자기공명영상에서 주로 적용되고 있는 4 종류의 펄스시퀀스를 중심으로 1.5 T 와 3.0 T 기기의 자기장의 차이로 나타나는 자기장의 속성 및 인공물 발생 차이를 비교하기 위해 분석을 하였다. PACS network로 전송된 총 500 명의 데이터를 정량적으로 SNR 값을 분석하였고, MSA, CSA, DA을 3 단계로 구분하여 정성적 평가를 하였다. 정량적 평가에서 SNR 값은 1.5 T 값 보다 의미 있는 결과로 높은 값을 얻었지만(p<0.05), 영상의 인공물이 발생하여 영상의 질을 저하시키는 요인도 있었다(p<0.05). 1.5 T는 3.0 T 보다 인공물 발생이 적어 3.0 T 만큼에 영상의 질을 보상 할 수가 있었다(0.05). 결론적으로, 이러한 결과를 토대로 자기장의 차이에 따라 발생되는 자기장의 속성 및 인공물 발생 차이를 파악 할 수 있었으며 이에 따른 대처방안을 제공할 수 있었다. 향후 임상현장에서 두 기기를 이용하여 복부 자기공명영상을 검사 할 때 환자를 직접 검사하는 MRI 사용자에게 가이드라인이 될 것이다.

자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구 (Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device)

  • 장덕형;김담비;최슬기;이상석
    • 한국자기학회지
    • /
    • 제22권4호
    • /
    • pp.130-135
    • /
    • 2012
  • 요골동맥의 중심인 "관" 위치에 영구자석을 붙인 후 바로 위쪽에 자성측정용 반도체 홀소자를 장착하여 전압 신호를 검출하는 하드웨어 시스템이 적용된 집게형 맥진기 시제품을 개발하였다. 집게형 맥진기와 용적맥파계를 동시 분석하는 시스템으로 20대 나이 임상참가자 40명 각각에 대한 맥진파형과 용적맥파형 두 피크값을 비교 측정한 결과 혈류속도가 평균 0.8 m/s로 기존 값과 거의 비슷하였다. 이로써 요골동맥파형-용적맥파형을 환자감시장치에서 제시하는 주요 임상의 주요값으로 적용할 수 있음을 제시하였다.

은 피복 Bi-2223 고온초전도 선재의 안정성 (Stability of Ag Sheathed Bi-2223 HTS Tape)

  • 장현만;오상수;하홍수;하동우;정종만;류강식;김상현
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.369-372
    • /
    • 1999
  • Using Ag sheathed multi filamentary Bi-2223 tape, stability against heat pulse has been investigated. The measured normal zone propagation(NZP) velocity of the tape was found to be faster due to increase of operating current and magnetic field, and agree well with calculated data from one dimensional heat balance equation. Minimum quench energy(MQE) was found to be larger than 17 J at 30 K zero magnetic filed at operating current of 96.5 with respect to I$_c$.

  • PDF

디지털 제어 방식의 고속 PWM 전류 증폭기의 구현에 관한 연구 (Study on the Implementation of the Digital Controller of High-Speed PWM Current Amplifier)

  • 고덕화;백광렬
    • 제어로봇시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.97-103
    • /
    • 2002
  • This paper deals with a PWM(Pulse Width Modulation) current amplifier using digital controller in order to generate a gradient magnetic field far the MRI(Magnetic Resonance Image) system. Because of tolerance of discrete devices, it is difficult to set accurate values of the control parameters and to make an analog-controlling circuit. However, using digital controller, it is possible to set exact control parameters and to adopt a modern control techniques. It is shown that the digital controller will highly enhance the output current response and it will improve the quality of the MRI.

PWM 방식 고속 전자석에 관한 연구 (A study on the PWM type High Speed Electromagnet)

  • 송창섭;양해정;송성배
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.127-135
    • /
    • 1994
  • This paper is concerned about a high speed electromagnet of Pressure control solenoid valve. Solenoid valve is controlled by means of Pulse width modulation. The magnetostatic field problem on a solenoid is numerically solved by the 2-D axisymmetric finite element method. And permeance method is adopted for analysing the static and dynamic property of solenoid part theoretically. In addition, in this study, experiments on solenoid part were performed in order to measure the magnetic force and plunger displacement. The numerical results coincided with the experimental results. As a result, the magnetic force has the linear relation with displacement of plunger and the primary factors on the performance of PWM type high speed electromagnet are coil resistance, plunger mass, and the length of air gap between plunger and core.

  • PDF

자수기 특성을 고려한 LPM의 설계에 관한 기초연구 (The Basic Study on Design of Linear Pulse Motor for Embroidery Machine Characteristics)

  • 박창순;권태근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.765-767
    • /
    • 2001
  • Linear pulse Motors(LPM) are widely used in fields where smooth linear motion is required, and their position accuracy is higher than other motors. Hybrid linear pulse motors(HLPM) are regarded as an excellent solution to positioning problems that require high accuracy, rapid acceleration and high-speed. The LPM has low mechanical complexity, high reliability, precise open-loop operation and low inertia etc. in many application areas such as factory automation speed positioning, computer peripherals and numerically controlled machine tools. This motor drive system is especially suitable for machine tools the high position accuracy and repeatability. This paper describes about that need of the embroider machine, we want to design position-scanning device for the embroidery machine. At first, to be analysed characteristics of the machine and next designed the LPM. we used the field analysis program, The finite element method(FEM) program tool is employed for calculation the force. The reluctance models will be used the magnetic permeance of air gap by static- conditions. The forces between forcer and platen have been calculated using the virtual work method.

  • PDF

Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

  • Lee, Sang-Suk;Choi, Jong-Gu;Son, Il-Ho;Kim, Keun-Ho;Nam, Dong-Hyun;Hong, You-Sik;Lee, Woo-Beom;Hwang, Do-Guwn;Rhee, Jang-Roh
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.449-452
    • /
    • 2011
  • A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus.

자수기에 맞는 LPM의 설계와 구동 특성에 관한 연구 (The Study on Design and Dynamic Operation Characteristics of Linear Pulse I for Embroidery Machine)

  • 박창순;권태근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.91-93
    • /
    • 2001
  • Linear pulse Motors(LPM) are widely used in fields where smooth linear motion is required, and their position accuracy is higher than other motors. Hybrid linear pulse motors(HLPM) are regarded as an excellent solution to positioning problems that require high accuracy, rapid acceleration and high-speed. The LPM has low mechanical complexity, high reliability, precise open-loop operation and low inertia etc. In many application areas such as factory automation speed positioning, computer peripherals and numerically controlled machine tools, LPM can be used. This motor drive system is especially suitable for machine tools the high position accuracy and repeatability. This paper describes about that need of the embroider machine, we want to design position-scanning device for the embroidery machine. At first, to be analysed characteristics of the machine and next designed the LPM, we used the field analysis program. The finite element method(FEM) program tool is employed for calculation the force. The reluctance models will be used the magnetic permeance of air gap by static-conditions. The forces between forcer and platen have been calculated using the virtual work method. And we used the simulink to know the dynamic characteristics of LPM.

  • PDF

Statistics on Radiation Field Waveforms Associated with Multiple Intracloud Lightning Discharges

  • Lee, Bok-Hee;Lee, Dong-Moon;Ahn, Chang-Hwan;Kim, Young-Bong
    • Journal of KIEE
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 2001
  • This paper presents the detailed statistics on radiation field signatures associated with multiple-intracloud lightning discharges. A transient signal recording system was used to measure the electric and magnetic fields produced by lightning flashes. The measurements were made in th summers of 1995 through 1999, and the location of the observation station was in Inchon on the coast of the Yellow Sea in Korea(37$^{\circ}$25'N, 126$^{\circ}$ 39'E). Most of lightning flashes typically contains between two and five strokes. The individual intracloud stork radiation fields were the bipolar pulse. On the average, the ratio of the peak of the second stroke to the first stroke peak was 75.1$\pm$40.1% for the negative, and a fraction of the subsequent stroke peaks were higher than the first stroke peak. The greater the number of the subsequent stroke order, less time separations between strokes were produced. The mean of the depth of the dip was 81.2$\pm$27.9% for the positive polarity and 75.9$\pm$24.4% for the negative. The depth of the dip increased for the positive bipolar pulses and decreased for the negative as the number of the stroke order increased.

  • PDF