• 제목/요약/키워드: Pulse jet type

검색결과 29건 처리시간 0.019초

사각형 여과 집진기 충격기류 탈진시스템의 기초 연구 (The Fundamental Study on Pulse Jet Cleaning of Rectangular Bag-Filter System)

  • 박승욱;김태형;양준호;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.149-160
    • /
    • 2008
  • Bag-filter system has been widely used in industrial field to remove the particulate matters from the exhaust gas. The cylindrical type of bag-filter has been generally used. But it has many shortcomings. The reattachment of separated particles on the surface of bags could result in high pressure drop of bag-filter system and subsequent decrease of air flow rate since the cylindrical type bag-filter system should have the upward flow pattern. In addition, the supply of very high pressure pulse air jet to remove particulate matters on the surface of filter could result in a frequent rupture of bags. To overcome these shortcomings of the cylindrical type, the rectangular type was developed in the developed countries and imported to Korea. But, there was not many design data available to understand the mechanisms. Thus, the fundamental experiments were conducted in this study to get some ideas about the pulse jet cleaning of rectangular type bag filter system. The experimental factors are as follows; pulse distance, pulse duration, pulse interval, pulse pressure and pulse nozzle type. Experiments followed the factorial design method. With the shorter pulse distance, the distribution of pressure drops was relatively not uniform while the particulate removal efficiency was higher. With the longer duration of pulsing and the more number of pulse nozzle, the removal efficiency was higher and the pressure drop distribution was more uniform.

간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측 (Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance)

  • 손정삼;정용현;서정민
    • 한국환경과학회지
    • /
    • 제32권11호
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.

카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구 (Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System)

  • 박승욱;하현철;김성준
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

충격기류식 여과집진장치에서 압력손실에 영향을 주는 인자의 효율예측 (Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter)

  • 서정민;류재용;임우택;정문섭;박정호;신춘환
    • 한국환경과학회지
    • /
    • 제19권4호
    • /
    • pp.437-446
    • /
    • 2010
  • The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 m2 filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

연속탈진형 충격기류식 여과집진장치의 여과포 유효탈진거리 예측 (A Study on Prediction of On-line Type Pulse Air Jet Bag Filter Effective Pulsing Distance)

  • 손정삼;서정민;박정호
    • 한국환경과학회지
    • /
    • 제32권8호
    • /
    • pp.555-561
    • /
    • 2023
  • A study is to predict the effective pulsing distance following to the pulsing pressure, nozzle diameter, filtration velocity using numercial analysis techniques and use it as an efficient operation condition and economic data for on-line type pulse air jet bag filter. Filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the primary experiments using coke dust. For CFD simulation, analysis pulsing characteristics about nozzle diameter, filtration velocity and pulsing pressure. The maximum pulsing length of on-line type pulse air jet bag filter, in 10mm nozzle, filtration velocity 1.5m/min and pulsing pressure 5 bar conditions, is 2,285 mm, maximum length is 76.2% of the total filter bag, which is sufficient to pulsing. In 12mm nozzle, pulsing pressure 5 bar and filtration area 1.22 m2 conditions, the maximum pulsing length of on-line type pulse air jet bag filter is 1,744~2,952 mm, and the maximum length is 2,952 mm indicates pulsing air can be reached to the bottom of filter bag. When the nozzle diameter is increased 8mm to 10mm, maximum pulsing length is extended 40~47%, and increased 10mm to 12 mm, maximum pulsing length is extended 10~17%. For effective pulsing, over the 5bar of pulsing pressure and larger than 10 mm of nozzle diameter are required.

충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측 (Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters)

  • 장경민;정은상;서정민
    • 한국환경과학회지
    • /
    • 제29권5호
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

충격기류식 여과집진장치의 운전조건 변화에 따른 적정 탈진주기 및 탈진압력 설정 (Prediction of Pulse Pressure and Pulse Interval of Change in Operation Conditions of a Pulse Air Jet Bag Filter)

  • 이덕기;임우택;조재환;최금찬;신현무;장성호;서정민
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.349-358
    • /
    • 2018
  • In this study, using coke dust from ironwork, the pulse pressure on a pulse air jet bag filter was investigated considering the influence of the pressure loss due to filtration velocity and pressure intervals. The research on the optimal pulse pressure prediction of a pulse air jet type bag filter using coke dust showed the following results. Pressure loss volatility produced by the pulse pressure under low dust concentration(0.5, $1g/m^3$) and low face velocity(1.25 m/min) was less than $10mmH_2O$. This suggests that the pulse pressure has a low impact on the pressure loss. In contrast, pressure loss volatility under high dust concentration($3g/m^3$) and high face velocity(1.75 m/min) was $25mmH_2O$. Therefore, pulse pressure with high dust concentration and high face velocity has a strong influence on the pressure loss volatility, compared to the condition of low dust concentration and low face velocity. The optimal pulse pressure of inlet dust concentration($0.5g/m^3$) was $6kg/cm^2$ under the same face velocity(1.75 m/min). As concentration increased from 1 to $2g/m^3$, the pulse pressure gradually reached $5kg/cm^2$ thus indicating that the pulse pressure($5kg/cm^2$) is pertinent at a high concentration($3g/m^3$). The pulse intervals: 20, 25 and 30 sec, which are relatively longer than 10 and 15 sec, corresponded to high pressure loss volatility produced by the pulse pressure. Furthermore, low pressure loss volatility was noted at $5kg/cm^2$ of the overall pulse pressure.

충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구 (A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter)

  • 서정민;최금찬;박정호
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.