• Title/Summary/Keyword: Pulse interval

Search Result 249, Processing Time 0.024 seconds

A Study on the Effects of Fuel Rail Pressure and Engine Speed on Gas Fuel System (연료레일 압력과 엔진 속도가 가스연료 시스템에 미치는 영향에 관한 연구)

  • Kwak, Youn-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.579-585
    • /
    • 2018
  • This study is to figure out the fuel injection characteristics according to the injection pressure and engine speed in the fuel supply system for gas fuel. The fuel rail pressure was from 1.5 to 6.0 bar by 1.5 bar increment and engine speed was set 1,000 ~ 6,000 RPM at interval of 1000 RPM. Considering the real engine operation, the injection pulse width was set 2.5ms, 5.0ms, and 13.0ms which correspond low, mid and high load condition respectively. In conclusion, in case of 100cc fuel rail, 4.5 bar of injection pressure showed best performance and the minimum required injection quantity 53cc which guarantees engine output can be obtained in each 1000~ 6000 rpm engine speed.

Pulmonary Vascular Changes in Systemic Pulmonary Anastomosis:An Experimental Study (폐동맥-쇄골하동맥 문합시의 폐동맥 변화에 관한 실험적 연구)

  • 박영관
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.91-106
    • /
    • 1970
  • Two groups of left pulmonary-subclavian artery anastomosis were done in 26 adult mongorel dogs. For the first group. the distal end of the subclnvian artery was nnastomosed to the side of the left pulmonary artery, and for the second group, the subclavian end wns anastomosed to the proximal end of the left lower lobe pulmonary artery. Among them, 6 died of bleeding or anesthetic failure during the day of operation, 10 survived 1 to 106 days and the other 10 were sacrificed at various interval. To investigate the relationship between hemodynamic stress and temporal evolution of the pulmonary vascular lesions. the pulmona try and femoral artery pressures, arteriogram and pathohistological specimens were obtained. The following results were obtained. 1. The postoperative pulmonary artery pressures were within normal limits except 2 dogs in the first group, but in nil 12 dogs of the second group, they were in moderate to maked pulmonary hypertension level. 2 After subclavian pulmonary anastomosis, both groups dogs showed increased femond artery pulse pressure. 3. The pulmonary vascular changes were more severe and appeared earlier in the second group dogs compared with the first group.4. The earliest vascular changes appeared in the media of the small muscular arteries and arterioles. 5. Various vascular chaDges were produced in 2 or 3 months. Thereafter, the changes were stationary. 6. Among the first group, two long-term servivors (No. 705 & 713) which had normal pulmonary artery pressure under the anesthesia, also showed various vascular changes as other pulmonary hypertensive dogs. 7. In the early stage medial hypertrophy. interruptio~l of elastic lamellae were found in the small muscular arteries and arterioles, which were followed by intimal proliferation and thrombosis. These findings may suggest some evidences of trauma to the vessels. 8. Pulmonary arteriograms showed irregularity of the intima of the large and medium sized arteries, abrupt ending of some of the small arteries and narrowing of the anastomosis.

  • PDF

Temperature and Frequency Dependences of Ultrasonic Properties in Commercial MC Nylon Polymers (상용 MC Nylon계 고분자 재료에서 초음파 특성의 온도 및 주파수 의존성)

  • Kim, Myung Deok;Kim, Yong Tae;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.509-517
    • /
    • 2012
  • In the present study, temperature and frequency dependences of ultrasonic properties such as attenuation coefficient and phase velocity was investigated for six kinds of commercial MC-Nylon polymer samples. The ultrasonic properties of the samples were measured by using a pulse transmission method in water over a broadband frequency range of 2 to 8 MHz. Water temperature was varied from 10 to $60^{\circ}C$ with the $10^{\circ}C$ interval. The attenuation coefficients of the samples increased with the frequency and the exponent n of frequency dependence ranged within 1.16 to 1.44, slightly deviating from the linear dependence (n=1). The phase velocities of the samples exhibited negative dispersion, i.e., decreasing velocity with increasing frequency, except for ivory sample at $60^{\circ}C$. The frequency-dependent phase velocities of the samples showed the decreasing tendency with increasing temperature.

Intrusive Phases and Igneous Pricesses in the Yeongju Batholith (영주저반의 관입상과 화성과정)

  • 황상구
    • Economic and Environmental Geology
    • /
    • v.32 no.6
    • /
    • pp.669-688
    • /
    • 1999
  • The Yeongju granitoid batholith is a plutonic complex of huge area (1180km2) intruding the metamorphic rocks of the Yeongnam massif. The batholith, which is divided into fivelithofacies, consists of three separate plutons. The oldest Buseok pluton comprises four lithofacies: hornblende biotite tonalite, porphyrotoc biotite granodiorite, equigranular biotite grandiorite and biotite granite. The middle Chunyang pluton has been called as Chunyang granite that ranges in compostion from granodiorite to granite. The youngest Jangsu pluton is intrusions that has lithofacies of two mica granite. The contact between Buseok pluton and the rest two plutons shows obvious intrusive relations, but relation between the Chunyang and the Jangsu pluton is far away, so gives no indication of relative ages. Changes in nextures and micristructures, as well as in the mineral contents, take place between rock types og the plutons. only the Buseok pluton shows faliations of two type: magmatic foliation and regional mylonal foliation. K-Ar age deteminations fall into 171.7$\pm$3.2~162.3$\pm$3.1 Ma in the Buseok pluton, 153.9$\pm$2.9 Ma in the Chunyang pluton and 145.3$\pm$2.7 Ma in the jangsu Pluton. The batholith presents three separate intrusive phases which range in composition from tonalite to granite to granite. Each intrusive phase apperars to have been intruded in a pulse from an underlying, differentiating magma. The petrochemical data showthat three plutons are within the diagnostic range for continental arc orogenic tectonic setting, whereas Jangsu pluton approaches postorogenic setting. The data suggest that three plutons are calc-aclkalline series, and that temporal compositional variations change progerssively from tonalite through grandiorite to granite between the intrusive phases. so we consider that the magmas for all the phases were probably derived from a differentiation by fractional crystallization of a parental magma. The tonalite magma of the Buseok phase was tapped was tapped from a chamber deep in the crust, and then would have to rise at a rapid rate to its final level of emplacement. The tonalite magma in the chamber was gradually enolved through granodiorite magma into granite magma by fractional crystallization. The magmas of the younger phases were respectively tapped with temporal interval from a evolved magma of the chamber that rose into a shallower lever in the crust, and rose to their present level of emplacement.

  • PDF

A Study on Compensation of Amplitude in Multi Pulse (멀티펄스의 진폭보정에 관한 연구)

  • Lee, See-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4119-4124
    • /
    • 2011
  • In a MPC coding using excitation source of voiced and unvoiced, it would be a distortion of speech waveform in case of increasing or decreasing of speech signal amplitude in a frame. This is caused by normalization of synthesis speech signal in the process of restoration the multi-pulses of representation section. To solve this problem, this paper present a method of amplitude compensation(AC-MPC) in a multi-pulses each pitch interval in order to reduce distortion of speech waveform. I was confirmed that the method can be synthesized close to the original speech waveform. And I evaluate the MPC and AC-MPC using amplitude compensation method. As a result, SNRseg of AC-MPC was improved 0.7dB for female voice and 0.7dB for male voice respectively. Compared to the MPC, SNRseg of AC-MPC has been improved that I was able to control the distortion of the speech waveform finally. And so, I expect to be able to this method for cellular phone and smart phone using excitation source of low bit rate.

Ultra low-power active wireless sensor for structural health monitoring

  • Zhou, Dao;Ha, Dong Sam;Inman, Daniel J.
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.675-687
    • /
    • 2010
  • Structural Health Monitoring (SHM) is the science and technology of monitoring and assessing the condition of aerospace, civil and mechanical infrastructures using a sensing system integrated into the structure. Impedance-based SHM measures impedance of a structure using a PZT (Lead Zirconate Titanate) patch. This paper presents a low-power wireless autonomous and active SHM node called Autonomous SHM Sensor 2 (ASN-2), which is based on the impedance method. In this study, we incorporated three methods to save power. First, entire data processing is performed on-board, which minimizes radio transmission time. Considering that the radio of a wireless sensor node consumes the highest power among all modules, reduction of the transmission time saves substantial power. Second, a rectangular pulse train is used to excite a PZT patch instead of a sinusoidal wave. This eliminates a digital-to-analog converter and reduces the memory space. Third, ASN-2 senses the phase of the response signal instead of the magnitude. Sensing the phase of the signal eliminates an analog-to-digital converter and Fast Fourier Transform operation, which not only saves power, but also enables us to use a low-end low-power processor. Our SHM sensor node ASN-2 is implemented using a TI MSP430 microcontroller evaluation board. A cluster of ASN-2 nodes forms a wireless network. Each node wakes up at a predetermined interval, such as once in four hours, performs an SHM operation, reports the result to the central node wirelessly, and returns to sleep. The power consumption of our ASN-2 is 0.15 mW during the inactive mode and 18 mW during the active mode. Each SHM operation takes about 13 seconds to consume 236 mJ. When our ASN-2 operates once in every four hours, it is estimated to run for about 2.5 years with two AAA-size batteries ignoring the internal battery leakage.

Central Venous Catheterization before Versus after Computed Tomography in Hemodynamically Unstable Patients with Major Blunt Trauma: Clinical Characteristics and Factors for Decision Making

  • Kim, Ji Hun;Ha, Sang Ook;Park, Young Sun;Yi, Jeong Hyeon;Hur, Sun Beom;Lee, Ki Ho
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.135-142
    • /
    • 2018
  • Purpose: When hemodynamically unstable patients with blunt major trauma arrive at the emergency department (ED), the safety of performing early whole-body computed tomography (WBCT) is concerning. Some clinicians perform central venous catheterization (CVC) before WBCT (pre-computed tomography [CT] group) for hemodynamic stabilization. However, as no study has reported the factors affecting this decision, we compared clinical characteristics and outcomes of the pre- and post-CT groups and determined factors affecting this decision. Methods: This retrospective study included 70 hemodynamically unstable patients with chest or/and abdominal blunt injury who underwent WBCT and CVC between March 2013 and November 2017. Results: Univariate analysis revealed that the injury severity score, intubation, pulse pressure, focused assessment with sonography in trauma positivity score, and pH were different between the pre-CT (34 patients, 48.6%) and post-CT (all, p<0.05) groups. Multivariate analysis revealed that injury severity score (ISS) and intubation were factors affecting the decision to perform CVC before CT (p=0.003 and p=0.043). Regarding clinical outcomes, the interval from ED arrival to CT (p=0.011) and definite bleeding control (p=0.038), and hospital and intensive care unit lengths of stay (p=0.018 and p=0.053) were longer in the pre-CT group than in the post-CT group. Although not significant, the pre-CT group had lower survival rates at 24 hours and 28 days than the post-CT group (p=0.168 and p=0.226). Conclusions: Clinicians have a tendency to perform CVC before CT in patients with blunt major trauma and high ISS and intubation.

Multiple Access Capability of Digital IoT Doorlock System for Smart Building (스마트빌딩용 디지털 IoT 도어락 시스템의 다중접속 능력)

  • Lee, Sun-Yui;Sun, Young-Ghyu;Sim, Issac;Hwang, Yu-Min;Yoon, Sung-Hoon;Cha, Jae-Sang;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2018
  • This paper proposes multiple access method for smart doorlock system using VLC(Visible Light Communication) with color grid modulation method. The proposed method is to connect multiple visible light signals using color grid modulation method in order to recognize and authenticate multiple users accessing doorlock. In order to enable visible light multiple access with existing infrastructure, the symbol energy interval of signal should be maximized. Thus, performance of system in VLC channel is measured by modulating symbols based on the proposed method. We confirm the actual channel test results of the modulated signal to implement doorlock system that recognizes the number of multiple access users.

Mechanical Properties and Frost Resistance of Concrete with Steel and Nylon Fibers (강섬유 및 나일론섬유를 적용한 콘크리트의 역학적 성능 및 내동해성 평가)

  • Dong-Gyou, Kim;Seung-Tae, Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.386-394
    • /
    • 2022
  • In this study, the mechanical properties and frost resistance of concrete with steel and nylon fibers were experimentally investigated. Both of OPC concrete with 100 % ordinary portland cement and SGC concrete replaced with 50 % GGBFS were manufactured to evaluate effects of fibers to the performance of concrete. Compressive and split tensile strength, ultrasonic pulse velocity and surface electric resistivity measurements of concrete were carried out at a predetermined interval. In addition, the freezing & thawing resistance of concrete in accordance with ASTM C666 standard was also examined. As a result, it is seemed that the effect of fibers was remarkable to improve the mechanical properties and frost resistance of concrete, especially for the concrete incorporating steel fiber.

Safe Discharge Criteria After Curative Gastrectomy for Gastric Cancer

  • Guner, Ali;Kim, Ki Yoon;Park, Sung Hyun;Cho, Minah;Kim, Yoo Min;Hyung, Woo Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.395-407
    • /
    • 2022
  • Purpose: This study aimed to investigate the relationship between clinical and laboratory parameters and complication status to predict which patients can be safely discharged from the hospital on the third postoperative day (POD). Materials and Methods: Data from a prospectively maintained database of 2,110 consecutive patients with gastric adenocarcinoma who underwent curative surgery were reviewed. The third POD vital signs, laboratory data, and details of the course after surgery were collected. Patients with grade II or higher complications after the third POD were considered unsuitable for early discharge. The performance metrics were calculated for all algorithm parameters. The proposed algorithm was tested using a validation dataset of consecutive patients from the same center. Results: Of 1,438 patients in the study cohort, 142 (9.9%) were considered unsuitable for early discharge. C-reactive protein level, body temperature, pulse rate, and neutrophil count had good performance metrics and were determined to be independent prognostic factors. An algorithm consisting of these 4 parameters had a negative predictive value (NPV) of 95.9% (95% confidence interval [CI], 94.2-97.3), sensitivity of 80.3% (95% CI, 72.8-86.5), and specificity of 51.1% (95% CI, 48.3-53.8). Only 28 (1.9%) patients in the study cohort were classified as false negatives. In the validation dataset, the NPV was 93.7%, sensitivity was 66%, and 3.3% (17/512) of patients were classified as false negatives. Conclusions: Simple clinical and laboratory parameters obtained on the third POD can be used when making decisions regarding the safe early discharge of patients who underwent gastrectomy.