• Title/Summary/Keyword: Pulse interval

Search Result 249, Processing Time 0.027 seconds

Indirect Electrochemical Oxidation of Phenol by Ce4+, Controlling Surface Insulation of Au Electrode

  • Pyo, Myoung-Ho;Moon, Il-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.899-902
    • /
    • 2005
  • Indirect electrochemical oxidation of phenol by $Ce^{4+}$ was investigated in sulfuric acid solutions. It was found that electrode fouling during oxidation of phenol can be controlled by adjusting the time interval (TI) of double potential steps (DPSs). While the electroactivity was greatly decreased after several DPSs of a relatively long TI, repeated DPSs with a short potential pulse showed substantial amounts of electroactivity after a few hundreds or thousands DPS, suggesting that the formation of an insulating layer can be controlled by adjusting a potential program. Effectiveness of the consecutive application of DPSs for phenol decomposition was confirmed by GC-MS.

A novel PWM control of Full-bridge Inverters for Microprocessor Implementation (마이크로프로세서 구현에 의한 전파 브리지 인버터의 새로운 PWM 제어)

  • 전칠환;이수원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.283-288
    • /
    • 2000
  • This paper proposes a novel Pulse Width Modulation (PWM) method for microprocessor implementation of full-bridge PWM inverters. In the method, the period of unipolar full-bridge inverters is divided equally into the frequency modulation ratio and the reference fundamental amplitude and the inverter output fundamental amplitude are compared. Using this method, the turn-on time computation of each interval is very favored for the microprocessor implementation. The harmonic analysis shows that the harmonics can be ignored when the modulation ratio is enough large. The simulation and experimental results show the effectiveness of the proposed algorithms.

  • PDF

A Study on Development of Oscillator Measurement Device Using Double Edge Time Interval Frequency Counter (더블 에지타임 인터벌 카운터를 이용한 발진기특정 장치개발에 관한 연구)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1386-1392
    • /
    • 2009
  • In this paper, we have developed the test equipment to measure performance of oscillator using Double Side Edge Trigger(DSET). This DSET increases counting number of micro pulse by frequency counter, which will successfully reduce the half measuring time to comparison with the existing counter by using DSET. This new concept of performance measuring equipment provides a high productivity and performance improvement.

Field Weakening Control of IPMSM Based Next Generation High Speed Railway System (IPMSM이 적용된 차세대 고속전철 시스템의 약계자 제어)

  • Jin, Kang-Hwan;Yi, Du-Hee;Kim, Sung-Je;Chang, Chin-Young;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.351-357
    • /
    • 2010
  • In this paper, a vector control of the IPMSM drives for the next generation domestic high speed railway system is presented. The applied control method uses one pulse mode field weakening control in constant power region, and maximum torque control per ampere control in constant torque region considering current and voltage limits. An overmodulation control interval is inserted to improve the transient characteristics during transition period of the control modes. Simulation programs based on Matlab/Simulink are developed. Finally the designed system is verified by simulation and their characteristics are analyzed by the simulation results.

A New Space Vector Random Position PWM Scheme (새로운 공간벡터 Random Position PWM기법)

  • Kim, Hoe-Geun;Lim, Young-Cheol;Na, Seok-Hwan;Jung, Young-Gook
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.168-174
    • /
    • 2001
  • In this paper, a new space vector RPPWM (Random Position PWM) is proposed. In the proposed RPPWM, each of three phase pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of voltage, current as in the case of randomly changed switching frequency. To verify the validity of the proposed RPPWM, simulation study was tried using Matlab/simulink. The main model described in Simulink block diagrams includes the space vector modulation block, pulse position randomization block, inverter block, 3 phase induction motor block, and so on. By the simulation study, the harmonics of the output voltage, and the current of inverter are predicted in different PWM methods- SVPWM, LLPWM, proposed RPPWM.

  • PDF

Determination of Physiological Changes according to Nitrous Concentration and Application Method (아산화질소 농도 및 적용방법에 따른 생리학적 변화)

  • Lee, Daewoo;Han, Jihoon;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.435-442
    • /
    • 2016
  • The aim of this study was to analyze physiological changes, clinical and subjective symptoms by different $N_2O$ concentrations and administration method. This study surveyed 65 men and women ages 19 to 35 and all subjects were healthy volunteers, with no contraindication for use of $N_2O$ sedation. The $N_2O$ sedation was carried out in a way that increases by 10 percent to one-minute interval or increases at once the desired level. Each method was required to reach 30 or 50 percent $N_2O$ concentration. The way to gradually raise the $N_2O$ concentration can reduce the risk by decreasing the pulse reduction rate at the same $N_2O$ concentration. $SpO_2$ has no statistical significance according to $N_2O$ concentration and method of administration. Pulse rate reduced significantly when 50% $N_2O$ increase at once during sedation and 100% $O_2$ after 5 minutes. The way to gradually raise the $N_2O$ concentration is safe for reducing pulse rate.

Extraction of the ship movement information by a radar target extractor (Radar Target Extractor에 의한 선박운동정보의 추출에 관한 연구)

  • Lee, Dae-Jae;Kim, Kwang-Sik;Byun, Duck-Soo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.249-255
    • /
    • 2002
  • This paper describes on the extraction of ship's real-time movement information using a combination full-function ARPA radar and ECS system that displays radar images and an electronic chart together on a single PC screen. The radar target extractor(RTX) board, developed by Marine Electronics Corporation of Korea, receives radar video, trigger, antenna bearing pulse and heading pulse signals from a radar unit and processes these signals to extract target information. The target data extracted from each pulse repetition interval in DSPs of RTX that installed in 16 bit ISA slot of a IBM PC compatible computer is formatted into a series of radar target messages. These messages are then transmitted to the host PC and displayed on a single screen. The position data of target in range and azimuth direction are stored and used for determining the center of the distributed target by arithmetic averaging after the detection of the target end. In this system, the electronic chart or radar screens can be displayed separately or simulaneously and in radar mode all information of radar targets can be recorded and replayed In spite of a PC based radar system, all essential information required for safe and efficient navigation of ship can be provided.

A Study on PCFBD-MPC in 8kbps (8kbps에 있어서 PCFBD-MPC에 관한 연구)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.18 no.5
    • /
    • pp.17-22
    • /
    • 2017
  • In a MPC coding using excitation source of voiced and unvoiced, it would be a distortion of speech waveform. This is caused by normalization of synthesis speech waveform of voiced in the process of restoration the multi-pulses of representation section. This paper present PCFBD-MPC( Position Compensation Frequency Band Division-Multi Pulse Coding ) used V/UV/S( Voiced / Unvoiced / Silence ) switching, position compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. Also, I was implemented that the PCFBD-MPC( Position Compensation Frequency Band Division-Multi Pulse Coding ) system and evaluate the SNRseg of PCFBD-MPC in coding condition of 8kbps. As a result, SNRseg of PCFBD-MPC was 13.4dB for female voice and 13.8dB for male voice respectively. In the future, I will study the evaluation of the sound quality of 8kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or a smart phone.

Changes of Postprandial Blood Pressure of Elderly in Nursing Homes by Position (시설 거주 노인의 식사 후 체위에 따른 혈압의 변화양상)

  • Son, Jung Tae;Lee, Eunjoo;Park, Ji Hyun
    • 한국노년학
    • /
    • v.32 no.3
    • /
    • pp.689-701
    • /
    • 2012
  • The purposes of this study were to identify the changes of postprandial blood pressure and pulse rates of elderly living in nursing homes by time and position after a meal. Blood pressure and pulse rates of 141 elderly aged over 65 years were measured at before the meal to 90 minutes after the meal by 15 min. interval. Data were analyzed by descriptive statistics, repeated measures of ANOVA, ANCOVA, and t-test using the SPSS program. There were no significant differences in change of systolic blood pressure and pulse rates by time between sitting group and lying group after meal. The biggest drops in systolic pressure in sitting and lying position were occurred at 30 min and 45min respectively after the meal. There were no significant change in pulse rates except for the immediately after meal in lying position. To prevent complications of postprandial blood pressure reduction, nurses should carefully monitor blood pressure of elderly in lying position at least from 30 min. till to 90 min. after the meal.

A Study on Improving Pitch Search for Vocoder (보코더에서 피치검색 성능개선에 관한 연구)

  • Baek, Geum-Ran;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.7
    • /
    • pp.419-426
    • /
    • 2012
  • The pitch searching is a vital process in a vocoder. Generally, the method of pitch searching is employed after highlighting the periodicity, where a correlation is identified with the signal by changing the interval of two pulses. When the correlation value reaches the peak, the pitch can be found by the pulse interval because it is the repetition interval with most striking period. However if the identified period happens to be one of half period, double period or triple period, this cannot be considered as the pitch period. Many methods were suggested to solve this problem. An inaccurate pitch could be obtained as well, when there is an interval where signal amplitude is not constant but varies abruptly in the frame. To solve this matter, searching the pitch by dividing a frame into various subframes is adopted, but too much calculation has to be followed while it leads the correct value. This paper suggests an algorithm to resolve these two problems. First, to search the pitch after advance correction of the signal energy level with an estimated overall energy change ratio in the frame before pitch search to reduce half period, double period and triple period is suggested. Second, to vary the number of subframes by predicting the amplitude change rate in the frame by the energy ratio obtained by the above-mentioned method is advised. If these two methods are applied, the pitch searching time can be reduced and the general pitch searching performance can be improved without affecting the sound quality in the synthesized signal.