• Title/Summary/Keyword: Pulse injection

Search Result 245, Processing Time 0.021 seconds

A study on the nonvolatile memory characteristics of MNOS structures with double nitride layer (2층 질하막 MNOS구조의 비휘발성 기억특성에 관한 연구)

  • 이형욱
    • Electrical & Electronic Materials
    • /
    • v.9 no.8
    • /
    • pp.789-798
    • /
    • 1996
  • The double nitride layer Metal Nitride Oxide Semiconductor(MNOS) structures were fabricated by variating both gas ratio and nitride thickness, and by duplicating nitride deposited and one nitride layer MNOS structure to improve nonvolatile memory characteristics of MNOS structures by Low Pressure Chemical Vapor Deposition(LPCVD) method. The nonvolatile memory characteristics of write-in, erase, memory retention and degradation of Bias Temperature Stress(BTS) were investigated by the homemade automatic .DELTA. $V_{FB}$ measuring system. In the trap density double nitride layer structures were higher by 0.85*10$^{16}$ $m^{-2}$ than one nitride layer structure, and the AVFB with oxide field was linearly increased. However, one nitride layer structure was linearly increased and saturated above 9.07*10$^{8}$ V/m in oxide field. In the erase behavior, the hole injection from silicon instead of the trapped electron emission was observed, and also it was highly dependent upon the pulse amplitude and the pulse width. In the memory retentivity, double nitrite layer structures were superior to one nitride layer structure, and the decay rate of the trapped electron with increasing temperature was low. At increasing the number on BTS, the variance of AVFB of the double nitride layer structures was smaller than that of one nitride layer structure, and the trapped electron retention rate was high. In this paper, the double nitride layer structures were turned out to be useful in improving the nonvolatile memory characteristics.

  • PDF

The change of signaling pathway on the electrical stimulated contraction in streptozotocin-induced bladder dysfunction of rats

  • Han, Jong Soo;Min, Young Sil;Kim, Gil Hyung;Chae, Sang-hyun;Nam, Yoonjin;Lee, Jaehwi;Lee, Seok-Yong;Sohn, Uy Dong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.5
    • /
    • pp.577-584
    • /
    • 2018
  • Bladder dysfunction is a common complication of diabetes mellitus (DM). However, there have been a few studies evaluating bladder smooth muscle contraction in DM in the presence of pharmacological inhibitors. In the present study, we compared the contractility of bladder smooth muscle from normal rats and DM rats. Furthermore, we utilized pharmacological inhibitors to delineate the mechanisms underlying bladder muscle differences between normal and DM rats. DM was established in 14 days after using a single injection of streptozotocin (65 mg/kg, intraperitoneal) in Sprague-Dawley rats. Bladder smooth muscle contraction was induced electrically using electrical field stimulation consisting of pulse trains at an amplitude of 40 V and pulse duration of 1 ms at frequencies of 2-10 Hz. In this study, the pharmacological inhibitors atropine (muscarinic receptor antagonist), U73122 (phospholipase C inhibitor), DPCPX (adenosine $A_1$ receptor antagonist), udenafil (PDE5 inhibitor), prazosin (${\alpha}_1$-receptor antagonist), verapamil (calcium channel blocker), and chelerythrine (protein kinase C inhibitor) were used to pretreat bladder smooth muscles. It was found that the contractility of bladder smooth muscles from DM rats was lower than that of normal rats. In addition, there were significant differences in percent change of contractility between normal and DM rats following pretreatment with prazosin, udenafil, verapamil, and U73122. In conclusion, we suggest that the decreased bladder muscle contractility in DM rats was a result of perturbations in $PLC/IP_3$-mediated intracellular $Ca^{2+}$ release and PDE5 activity.

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

A clinical comparative study between conventional and camouflaged syringes to evaluate behavior and anxiety in 6-11-year-old children during local anesthesia administration-a novel approach

  • Melwani, Anjana M;Srinivasan, Ila;Setty, Jyothsna V;Murali, Krishna D.R.;Pamnani, Sunaina S;Lalitya, Dandamudi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • Background: The sight of dental injection can bring about severe anxiety in children. Therefore, an alternative method that is convenient, effective, and keeps the needle hidden making it child friendly is necessary. The objective of the study was to compare the efficacy of a camouflaged syringe and conventional syringe on behavior and anxiety in 6-11-year-old children during local anesthesia administration. Methods: The study was a randomized, crossover clinical study including 30 children. Children were separated into two groups. Group 1 consisted of 15 children aged 6-8 years while group 2 consisted of 15 children aged 9-11 years. This study involved two sessions wherein all the children were injected using conventional and camouflaged syringes in separate sessions. Their behavior was assessed using the Faces, Legs, Activity, Cry, Consolability (FLACC) behavior pain scale and anxiety was assessed by measuring changes in pulse rate. Patient and operator preferences were compared. Results: The results showed a lower mean change in pulse rate and FLACC scores in the camouflaged group, suggesting a positive behavior and lesser anxiety with camouflaged syringes than with conventional syringes. Conclusions: The use of camouflaged syringes for anesthesia was demonstrated to be effective in improving the behavior of children and decreasing their anxiety, and is therefore recommended as an alternative to the use of conventional syringes for local anesthesia.

Failure Case Studies of Sensors for Electronic Controlled Engine in LPG Vehicle (LPG 자동차에서 전자제어엔진용 센서의 고장사례에 관한 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • The purpose of this paper analyzes and investigates the failure case studies of electronic control sensors for a LP gas engine. The malfunction of crank angle sensor, which controls a fuel injection volume of LP gas, displays an irregular and non-uniform pulse wave form. The pulse form, which is related to the noise of the crank angle sensor, displays at the rectangular peak with a saw-toothed shape and is intermittently generated with a level of 2.46V noise signal. The malfunction of No. 1 TDC sensor in which is caused from the internal disorder affects to the reduction of engine power and engine stop suddenly. If the malfunction of oxygen sensor is occurred due to a wiring problem of a sensor connector, the LP gas vehicle may produce a shaking and disharmony of an engine because of no signal supply from the oxygen sensor. The air cleaner replica produces the clogging of continuous supply of fresh air. This may cause the retardation of vehicle acceleration and engine disharmony intermittently.

Development of SSPA-based X-band Transmitter with Graceful Degradation (점진적 성능저하 기능을 가지는 X-대역 SSPA 송신장치 개발)

  • Song, Hyeong-Min;Kim, Ji-Deok;Kang, Hyun-Chul;Song, Jae-Gyeong;Park, Chul-Soon;Rhee, Kye-Jin;Lee, Choung-Hyun;Kim, Dong-Gil
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.853-862
    • /
    • 2019
  • In this paper, we designed a 4.5kW X-band SSPA transmitter to replace the TWTA search radar transmitter with low MTBF and high maintenance cost. The transmitter is designed for the performance of over 520W average transmission output and 4.0kW maximum transmission output. In particular, by implementing a graceful degradation, it is designed to maintain better performance than conventional TWTA transmitter up to 40% (13 assembly modules) failure level of 200W power amplifier assembly. Through an experiment on the effective range of X-band, the performance of proposed transmitter verified the values of the maximum transmission output 6.1kW, spurious output 69.16dBc, RF pulse rising time 15.2ns and RF pulse falling time 16.3ns. The experiment confirmed the change of output power according to the graceful degradation due to fault injection.

Picosecond Mid-Infrared 3.8 ㎛ MgO:PPLN Optical Parametric Oscillator Laser with High Peak Power

  • Chen, Bing-Yan;Wang, Yu-Heng;Yu, Yong-Ji;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.186-190
    • /
    • 2021
  • In this study, a compact, picosecond, mid-infrared 3.8 ㎛ MgO:PPLN optical parametric oscillator (OPO) laser output with high peak power is realized using a master oscillator power amplifier (MOPA) 1 ㎛ solid-state laser seeded by a picosecond fiber laser as the pump source. The pump source was a 50 MHz and 10 ps fiber seed source. After AOM pulse selection and two-stage solid-state amplification, a 1,064 nm laser output with a repetition frequency of 1-2 MHz, pulse width of 9.5 ps, and a maximum average power of 20 W was achieved. Furthermore, a compact short cavity with a unsynchronized pump is adopted through the design of an OPO cavity structure. When the injection pump power was 15 W and the repetition frequency was 1 MHz, the average output power of idler light was 1.19 W, and the corresponding peak power was 119 kW. The optical conversion efficiency was 7.93%. When the repetition frequency was increased to 2 MHz, the average output power of idler light was 1.63 W, the corresponding peak power was 81.5 kW, and the optical conversion efficiency was 10.87%. At the same time, the output wavelength was measured at 3,806 nm, and the beam quality was MX2 = 3.21 and MY2 = 3.34.

Thermodynamic simulation and structural optimization of the collimator in the drift duct of EAST-NBI

  • Ning Tang;Chun-dong Hu;Yuan-lai Xie;Jiang-long Wei;Zhi-Wei Cui;Jun-Wei Xie;Zhuo Pan;Yao Jiang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4134-4145
    • /
    • 2022
  • The collimator is one of the high-heat-flux components used to avoid a series of vacuum and thermal problems. In this paper, the heat load distribution throughout the collimator is first calculated through experimental data, and a transient thermodynamic simulation analysis of the original model is carried out. The error of the pipe outlet temperature between the simulated and experimental values is 1.632%, indicating that the simulation result is reliable. Second, the model is optimized to improve the heat transfer performance of the collimator, including the contact mode between the pipe and the flange, the pipe material and the addition of a twisted tape in the pipe. It is concluded that the convective heat transfer coefficient of the optimized model is increased by 15.381% and the maximum wall temperature is reduced by 16.415%; thus, the heat transfer capacity of the optimized model is effectively improved. Third, to adapt the long-pulse steady-state operation of the experimental advanced superconducting Tokamak (EAST) in the future, steady-state simulations of the original and optimized collimators are carried out. The results show that the maximum temperature of the optimized model is reduced by 37.864% compared with that of the original model. The optimized model was changed as little as possible to obtain a better heat exchange structure on the premise of ensuring the consumption of the same mass flow rate of water so that the collimator can adapt to operational environments with higher heat fluxes and long pulses in the future. These research methods also provide a reference for the future design of components under high-energy and long-pulse operational conditions.

A comparative evaluation of peppermint oil and lignocaine spray as topical anesthetic agents prior to local anesthesia in children: a randomized clinical trial

  • Harika Petluru;SVSG Nirmala;Sivakumar Nuvvula
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2024
  • Background: In pediatric dentistry, fear and anxiety are common among children. Local anesthetics (LA) are widely used to control pain and reduce discomfort in children during dental treatment. Topical anesthetics play a vital role in reducing pain and the unpleasant sensation of a needle puncture in children. Peppermint oil has been extensively used for various diseases. However, its anesthetic properties remain unknown. Peppermint oil, used in mouthwashes, toothpastes, and other topical preparations has analgesic, anesthetic, and antiseptic properties. This study aimed to compare and evaluate pain perception following the topical application of peppermint oil versus lignocaine spray before an intraoral injection in children, aged 8-13 years. Method: Fifty-two children, aged between 8-13 years, who required local anesthesia for dental treatment were divided into two groups of 26 each by simple random sampling (Group 1: 0.2% peppermint oil and Group 2: lignocaine spray). In both groups, physiological measurements (e.g., heart rate) were recorded using pulse oximetry before, during, and after the procedure. Objective pain measurement (Sound Eye Motor (SEM) scale) during administration and subjective measuremeant (Wong-Baker Faces Pain Rating Scale (WBFPRS)) after LA administration were recorded. This was followed by the required treatment of the child. Physiological parameters were compared between the two groups using an independent t-test for intergroup assessment and a paired t-test and repeated-measures ANOVA for intragroup comparisons. The Mann-Whitney U test was used to analyze the pain scores. Results: Intragroup mean heart rates, before, during, and after treatment were statistically significantly different (P < 0.05). However, the intergroup mean pulse rates did not differ significantly between the two groups. The mean WBFPS score in the lignocaine spray group was 4.133 ± 2.06 was statistically different from that of the peppermint oil group (0.933 ± 1.03; P < 0.001*). The mean SEM score was significantly lower in the peppermint oil group than that in the lignocaine spray group (P = 0.006). No negative effects were observed in this study. Conclusion: 0.2% peppermint oil was effective in reducing pain perception.

Content and Educational Needs for Fundamental Nursing Practice (기본간호실습 교육 현황 및 실습교육 필요도)

  • Kim, Kyung-Hee;Chang, Sung-Ok;Kang, Hyun-Sook;Kim, Keum-Soon;Kim, Jong-Im;Kim, Hwa-Soon;Park, Jin-Hee;Eom, Mi-Ran;Youn, Mi-Sun;Lee, Og-Cheol;Won, Jong-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.4
    • /
    • pp.506-519
    • /
    • 2011
  • Purpose: The purpose of this study was to identify content of Fundamental Nursing Practice (FNP) and the educational needs for nursing practice items in schools of nursing. Methods: Participants were 81 professors who were teaching FNP and 166 clinical nurses. The research questionnaire included 148 practice items, which were selected by content analysis of 7 FNP textbooks. Data were collected from May 20 to July 27, 2011 and analyzed using descriptive statistics and t-test with SPSS 17.0. Results: The research findings showed that : 1) the seven items included in the education content of all schools of nursing were putting on sterile gloves, checking radial pulse, checking blood pressure in the arm, Foley catheterization, injection preparation with ampule, intramuscular injection in the buttocks, and mixing intravenous fluid. Fifty items were included in the content in more than 80% of the schools. 2) Educational domains needing emphasis were medication, infection control, health assessment, oxygenation, urinary elimination, activity/positioning, and nutrition. There were significant differences in reported educational needs between professors and clinical nurses for 62.8% of practice items. Conclusions: Results indicated that standardization of FNP education contents using the findings of this study should lead to improvement in quality of FNP education.