• 제목/요약/키워드: Pulse imaging analysis

검색결과 67건 처리시간 0.024초

3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구 (A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer)

  • 강희정;권영상;김달래;김경철;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.

Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

  • Abdala-Junior, Reinaldo;No-Cortes, Juliana;Arita, Emiko Saito;Ackerman, Jerome L.;da Silva, Renan Lucio Berbel;Kim, Jun Ho;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.413-419
    • /
    • 2021
  • Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

Epidural Injection시술시 투시율 변화에 따른 선량비교연구 (Comparative study of dose due to the change of fluoroscopy pulse rate of Epidural Injection treatment time)

  • 서정범;오동훈;이정범;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.21-26
    • /
    • 2013
  • To be investigated and measures to reduce the medical exposure of patients to change the Epidural Injection time Fluoroscopy Pulse Rate in this study. Was conducted in 50 patients who underwent surgery Epidural Injection performed by interventional care of Konkuk University Hospital from January to April 2013. The treatment time with the change of Pulse rate, is measured in minutes fluoroscopy time, and measured the area dose (${\mu}Gym^2$) and depth dose (mGy). Using the Image J program, to measure the PSNR and SNR. The fluoroscopy time as a result surgery, there was no significance in the statistical analysis, and depth dose is 34.3 to 34.9%, was reduced from 35.8 to 38.7% the area dose. It is possible to reduce the appropriate Pulse rate, to reduce the dose without statistical analysis significance fluoroscopy time.

  • PDF

초음파 영상 시스템에서의 해상도 개선을 위한 펄스압축기법에 사용되는 코드에 대한 분석 (Analysis on Code Used in Pulse Compression Method for Improving Resolution of Ultrasound Imaging System)

  • 유양모;이한희;송태경
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.115-116
    • /
    • 1998
  • Pulse echo techniques have been used for the conventional medical ultrasound imaging systems. However, their resolution is limited in the transmitted signal power. To overcome this limit, pulse compression method used in the radar systems was proposed. This system transmits a continuous coded signal and then compresses the received signal into the short and high resolution pulse by using correlator. The reflectors can be detected by cross-correlation between the transmitted signal and the received signal with the depth information. In this paper, we will present a comparative study of the performances of the most common sequences(pseudo-chirp, m-sequences, modified Golay code). The best result for improving resolution is obtained with the modified Golay Code.

  • PDF

대장정격 및 승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구 (The Effects of Sa-Am Acupuncture on Radial Pulse in Healthy Subjects: A Comparative Study of Large Intestine Tonifying and Sedating)

  • 조은;이현
    • Journal of Acupuncture Research
    • /
    • 제31권3호
    • /
    • pp.7-18
    • /
    • 2014
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse in healthy subjects. Methods : Sixty healthy subjects participated in this study, divided into large intestine tonifying acupuncture group, large intestine sedating acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture at Cun, Guan, and Chi in the acupuncture group and in the control group at the same time points. Results : 1. Angle of main peak and magnitude of fourier component significantly changed by integrated analysis of Cun, Guan and Chi. 2. Amplitude of H1, Pulse Power volume / min, elasticity, AIx / HR, Frequency and magnitude of fourier component significantly changed by analysis of Cun, Guan, and Chi. Conclusions : The effect of Sa-Am acupuncture with large intestine tonifying and sedating in healthy human may be observed on time, amplitude, pulse area, augmentation index and fourier components parameters. The parameters analysed in this study may be used to differentiate the effects between Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

  • Lee, Youngjin;Choi, Min Hyeok;Goh, Hee Jin;Han, Dong-Kyoon
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.281-285
    • /
    • 2016
  • The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmol/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.

뇌정위 방사선수술 시스템을 위한 자기공명영상의 공간적 왜곡의 측정 : 모형실험을 통한 연구 (Assessment of Imaging Distortion in Magnetic Resonance Imaging for Stereotactic Radiosurgery: Through Phantom Study)

  • 박선원;한문희;김동규;정현태;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.7-13
    • /
    • 2000
  • 목적: 모형실험을 통하여 자기공명영상의 공간왜곡의 정도를 영상획득방향과 펄스연쇄별로 알아보고 실험 조건에서 공간왜곡이 가장 적은 영상 획득 방향과 펄스 연쇄를 찾고자 하였다. 실험 상 얻어진 가장 공간적 왜곡이 적은 영상법은 뇌정위 방서선수술의 적용시에도 실험한 조건중 가장 공간적 왜곡이 적은 영상법으로 인체적용에 도움이 될 것으로 가정하였다. 대상 및 방법: 아클리로 만든 직육면체에 일정한 간격 (2cm)의 아크릴 원형 막대 지름 4mm)를 배치하여 자기공명영상을 위한 모형을 제작하였다. 모형의 내부를 증류수로 채운 후 Leksell 상업용 감마나이프 G-프레임을 씌우고 모형을 자기공명 영상의 중심에 놓고 축상과 관상면의 T1 SE, T2 SE, T2 FSE, MPRAGE영상을 얻은 뒤 영상분석 프로그램(Lleksell Gamma Plan, Version = 5.10)을 이용하여 공간적 왜곡의 거의 없을 것이라고 가정한 CT 영상에서 측정된 막대간의 거리의 차이를 구하고 이것이 각 영상획득 방법과 펄스 연쇄별로 차이가 나는지 또 영상의 가장자리와 중심부에서 차이가 나는지 paired student t-test를 통하여 분석하였다. MR의 각 단면 영상을 영상분석 프로그램에 인식시키는 과정에서도 프로그램에 내장되어 있는 외부 표식자의 좌표의 위치를 통해서 외부표식자의 좌표의 위치를 통해서 외부표식자를 기준으로한 영상의 공간적 왜곡의 정도가 자동으로 측정된다. 결과: 자기공명영상의 공간적 왜곡은 횡단면 영상에서는 감마나이트의 G-프레임의 외부표식자에 의하여 측정된 결과와 모형실험을 통하여 얻어진 결과에서 모두 뇌정위방서선수술에 이용하기에 허용할 만한 1.5mm 이하의 적은 수준의 왜곡 값을 지니고 있었다. 관상면의 자기공명영상은 외부표식자에 의해 왜곡을 측정했을 때, 감마나이프에 적용하기에는 1.5mm 이상의 공간 왜곡값을 보였으나 왜부표식자에 의한 좌표를 통해 구해진 모형실험의 결과에서는 1.5mm 이하로 공간적 왜곡이 오히려 보정되는 결과를 보였다. 결론: 이 실험을 통하여 임상적으로 주로 사용되는 펄스연쇄와 영상획득방향에서 축상 3D MPRAGE기법이 가장 공간적 왜곡이 적은 영상법 임을 알 수 있었다. 현재 사용되는 MR기기의 공간왜곡의 정도는 모형실험의 결과, 1.5mm 이하 수준으로 매우 적어서 다른 영상법에 비해 매우 우수한 MR의 공간 해상력을 고려하면, 실제 인체에 적용하여 뇌정위 방사선수술시 사용항기에도 타영상기법에 비해 손색없는 영상법이 될 것으로 판단된다.

  • PDF

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥파의 주파수 분석 (A Study on the Effect of Food Intake on Radial Pulse using Fourier Analysis)

  • 임윤경;박광석
    • 대한한의학회지
    • /
    • 제32권4호
    • /
    • pp.139-148
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the effect of food intake on the Fourier components of radial pulse wave. Methods: Thirty-one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Fourier transform was performed and the frequency and amplitude of Fourier components were analyzed. Results: 1. The frequency and the amplitude of Fourier components of radial pulse wave increased significantly after food intake. 2. The frequency of Fourier components increased right after food intake and then gradually decreased as time passed, however the amplitude of Fourier components increased and maintained certain levels and patterns throughout the experimental period of 120 minutes. 3. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations. Conclusions: Food intake exerts an influence on radial pulse wave, resulting in increase of frequency and amplitude of Fourier components. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations.

원발성 월경통 환자와 속발성 월경통 환자의 심박변이도, 체성분, 적외선 체열 촬영, 맥전도 검사 상 특징 비교 고찰 (Comparative Analysis of the Heart Rate Variability, Body Composition, Digital Infrared Thermal Imaging and Electro Pulse Graph Between Primary Dysmenorrhea Patients and Secondary Dysmenorrhea Patients)

  • 이수정;지해리;황덕상;이창훈;장준복;이진무
    • 대한한방부인과학회지
    • /
    • 제32권4호
    • /
    • pp.25-38
    • /
    • 2019
  • Objectives: The purpose of this study is to analysis differences of heart rate variability (HRV), body composition, digital infrared thermal imaging (DITI), and electro pulse graph by whether there are some causes of dysmenorrhea or not. Methods: We studied 89 patients who took at least one test among HRV, Body composition, DITI, and electro pulse graph visiting Kyung Hee University Hospital at Gangdong from March 1, 2014 to May 7, 2019. Results: There were statistically significant differences in Low frequency (LF), LF norm and High frequency norm (HF norm) of HRV between primary dysmenorrhea patients and secondary dysmenorrhea patients. There were statistically significant differences in Body Mass Index (BMI) and body fat percentage of Body composition between two groups. But both BMI were included in normal range. There were no statistically significant difference in DITI results. And there was significant difference of Estimated circulation resistance (ECR) between two groups. Conclusions: The results suggest that hormone imbalance of secondary dysmenorrhea patients can affect HRV results. And because of high ECR, phlegm pathology can be more considered in secondary dysmenorrhea patients. Further study should be conducted to confirm the results of body composition and DITI differences.