• Title/Summary/Keyword: Pulse design

Search Result 1,445, Processing Time 0.026 seconds

Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture Original Articles (산삼 약침이 정상 중년여성의 맥파요인에 미치는 영향)

  • Park, Sang-Wook;Kim, Yi-Soon;Hwang, Won-Deok;Kim, Gyeong-Cheol
    • Journal of Pharmacopuncture
    • /
    • v.14 no.1
    • /
    • pp.35-49
    • /
    • 2011
  • Objectives: The aim of this experiment is to know about Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture. Methods: First 20 Middle Aged women are diagnosed by pulse diagnosis, and then Mountain Cultivated Ginseng Pharmacopuncture(1 injection 20cc) were injected. 30 minutes later, pulse diagnosis again performed. As a result, method of one-group pretest-posttes design were used for evaluation. Results: T(Total pulse cycle) time statistically significant increased on both left and right chon, kwan, cheok. T4 time statistically significant increased on both left and right chon, kwan, cheok. T4-T1/T indexs except left cheokmaek, Right cheokmaek observation area decreased significantly in four sites. Wm(indicating high pressure retention time) indexs increased significantly in the five sites were observed except right chon maek. Conclusions: Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture increased T, T4, Wm and decreased T4-T1/T indexs. The results of this experiment, Mountain Cultivated Ginseng Pharmacopuncture induced to increase the Pulse-wave's stability and strength.

A Study on The State Estimation of The Time-Invariant Linear Systems via The Improved Parameter Estimation Method for The Block Pulse Coefficients (개선된 블록 펄스 계수 추정 기법을 이용한 선형 시불변계의 상태 추정에 관한 연구)

  • Kim, Tai-Hoon;Kim, Jin-Tae;Chung, Je-Wook;Sim, Jae-Seon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.4
    • /
    • pp.137-143
    • /
    • 2002
  • Because Block Pulse functions are used in a variety of fields such as the analysis and controller design of systems, it is necessary to find the more exact value of the Block Pulse series coefficients. This paper presents a method for the state estimation of the time-invariant linear systems via the improved estimation method for the Block Pulse coefficients by using the Simpson's rule. The proposed method using the Simpson's rule improve the accuracy of the Block Pulse coefficients.

An Experimental Study for the 77K Inertance Tube Pulse Tube Cryocooler (77K Inertance tube 맥동관 극저온 냉동기에 관한 연구)

  • Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong
    • 연구논문집
    • /
    • s.29
    • /
    • pp.17-27
    • /
    • 1999
  • The experimental results of the 17K inertance tube pulse tube cryocooler for cooling cryosensors are presented in this paper. In prototype experiments, linear compressor is driven by linear motor, and inertance tubes are inserted between one liter reservoir and pulse tube. Design of the inertance tube pulse tube cryo-cooler is conducted by ARCOPTR program of NASA Ames Research Center. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature and refrigeration capacity according to the variations of inertance tube volume, reservoir volume and charging pressure are measured. and the cool down and load characteristics at the particular conditions are presented. As the representative results, no load temperature of the cold end is 52.7K and refrigeration capacity is 5W at 72K..

  • PDF

Design and Implementation of High Speed Pulse Motor Controller Chip (고속 펄스 모터 콘트롤러 칩의 설계 및 구현)

  • 김원호;이건오;원종백;박종식
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.7
    • /
    • pp.848-854
    • /
    • 1999
  • In this paper, we designed and implemented a precise pulse motor controller chip that generates the pulse needed to control step motor, DC servo and AC servo motors. This chip generates maximum pulse output rate of 5Mpps and has the quasi-S driving capability and speed and moving distance override capability during driving. We designed this chip with VHDL and executed a logic simulation and synthesis using Synopsys tool. The pre-layout simulation and post-layout simulation was executed by Compass tool. This chip was produced with 100 pins, PQFP package by 0.8${\mu}{\textrm}{m}$ gate array process and implemented by completely digital logic. We developed the test hardware board of performance and the CAMC(Computer Aided Motor Controller) Agent softwate to test the performance of the pulse motor controller chip produced. CAMC Agent enables user to set parameters needed to control motor with easy GUI(Graphic User Interface) environment and to display the output response of motor graphically.

  • PDF

Study for the Design and Measurement of the High Voltage Pulse Generator Using Transformers (트랜스포머를 이용한 고전압 펄스 발생 장치의 설계와 측정평가에 관한 연구)

  • Kim, Young-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2012
  • High-capacity high-voltage pulse generator that can be used for environmental clean-up was developed using transformers. High-voltage pulse is consists of the primary wave and the harmonic wave which are increased as a series circuit using transformers to make pulses. Each transformer has a band-pass characteristics. The output voltage of the pulse width 50[%] was decided. The output voltage of high-voltage pulse generator device was measured as 1.4[kV] (Peak-to-Peak).

Performance Test of 200-MW Pulse Transformer for 80-MW Klystron Load (80-MW 클라이스트론 부하용 200-MW 펄스 트랜스포머의 성능시험)

  • Jang, S.D.;Oh, J.S.;Son, Y.G.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2167-2169
    • /
    • 1999
  • A pulse transformer producing pulses with the peak power of 200-MW (400 kV 500 A at load side with $4.4{\mu}s$ flat-top) is required to drive the 80-MW pulsed klystron in the PLS linac. We have designed and manufactured the high power pulse transformer with 1 : 17 turn ratio. Its primary functions are to match the impedance of klystron tube to the modulators, and to provide step-up of the voltage. To obtain a fast rise time of the pulse voltage. Low leakage inductance and low distributed capacitance design is very important. In this paper, we discuss the equivalent circuit analysis of the pulse transformer, and present the full power performance test results of pulse transformer.

  • PDF

Bidirectional pulse generator made from pulse forming lines for linear induction accelerator (펄스형성선로로 구성된 선형유도가속기용 양방향 펄스 전원)

  • Park, Jeong-Ho;Kim, Jong-Hae;Ko, Kwang-Cheol;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1681-1683
    • /
    • 1997
  • Linear induction accelerator devised for high current beam accelerating is divided into two types. In the first type, a unidirectional pulse is injected to an accelerating gap and in the second type, a bidirectional pulse is injected. The purpose of this paper is design and manufacture of bidirectional pulse generator for linear induction accelerator, where the pulse width for acceleration is more than 50[nsee] and the designed maximum charging voltage is more than 200[kV].

  • PDF

A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis (맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구)

  • Lee, J.Y.;Lee, J.W.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

Design of compact phase controller for pulse tube refrigerator

  • Ki, Tae-Kyung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • A compact phase controller of pulse tube refrigerator is proposed in this paper. Most pulse tube refrigerators available now consist of a long inertance tube and reservoir as the phase controller. The long inertance tube and reservoir present a challenge for compact packaging in some applications. To overcome this disadvantage, the long inertance tube and reservoir are replaced with the compact phase controller consisted of mass, spring and damper in pulse tube refrigerator. This process is achieved using similarity of mechanical, electrical, and acoustic system and the specific configuration of the compact phase controller is designed. From the simulation code in this paper, the performance of pulse tube refrigerator with the designed compact phase controller is confirmed to be comparable to pulse tube refrigerator with the long inertance tube and reservoir.

The Comparison Experiment of Rotation Range of RC Servo Motors According to change of a Periods (주기변화에 따른 RC 서보모터 회전범위 비교실험)

  • Cha, Young-Youp
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1179-1182
    • /
    • 2011
  • RC servos are electro-mechanical devices that respond to a control signal, which instructs them to move their output shaft to a certain position. A servo is normally plugged into a radio receiver with a three pin connector. The three wires are a power (usually 4.8V to 6.0V), a ground, and a signal wire. The signal wire carries a PWM (Pulse-Width Modulation) signal consisting of a 1-2msec pulse repeated 50 times a second. A 1.5msec pulse will tell the servo to move to its output shaft to the center position, 0 degrees. For a servo with a 180 degree of motion, a 1msec pulse will move the servo to -90 degrees, and a 2msec pulse will move the servo to +90 degrees. In order to development a humanoid robot, mechanical design, fixtures design, analysis of kinematics, implementation moving program, selection of RC servo motor and controller are required. This study was performed to experimentally compare the rotation range of RC servo motors according to change of a periods.