• Title/Summary/Keyword: Pulse delay

검색결과 291건 처리시간 0.026초

Fabrication of dual mode ultrasonic transducers with PZT piezoelectric ceramics (PZT 압전 세라믹스를 사용한 2중 모우드 초음파 트랜스듀서 제작)

  • 김연보;노용래;남효덕
    • Electrical & Electronic Materials
    • /
    • 제8권5호
    • /
    • pp.572-579
    • /
    • 1995
  • Most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigate the mechanism of dual mode transducers that generate both of the longitudinal and shear waves simultaneously with single PZT element. The study is aimed to find the optimally desired cut by examining the anisotropic piezoelectric properties. Theory predicts that a mixed P/S mode transducer can be constructed using a rotated Z-cut of PZT piezoelectric ceramics. We study the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves as much as equally strong. The results are verified by the waveform in pulse-echo computer simulation and experiments. When the transducer is subjected to impedance analysis, it shows two thickness mode resonances, each of which being a mixed P/S thickness mode. By examining wave speeds on E transmitter delay line receiver setup, it is confirmed that the transducer can transmit and detect both longitudinal and shear wave simultaneously.

  • PDF

Time-resolved transient reflective image on silicon surface after single-shot fs-laser pulse irradiation (단일 펨토초 레이저펄스를 이용한 실리콘 표면에서의 시분해 반사율 측정 연구)

  • Moon, Heh-Young;Sidhu, Mehra Singh;Lee, Hyun-Kyu;Jeoung, Sae-Chae
    • Laser Solutions
    • /
    • 제14권4호
    • /
    • pp.21-27
    • /
    • 2011
  • In this work, we have studied on time-resolved transient reflective image of single crystalline Si surface after single-shot fs-laser irradiation with varying the laser fluence under two different laser spot sizes. The temporal profiles of transient reflectivity changes as well as its maximum values at the early delay time were found to be strongly dependent on both the laser beam spot size and laser fluence. We have interpreted the dependence of transient reflectivity changes on the laser spot size in terms of a relaxation of the generated free carriers to the bulk silicon, which should be interacted with the plasma.

  • PDF

Real Time Monitoring of Ionic Species Generated from Laser-Ablated Pb$(Zr_{0.52}Ti_{0.48})O_3$ Target Using Pulsed-Field Time-Of-Flight Mass spectrometer

  • 최영구;임훙선;정광우
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권8호
    • /
    • pp.830-835
    • /
    • 1998
  • The characteristics of the ablation plume generated by 532 nm Nd: YAG laser irradiation of a Pb(Zr0.52Ti0.48)O3 (PZT) target have been investigated using a pulsed-field time-of-flight mass spectrometer (TOFMS). The relative abundance of O+, Ti+, Zr+, Pb+, TiO+, and ZrO+ ions has been measured and discussed. TiO+ and ZrO+ ions were also found to be particularly stable within the laser ablation plasma with respect to PbO+ species. The behavior of the temporal distributions of each ionic species was studied as a function of the delay time between the laser shot and the ion extraction pulse. The most probable velocity of each ablated ion is estimated to be Vmp=1.1-1.6x 105 cm/s at a laser fluence of 1.2 J/cm2, which is typically employed for the thin film deposition of PZT. The TOF distribution of Ti+ and Zr+ ions shows a trimodal distribution with one fast and two slow velocity components. The fast velocity component (6.8x 10' cm/s) appears to consist of directly ablated species via nonthermal process. The second component, originated from the thermal evaporation process, has a characteristic velocity of 1.4-1.6 x 105 cm/s. The slowest component (1.2 x 105 cm/s) is composed of a dissociation product formed from the corresponding oxide ion.

Kinetic Study on the Low-lying Excited States of Ga Atoms in Ar

  • Kuntack Lee;Ju Seon Goo;Ja Kang Ku
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권8호
    • /
    • pp.663-669
    • /
    • 1994
  • Decay kinetics of Ga(5s), Ga(5p) and Ga(4d) atoms in Ar were studied by laser induced fluorescence technique. Theground state gallium atoms in the gas phase were generated by pulsed dc discharge of trimethyl gallium and argon mixtures. Both pulsed discharge and YAG-DYE laser system were controlled by a dual channel pulse generator and the delay time between the end of discharge and laser pulses was set 3.0-6.0 ms. The Ga(5s) and Ga(4d) atoms were generated by single photon excitation from the ground state Ga atoms and radiative lifetimes as well as the total quenching rate constants in Ar were obtained from the pressure dependence of the fluorescence decay rates. The Ga(5p) atoms were populated by a two-photon excitation method and the cascade fluorescence from Ga(5s) atoms were analyzed to extract quenching rate constant of Ga(5p) atoms by Ar in addition to radiative lifetimes of Ga(5p) state. The magnitudes of the quenching rate constants by Ar for the low-lying excited states of Ga atoms are 1.6-3$ {\times}10^{-11}cm^3$ molecul$e^{-1}s^{-1}$, which are much larger than those for alkali, alkaline earth and Group 12 metals. Based on the measured rate constants, kinetic simulations were done to assign state-to-state rate constants.

Assessment of the Purity of Emodin by Quantitative Nuclear Magnetic Resonance Spectroscopy and Mass Balance

  • Park, Sojung;Choi, Yu-Jin;Do, Giang Hoang;Seo, Eun Kyoung;Hyun, Seunghun;Lee, Dongho
    • Natural Product Sciences
    • /
    • 제25권3호
    • /
    • pp.222-227
    • /
    • 2019
  • Quantitative nuclear magnetic resonance (qNMR) is a well-established method adopted by international pharmacopoeia for quantitative and purity analyses. Emodin is a type of anthraquinone, well known as the main active component of Fabaceae, Polygonaceae and Rhamnaceae. Purity analysis of emodin is usually performed by using the high-performance liquid chromatography (HPLC)-UV method. However, it cannot detect impurities such as salts, volatile matter, and trace elements. Using the qNMR method, it is possible to determine the compound content as well as the nature of the impurities. Several experimental parameters were optimized for the quantification, such as relaxation delay, spectral width, number of scans, temperature, pulse width, and acquisition time. The method was validated, and the results of the qNMR method were compared with those obtained by the HPLC and mass balance analysis methods. The qNMR method is specific, rapid, simple, and therefore, a valuable and reliable method for the purity analysis of emodin.

Quench Analysis and Operational Characteristics of the Quench Detection System for the KSTAR PF Superconducting Coils (펄스전류 운전에 따른 KSTAR PF 초전도자석의 퀜치 분석 및 퀜치 검출 시스템 운전 특성)

  • Chu, Y.;Yonekawa, H.;Kim, Y.O.;Park, K.R.;Lee, H.J.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제11권3호
    • /
    • pp.20-25
    • /
    • 2009
  • The quench detection system of the KSTAR (Korea Superconducting Tokamak Advanced Research) primarily uses the resistive voltage measurement due to a quench. This method is to detect the resistive voltage generated by a quench, which is continuously maintained above the preset voltage threshold for a given holding time. As the KSTAR PF (Poloidal Field) coils are operated in the pulse current mode, the large inductive voltages are generated. Therefore the voltage threshold and the quench holding time should be determined by considering both the inductive voltages measured during the operation, and the maximum conductor temperature rise through the quench analysis. In this paper, the compensation methods for minimizing the inductive voltages are presented for the KSTAR PF coils. The quench hot spot analysis of the PF coils was carried out by the analytical and numerical methods for determining the proper values of the quench voltage threshold and the allowable quench protection delay time.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제52권12호
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

The Implementation of the Speed Measurement Board for the Reaction Wheel on the LEO Satellite using the T, M-Method (T-방식과 M-방식을 이용한 저궤도위성용 반작용 휠의 속도측정보드 설계)

  • Lee, Jae-Nyeung;Park, Sung-Hun;Heu, Su-Jin;Lee, Yun-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제40권9호
    • /
    • pp.827-832
    • /
    • 2012
  • In this paper, we will design the speed measurement board of LEO Satellite's reaction wheel which has two speed measuring methods as M-Method type and T-Method type. therefore we can use the advantage of two methods. and we will verify the availability of design on the on-board computer at the real LEO Satellite(KOMPSAT-3). In the reaction wheels satellite that can change the satellite's attitude is one of the leading drivers by the rotational inertia of the motor will perform attitude control. Reaction methods for detecting wheel rotation speed generated during a certain period T internal reaction wheel tacho pulse counting M-Method to detect wheel speed and wheel tacho pulses are generated by measuring the time between the detection rate can be divided into T-Method. M-method is simple to implement and benefit measurement time is constant, but slow fall in the velocity measurement accuracy is a disadvantage. In contrast, the time between tacho pulses to measure the T-Method to measure the precise speed at low speed and to measure the time delay is small, has the advantage. However, this method also in the actual implementation and the complexity of the operation at different speeds depending on the speed of operation has the disadvantage.