• 제목/요약/키워드: Pulse corona

검색결과 108건 처리시간 0.036초

NOx 제거용 저온 플라즈마 반응기에서의 플라즈마 화학 및 입자 성장 (The Plasma Chemistry and Particle Growth in the Low Temperature Plasma Reactor for removal of NOx)

  • 김동주;김교선
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.331-341
    • /
    • 1999
  • We analyzed theoretically the removal efficiency and the particle growth inside the pulse corona discharge reactor to remove $NO_x$ and investigated the effects of process variables such as the NO and $NH_3$ input concentrations. Most of NO is converted into $NO_2$ and $HNO_3$ and the $HNO_3$ reacts with $NH_3$ to form the $NH_4NO_3$ particles. About 6.4% of NO is converted into $HNO_2$ which form the $NH_4NO_2$ particles by reaction with $NH_3$. Some of $NO_2$ follows the reaction pathway to form $NO_3$ and $N_2O_5$. The amount of particles formed inside the reactor is basically determined by the input $NH_3$ concentration. The ratio of NO to $NH_3$ affects the reactor length for particle formation significantly. The higher the input concentrations of NO and $NH_3$ are, the faster the particles grow.

  • PDF

디젤엔진의 후처리장치로서 PCD 플라즈마 시스템에 관한 연구 (A Study on the PCD Plasma System as an After Treatment Apparatus in Diesel Engine)

  • 유경현
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.70-77
    • /
    • 2012
  • The selective catalytic reduction(SCR) system used to reduce NOx in diesel engines requires an NO/$NO_2$ ratio of about 1 in exhaust emissions to realize the fast SCR mode at temperatures lower than $300^{\circ}C$. This study investigated the characteristics of a plasma system as a pre-active apparatus for the fast SCR reaction mode of an SCR system. Plasma was generated by the pulse corona discharge(PCD) method with a four-channel wire-cylinder reactor. This study showed that plasma was easily generated in the exhaust gas by the PCD system, and the peak voltage of the normal state condition for plasma generation was generally 12 kV. The PCD system easily converted NO into $NO_2$ at lower temperatures and the NO/$NO_2$ conversion ratio increased with the discharge current for plasma generation. But the PCD system could not convert NO into $NO_2$ at higher engine speeds and higher engine loads due to the lack of oxygen in exhaust gas. The PCD system also activated the diesel oxidation catalysts(DOC) system to reduce CO emissions.

바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (1) (A Study on Improvement of the Performance of Pulsed AC Ion Bar (1))

  • 이동훈;최동수;정용철;김상민
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.34-38
    • /
    • 2014
  • In Display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods since the ionizer can create balanced ion that is delivered to producing goods to minimize electrical damages when manufacturing. However, the most general type of ionization is called, "Corona Discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. In this research, our objective to resolve the current issue via applying "Coupling Condenser" on each counter electrodes of Corona discharging type ionizer. The result is that the ion balance was maintained the satisfied range that is within +/-100V when we changed the duty ratio of the High Voltage of Pulse AC about 40 ~ 70%. In addition, when levelling the High Voltage of Pulse AC, the ion balance holds the range within +20 ~ 0V. Even though we have tested the same experiment for a year, we have seen the range changes roughly ${\pm}50V$.

임펄스전압에 의한 침 대 평판전극에서 수중방전특성 (Discharge Characteristics between Needle and Plane Electrodes in Water under Impulse Voltages)

  • 최종혁;박건훈;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.67-74
    • /
    • 2008
  • 이 논문은 수중의 침 대 평판 전극에서 임펄스전안의 크기와 극성, 물의 저항률 등과 같은 다양한 조건에 따른 방전특성을 나타낸다. 스트리머코로나가 침전극 끝단에서 발생하며 평판전극을 향하여 진전하여 최종적으로 전극 사이가 섬락에 이르게 된다. 동일한 전압에서 물의 저항률이 작을 때 스트리머코로나의 분기로는 물의 저항률이 클때 보다 더욱 굵고 밝게 나타났다. 정극성에 비해서 부각성 스트리머코로나가 더욱 많은 분기로를 형성하며 더욱 넓게 퍼지는 것으로 나타났다. 스트리머코로나의 개시 후 방전의 진전과 더불어 수 백 [mA]에서 수 [A]에 이르는 많은 수의 전류펄스가 발생하였다. 정극성의 절연파괴까지의 지연시간은 부극성에 비하여 매우 짧았으며, 전극에 공급되는 전구방전에너지는 물의 저항률에 반비례하였다.

가포화 자기스위치를 이용한 탈황탈질 시스템의 전원장치에 관한 연구 (A study on topology of the DeNOx, DeSOx using magnetic pulse compressors)

  • 김수홍;이용덕;김승모;김병섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.157-159
    • /
    • 2008
  • Generally, Capacitor charging power supply (CCPS) consist of the full-bridge inverter, LC resonant tank and capacitance load. The multi-connection systems are normally used for high voltage or high power application. In this paper, conventional parallel operation resonant type and proposed series operation PWM type CCPS for pulse corona occurrence of DeSOx, DeNOx system using magnetic pulse compressor make a comparison. The effect of proposed CCPS is verified by circuit characteristics analysis of parallel operation resonant type and series operation PWM type, and it is confirmed by simulation result.

  • PDF

저온 플라즈마 장치에서 $C_2H_4$의 첨가량이 NOx 저감에 미치는 영향에 대한 실험적 연구 (An Experimental Study on Effect of Adding $C_2H_4$ for Reduction of NOX using Low Temperature Plasma Apparatus)

  • 권준호;강우정;정태용
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.211-218
    • /
    • 1998
  • The purpose of this study is to investigate the reduction rate of NOX according to several parameters(NOX concentration, the flow rate of gas, the additional amount of C2H4, input voltage, input frequency and so in) when NOX is reduced by using PPCP(Pulse-induced Plasma Chemical Process). PPCP is based on the plasma-chemical technology, which induces narrow voltage pulses to binary electrode structure.

  • PDF

배기가스 처리용 양방향 펄스 전원 (Bidirectional pulse generator for removal of flue gas)

  • 박정호;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.233-236
    • /
    • 1997
  • An investigation has been made of the various plasma chemistry reactions that occur in the corona discharge of an electrostatic precipitator operating in a typical flue gas. As the results of investigation, sulphur dioxide is removed principally by reactions with OH radicals to produce sulphuric acid, while nitrogen oxides are removed principally by reduction via the N radical to molecular nitrogen. If electrostatic precipitator\ulcorner used for flue gases are operated with positive voltages instead of negative dc voltages, there are significant reductions in the emission of the undesirable gases SO$_2$, NO, and NO$_2$. Thus, in this paper we design the bidirectional pulse generator for removal of flue gas, where the pulse width is more than 50[nsec] and the maximum output voltage is more than 100[kVl.

  • PDF

펄스전원을 이용한 수중플라즈마 방전에 관한 연구 (A Study on ther Water Plasma Chemical Process Discharge by Pulse Power Supply)

  • 신완호;홍원석;유효열;박선순;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2179-2181
    • /
    • 2005
  • An experimental study on the water plasma characteristics of removal efficiency for organic contaminants in dye waste water has been investigated. In this study, dielectric barrier discharging electrodes with round shape have disposed cross each other in reactor, and pulse power was supplied to between each electrodes. Its output pulse voltage range is from 0[V] to 30[kV] and output frequency range is from 100[Hz] to 2[kHz]. Using proposed system, High frequency discharge is tested in the mixed Tone(air and water) and the space distribution of streamer corona plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발 (Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process)

  • 유정석;백민수;김태희;김정일;김유석;최석호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF