• Title/Summary/Keyword: Pulse analysis system

Search Result 649, Processing Time 0.025 seconds

Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method (단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성)

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • This paper investigates operating characteristics of three-phase matrix converter with unity input power factor by direct duty-ratio pulse-width modulation in the case of balanced and unbalanced load. It can be found from the system analysis that (1) The control algorithm for unity power factor is not related to the variables of load sides but the input voltages, (2) With the balanced three-phase load except for the pure reactive load, the unity input power factor can be achieved, (3) In the case of the unbalanced linear load, the equivalent input characteristics of the matrix converter can be seen like the nonlinear resister, (4) When the input frequency and the output frequency have the specific relationship, each input phases have the same sharing of the average power. The feasibility and validity of the analysis were verified by simulation and experimental results.

Survey for Needs of Bio-Signal Devices for the Diagnosis, Assessment, or Analysis of Neurocognitive Disorder in Korean Society of Oriental Neuropsychiatry (인지 장애 진단·평가·분석을 위한 생체신호 장비 개발에 대한 수요조사: 한방신경정신과학회 회원들을 대상으로)

  • Choi, Yujin;Kim, Ji Hye;Kim, Kahye;Kim, Jaeuk
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.2
    • /
    • pp.89-99
    • /
    • 2020
  • Objectives: The purpose of this study was to identify the needs of bio-signal devices for the diagnosis, assessment, and analysis of neurocognitive disorder in Korean medicine (KM) hospitals and clinics. Methods: A questionnaire was developed to survey the current status of medical device use, and diagnosis and interventions for patients with cognitive disorders in KM hospitals and clinics. November 11~December 2, 2019, 114 responses (71.9% completed) were collected by internet-based questionnaires from the members of the Korean society of Oriental Neuropsychiatry. Results: The clinical requests were in the descending order of hematology analyzer, ultrasound imaging system, and electroencephalography among the 15 most commonly used devices of which research would support for their clinical usability. The biosignal-based devices showed the highest research demands for patients with mild cognitive impairment rather than more severe stages of cognitive impairment. Prevention rather than diagnosis, or several treatment regimens was the strongest clinical area of the KM for patients with neurodegenerative cognitive impairment. Many responded that five to 10 minutes of test duration and 20,000 won to 30,000 won of cost would be appropriated for a new device to be developed. Conclusions: There were strong demands for the development of bio-signal devices for neurocognitive disorders among the KM doctors. Specifically, it showed high needs for the technology that can be used in the prevention area of cognitive disorders. Additionally, new medical devices to assess cognitive functions and to obtain KM pattern-related information were the high needs.

Heart Rate Variability in Kiwooljeung with the Age Group between Twenties and Thirties (기울증(氣鬱症)으로 진단된 2-30대 환자의 심박변동 분석)

  • Kim, Bo-Young;Lee, Seung-Hee;Kwen, Soon-Ju;Chung, Dae-Kyoo;Kwak, Min-Ah;Lee, Ji-In
    • Journal of Oriental Neuropsychiatry
    • /
    • v.14 no.2
    • /
    • pp.135-143
    • /
    • 2003
  • Objectives : The purpose of this study is to analyze and compare heart rate variability(HRV) of patient of twenties and thirties diagnosed as Kiwooljeung with healthy controls'. Methods : We measured HRV of 35 patient(20 to 39 years old, male 14, female 11) diagnosed as Kiwooljeung and 40 healthy controls(male 24, female 16). HRV was measured by SA-3000P(Medicore, Korea) for 5 minutes after 5 minutes resting. Results : 1. In time domain analysis, Mean pulse rate(PRT) in Kiwooljeung group was higher than healthy controls. Standard deviation of all normal N-N intervals (SDNN) in Kiwooljeung group was lower and the results of twenties and thirties were same. 2. In frequency domain analysis, total power(TP), very low frequency(VLF), low frequency(LF), high frequency(HF), Ln TP, Ln VLF, Ln LF, Ln HF in Kiwooljeung group were lower than healthy controls but LF/HF ratio was higher than healthy controls. 3. Comparing gender in Kiwooljeung group, LF/HF ratio in male was higher than female. Conclusions : This study suggests lower activity and imbalance of cardiac autonomous nervous system in Kiwooljeung with the age group between twenties and thirties.

  • PDF

System Design and Performance Analysis of a Variable Frequency LED Light System for Plant Factory

  • Han, Jae Woong;Kang, Tae Hwan;Lee, Seong Ki;Han, Chung Su;Kim, Woong
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.87-95
    • /
    • 2014
  • Purpose: The purpose of this study was to design a variable frequency LED light system for plant factory which combined red, blue, green, white, and UV lights and controlled the ratio of the light wavelength. In addition, this study evaluated the performance of each combination of LED to verify the applicability. Methods: Four combinations of LED (i.e. Red+Blue, Red+Blue+Green, Red+Blue+White, Red+Blue+UV) were designed using five types of LED. The system was designed to control the duty ratio of each wavelength of LED by 1% interval from 0~100%, the pulse by 1Hz interval from 1~20kHz. Response characteristics of the control system, spectral distribution of each combination, light uniformity and uniformity ratio were measured to test the performance of the system. Results: Clean waveforms were measured from 10Hz to 10kHz regardless of duty ratio. Frequency distortion was observed within 5% of inflection point at frequencies above 10kHz regardless of duty ratio, but it was judged negligible. Spectra showed a normal distribution, and maximum PPF with duty ratio of 100% was $271.4{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for the Red+Blue combination. PPF of the Red+Blue+Green combination was $258.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and that of the Red+Blue+White combination was $273.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. PPF of the Red+Blue+UV combination was $267.7{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Uniformity ratio for the area excepting border showed 0.90 for the Red+Blue and Red+Blue+White combinations, 0.87 for the Red+Blue+Green combination, and 0.88 for the Red+Blue+UV combination. The light was irradiated evenly at the area excepting border, so it was suitable for plant growing. Conclusions: From the results of this study, response characteristics of the control system, spectral distribution of each combination, light uniformity and uniformity ratio were suitable for applying into the plant factory.

Power-efficiency Analysis of the MIMO-VLC System considering Dimming Control (조광제어를 고려한 MIMO-VLC 시스템의 전력 효율 분석)

  • Kim, Yong-Won;Lee, Byung-Jin;Lee, Byung-Hoon;Lee, Min-Jung;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.169-180
    • /
    • 2018
  • White light-emitting diodes (LEDs) are more economical than fluorescent lights, and provide high brightness, a high lifetime expectancy, and greater durability. As LEDs are closely connected with people's daily lives, dimming control of LED is an important component in providing energy savings and improving quality of life. In visible light communications systems using these LEDs, multiple input multiple output (MIMO) technology has attracted a lot of attention, in that it can attain the channel capacity in proportion to the number of antennas. This paper analyzes the power performance of three kinds of modulation in visible light communications (VLC) systems applied space-time block code (STBC) techniques. The modulation schemes are return-to-zero on-off keying (RZ-OOK), variable pulse position modulation (VPPM), and overlapping pulse position modulation (OPPM), and dimming control was applied. The power requirements and power consumption were used as metrics to compare the power efficiency in $2{\times}2$ STBC-VLC environments under the three kinds of modulation. We confirm that dimming control affects the communications performance of each modulation scheme. VPPM showed greater consumption among the three modulations, and OPPM showed energy savings comparable to VPPM.

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

Responses of Health Physical Fitness and Arterial Stiffness through Cigarette Smoking (흡연습관이 성인 남성의 건강관련체력 및 동맥경직도에 미치는 영향)

  • Jung, Min-Kyung;Park, Eun-Kyung;Yoo, Jae-Hyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.2
    • /
    • pp.197-205
    • /
    • 2019
  • This study was to compare arterial stiffness and hemodynamic responses between male smokers and non-smokers. This study also investigates the influences of smoking before exercise on arterial stiffness and hemodynamic responses. 24 male subjects of age 20-29 without history of cardiorespiratory disease were divided into smokers and non-smokers. Smokers had more than 5 years of smoking experience. In order to evaluate the effects of pre-exercise smoking, smokers were tested twice, once with a cigarette before the exercise and the other once without one. Data was collected from bio-impedance analysis, SphygmoCor XCEL, graded exercise test, and fitness test. Main results of this study are as follows: First, there are differences between smokers and non-smokers in cardiorespiratory and hemodynamic response functions, as shown by maximal oxygen consumption, exercise duration, and heart rate. Second, the although the arterial stiffness between smokers and non-smokers showed statistically significant differences in the speed of the pulse wave velocity and augmentation index, smoker had a faster rate. It shows that smoking behavior has a negative impact on the cardiovascular system. Third, pre-exercise smoking behavior does have an impact on cardiorespiratory and hemodynamic response functions, as shown by exercise duration and heart rate. Lastly, arterial stiffness between smokers and non-smokers showed statistically not significant in the speed of the pulse wave velocity and augmentation index. However, the difference was not statistically significant. Brachial systolic pressure, a component of pulse wave analysis, on the other hand, was significantly dependent on pre-exercise smoking behavior. Subjects who participated in this study are college students in early 20s. Given their relatively short history of smoking, it is possible that their smoking habits are not severe enough to develop into cardiorespiratory or cardiovascular diseases. But Smokers showed lower levels of cardiopulmonary functions, as maximal oxygen consumption and exercise duration than nonsmokers.

Performance Analysis of an Optical CDMA System for multi-user Environment (다중 사용자 환경에서의 광 CDMA 시스템 성능 분석)

  • 전상영;김영일;이주희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1134-1141
    • /
    • 1999
  • In this paper, we implement an optical code division multiple access(OCDMA) system and analyze the performance of the implemented system. In the implemented system, a transmitter encodes input data into optical pulses by using laser diode, and spreads the encoded pulses in an encoder which consists of 4 stage delay lines. The decoder which is the same structure as that of encoder delays and combines the spreaded pulses, and thus recovers the original data. At first, we discuss the auto- and cross-correlations of OCDMA signals under both environments of single user and multi-users, and then verify the simulation results with experimental results. We also evaluate the effect of a number of stages of delay line and code length on the system performance through computer simulations. As experimental results we can see that if the decoder have the same configuration as that of encoder, the peak auto-correlation characteristics can be achieved, and thus we can recover the original data from received data. As simulation results we can see that although bit error rate decreases as code length decreases or the number of stage of delay line increases, it is difficult to implement the system because the pulse width becomes narrow. From the results, we can apply CDMA technologies to optical communication networks.

  • PDF

New Drug Delivery System Based on a Laser-Induced Shockwave (레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발)

  • Han, Tae-Hee;Lee, Hyun-Hee;Gojani, Ardian B.;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Impingement of a high power laser pulse (above 1 GW/$cm^2$) on a metal foil causes its ablation, which is characterized by a rapid expulsion of matter and the initiation of a strong shock wave inside the solid metal. The shock propagates through the foil and reverberates on the rear side, causing its deformation and microparticle ejection, which were deposited on the foil prior to ablation. Based on this principle, we are developing a new drug delivery system - Biolistic gun. Current study is focused on the controllability, stability, efficiency of the system, and characterization of the penetration shapes in various conditions. We have tested the system by applying direct and confined ablation. Several different media combinations were used for confinement-BK7 glass, water, BK7 glass with water, and succulent jelly(ultrasono jelly, RHAPAPHRM). Biological tissue was replicated by a 3% gelatin solution. Present data shows that the confinement results in enhancement of penetration shape reached by 5 um cobalt microparticles. Based on the analysis of the experimental results we observe that the penetration shape of microparticles can be controlled by adjusting the thickness of confinement media.

Space Debris Tracking Coverage Analysis of Spinning Disk for Optical Path Switch of Geochang Laser Tracking System (거창 레이저 추적 시스템의 광 경로 전환을 위한 회전 디스크의 우주쓰레기 레이저 추적 성능 분석)

  • Sung, Ki-Pyoung;Lim, Hyung-Chul;Yu, Sung-Yeol;Choi, Man-Soo;Ryou, Jae-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.391-399
    • /
    • 2020
  • KASI (Korea Astronomy and Space Science Institute) has been developing the multipurpose laser tracking system with three functions of satellite laser tracking, adaptive optics and space debris laser tracking for scientific research and national space missions. The space debris laser tracking system provides the distance to space debris without a laser retro-reflector array by using a high power pulse laser, which employs a spinning disk to change the optical path between the transmit and receive beams. The spinning disk causes the collision band which is unable to reflect the returned signal to a detector and then has an effect on the tracking coverage of space debris. This study proposed the mathematical model for tracking coverage by taking into account the various specifications of spinning disk such as disk size, spinning velocity and collision rate between the disk and hole. In addition, the spinning disk specifications were analyzed in terms of tracking coverage and collision band based on the mathematical model to investigate tracking requirements of the Geochang laser tracking system.