• Title/Summary/Keyword: Pulse analysis system

Search Result 650, Processing Time 0.032 seconds

Performance Analysis of UWB Systems in the Presence of Timing Jitter

  • Guvenc, Ismail;Arslan, Huseyin
    • Journal of Communications and Networks
    • /
    • v.6 no.2
    • /
    • pp.182-191
    • /
    • 2004
  • In this paper, performances of different ultra-wideband (UWB) modulation schemes in the presence of timing jitter are evaluated and compared. Static and Rayleigh fading channels are considered. For fading channels, Oat and dispersive channels are assumed. First, bit error rate (BER) performances for each case are derived for a fixed value of timing jitter. Later, a uniform distribution of jitter is assumed to evaluate the performance of the system, and the theoretical results are verified by computer simulations. Finger estimation error is treated as timing jitter and an appropriate model is generated. Furthermore, a worst case distribution that provides an upper bound on the system performance is presented and compared with other distributions. Effects of timing jitter on systems employing different pulse shapes are analyzed to show the dependency of UWB performance on pulse shape. Although our analysis assumes uniform timing jitter, our framework can be used to evaluate the BER performance for any given probability distribution function of the jitter.

Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis (맥진기술동향 조사를 통한 맥진기 개발방안 제안)

  • Lee, Yu-Jung;Lee, Jean;Kim, Jang-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.174-179
    • /
    • 2009
  • Arterial pulse palpation is an important diagnostic method in Oriental Medicine, particularly for obtaining information about a patient's health conditions or illness, or for confirming a diagnostic conclusion based on the patient's pulsation. The pulse analyzer is both a leading Oriental Medical equipment and a promising tool with such a strong industrial ripple effect that it was selected as one of the four strategic tools for world Oriental Medical instrument market domination at a recent survey. Although various pulse analyzers had been developed, however, most of these were not widely used for clinical diagnosis, due perhaps to lack of the appliance's reliability caused by its inability to reflect the requirements of the clinicians. Thus, in this thesis, the clinical requirements for the pulse analyzer were identified and analyzed by conducting a questionnaire survey among Oriental Medicine clinicians. By looking into the basic functions of a pulse analyzer, the required measurement time, and the medical insurance fee required were determined and among others, the appliance's specific requirements were determined. Moreover, by investigating on the latest patent trend, the technical elements that are needed for the development of a next-generation pulse analyzer were identified. Through these processes, the flow of the technology that must be developed for the pulse analyzer was determined, and the direction for the development of the specific pulse analyzer hardware, sensor, and diagnostic algorithm was identified and proposed.

Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device (영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석)

  • Kim, Dong-Young;Lee, Sang-Suk;Hyeon, Seog-San;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.146-151
    • /
    • 2014
  • The pulse waveforms of a carotid artery in the neck and a radial artery in the hand wrist were individually measured by using clip-type pulsimeter equipped with a permanent and Hall device. The pulse transit time and the pulse wave velocity obtained through comparison of two pulse waveforms were analyzed each other. A value of the pulse wave velocity was about 8.5 m/s similar to one measured by a conservative method. This result suggests that the clip-type pulsimeter as the reproducible and reliable one oriental diagnostic medical device can be predicted to any atherosclerosis state in the cardiac circulatory system.

Analytical Study of Position Control Characteristics of the Variable Reluctance Pulse motor (펄스전동기의 위치제어특성에 관한 해석적 연구)

  • 이윤종;장세훈;이용범
    • 전기의세계
    • /
    • v.28 no.1
    • /
    • pp.59-66
    • /
    • 1979
  • The linearized models on per for mance dynamics of the pulse motor have been already proposed by many others. These models exhibit certain advantages of their own because of their simple formulation, but in many cases the models are proved to be inadequate for further accurate analysis of the motor dynamics, owing to impractical and rather rough assumptions in the derivation. In this study a dynamic state transition model is induced, using the equivalent circuit obtained from the operating principle of the variable reluctance pulse motor which turns out to be nonlinear equation. This nonlinear dynamic state equation is numerically analysed by the use of UNIVAC System/3(OS/3) digital computer at hand. In the course of the dynamic analysis of the performance characteristics of a testing motor, dependance of the inertia of rotor and load, the coefficient of viscous friction between rotor and housing, and the winding resistance of the stator is discussed and a comparative study of the machine constants is carried on as related to the design problem of the motor.

  • PDF

Hybrid Sinusoidal-Pulse Charging Method for the Li-Ion Batteries in Electric Vehicle Applications Based on AC Impedance Analysis

  • Hu, Sideng;Liang, Zipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.268-276
    • /
    • 2016
  • A hybrid sinusoidal-pulse current (HSPC) charging method for the Li-ion batteries in electric vehicle applications is proposed in this paper. The HSPC charging method is based on the Li-ion battery ac-impedance spectrum analysis, while taking into account the high power requirement and system integration. The proposed HSPC method overcomes the power limitation in the sinusoidal ripple current (SRC) charging method. The charger shares the power devices in the motor inverter for hardware cost saving. Phase shifting in multiple pulse currents is employed to generate a high frequency multilevel charging current. Simulation and experimental results show that the proposed HSPC method improves the charger efficiency related to the hardware and the battery energy transfer efficiency.

Analysis of Relations Between Physiologic Parameters and Pulse Transit Time on the Ultrasound Therapy (초음파 재활치료 시 PTT와 생리변수의 상관관계 분석)

  • Kim, Sung-Min;Choi, Sang-Hyuk;Lee, Man-Pyo;Choi, Byeong-Cheol;Jung, Whoi-Seong;Park, Sung-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1514-1520
    • /
    • 2007
  • Currently, the signal of the human body is measured with various methods, and a noninvasive investigation of various methods is useful diagnosis method. PTT(Pulse Transit Time) which is noninvasive investigation make use of to estimate the physiological phenomena. PTT has a latent information of cardiovascular system. So we have the experiments for analysis of the relations between PTT and physiological parameters. We examine to correlate to the physiological parameters, an age and degree of paralysis on the ultrasound therapy. The 40 patients who has a such paralysis join our experiment, and we obtain the PTT data that normal condition and states after ultrasound therapy. We study that PTT after the ultrasound therapy for patients who have a paralysis was related to an age and degree of paralysis.

Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter (충격기류식 여과집진장치에서 압력손실에 영향을 주는 인자의 효율예측)

  • Suh, Jeong-Min;Ryu, Jae-Yong;Lim, Woo-Taik;Jung, Moon-Sub;Park, Jeong-Ho;Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.437-446
    • /
    • 2010
  • The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 m2 filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.

Analysis on the Power Spectrum of Direct Sequence-Time Hopping UltraWideBand System (DS-TH UWB 시스템의 전력 스펙트럼 분석)

  • Kim Young-Chul;Lee Jeong-suk;Kang Duk-Keun
    • Journal of Digital Contents Society
    • /
    • v.5 no.3
    • /
    • pp.219-224
    • /
    • 2004
  • In This paper, we have analyzed the power spectrum of DS-TH Ulhawideband (Direct Sequence-Time Hopping UWB) system which used pseudo-noise (PN) code. The DS-TH UWB system proposed in this paper multiplies the information signal with PN code to construct pulse train with random pattern and then the chips in pulse train are bundled into several groups to map to the particular value. The (+)/(-) pulse is tented in the time slot of frame by comparing a particular value with timing information that was stored in the lookup table. Thus, the energy spark (Comb Line) which is generated certainly in convantional system can be suppressed efficiently by PN code. And we knew that the proposed DS-TH UWB System even could have very smoothing power spectrum ctaracteristic without applying high speed Time-Hopping code.

  • PDF

Classification of Emotional States of Interest and Neutral Using Features from Pulse Wave Signal

  • Phongsuphap, Sukanya;Sopharak, Akara
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.682-685
    • /
    • 2004
  • This paper investigated a method for classifying emotional states by using pulse wave signal. It focused on finding effective features for emotional state classification. The emptional states considered here consisted of interest and neutral. Classification experiments utilized 65 and 60 samples of interest and neutral states respectively. We have investigated 19 features derived from pulse wave signals by using both time domain and frequency domain analysis methods with 2 classifiers of minimum distance (normalized Euclidean distanece) and ${\kappa}$-Nearest Neighbour. The Leave-one-out cross validation was used as an evaluation mehtod. Based on experimental results, the most efficient features were a combination of 4 features consisting of (i) the mean of the first differences of the smoothed pulse rate time series signal, (ii) the mean of absolute values of the second differences of thel normalized interbeat intervals, (iii) the root mean square successive difference, and (iv) the power in high frequency range in normalized unit, which provided 80.8% average accuracy with ${\kappa}$-Nearest Neighbour classifier.

  • PDF

Comparative study of pulse point using hemodynamics (혈류역학을 이용한 촌구와 인영의 특성비교)

  • Shin, Sang-hoon;Park, Dae-hun;Park, Young-jae;Park, Young-bae
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.241-248
    • /
    • 2004
  • Objectives : The purpose of this study is to examine the hemodynamic characteristics of pulse point. Methods : The computational analysis algorithms of arterial tree system was derived. In order to investigate the effect of internal organ on the pulse point, the diameter of celiac artery was reduced by half. Results : The sensitivity of flow change at the Inyoung(Renying) is better than that of the Chongu(Cunkou). but the Inyoung was worse than the Chongu in the point of the left and right symmetry. The pressure changes at the Inyoung and the Chongu were in the similar range. Conclusions : It was found from the result that the Chongu shows the more symmetrical hemodynamic characteristics than the Inyoung.

  • PDF