• Title/Summary/Keyword: Pulse Width

Search Result 1,788, Processing Time 0.211 seconds

Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis - (맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 -)

  • Kim, Gyeong-Cheal;Lee, Jeong-Won;Ryu, Kyeong-Ho;Park, Dong-Il;Shin, Woo-Jin;Kang, Hee-Jung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.

Design of Solid-State Transmitter and Receiver for Active Array Radar System (능동 배열 레이더 시스템 구현을 위한 반도체형 송수신기 설계)

  • Lee, Yu-Ri;Kim, Jong-Pil;Lee, Soo-Ho;Jeong, Myung-Deuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1335-1342
    • /
    • 2010
  • This paper presents design and measurement result of S-band, $\bigcirc$ kW solid-state transmitter and receiver for active array radar system. Transmitter characteristics show 63 dB gain, 200 usec pulse width(max.), 10 % duty(max.) and 63 dB pulse to pulse stability. Receiver characteristics show 23 dB gain and 3.2 dB noise figure. Receiving mode for pulse network analyzer is used for pulse to pulse stability measurement. Measurement results satisfies all specification.

A Study on Poly-pulse Pair Estimation Method for Reduction of Bias Errors in a Weather Radar (기상레이다에서의 편향오차 감소를 위한 다중 펄스페어 추정기법에 관한 연구)

  • 이종길
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12B
    • /
    • pp.2292-2297
    • /
    • 1999
  • Some observed weather spectra show that nearly 25% of weather spectra are seriously skewed and can not be considered to be symmetric. However, the conventional pulse pair method was derived and has been evaluated under the assumption that the weather spectrum is symmetric and narrow. This means that the conventional pulse pair method may need reevaluation. Therefore, this paper analyzed the bias errors of pulse pair estimates in the skewed spectra. The bias errors of pulse pair mean estimates are more serious comparing with the pulse pair width estimates. In this paper, the poly-pulse pair method is suggested to reduce these bias errors of mean estimates. It was shown that the mean bias errors can be reduced remarkably using the newly suggested poly-pulse pair method.

  • PDF

Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor (어레이 압저항 센서를 활용한 체질맥 임상연구)

  • Lee, Si-Woo;Joo, Jong-Cheon;Kim, Kyung-Yo;Kim, Jong-Yeol
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.1
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

High Power Microwave Resonant Ring (고출력 마이크로파 Resonant Ring)

  • Park, S.S.;Park, S.W.;Kim, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1275-1277
    • /
    • 1995
  • We designed and constructed an extremly high power s-band traveling wave resonator for the test of high power microwave components using 80MW pulsed klystron with $4{\mu}s$ pulse width. The 10dB directional coupler for the input power coupling was used, and the ring consists of phase shifter, tuner, H-band, and other microwave components. The designed total electrical length of the system is 10 times of the waveguide wavelength, ${\lambda}_g$=15.3cm, and the measured total insertion loss is 0.15dB. The low power test measurment showed the power multiplication of 14.69. The design goal is to achieve the peak power of 300MW, pulse width $4{\mu}s$ with 30 pulse repetition rate. In this article we discuss the treveling wave resonant ring constructed at the PAL laboratory together with the test results.

  • PDF

Design and fabrication on 2.7-2.9 GHz, 1.5 kW pulsed Solid state power amplifier (1.5 kW, 2.7-2.9 GHz, 반도체 펄스 전력 증폭기 설계 및 제작)

  • Jang, S.M.;Choi, G.W.;Joo, J.H.;Choi, J.J.;Park, D.M.
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.91-96
    • /
    • 2005
  • In this paper, describes the design and performance of a 1.5 kW solid-state pulsed power amplifier, operating over 2.7-2.9 GHz at a duty of 10% and with a pulse width of 100 us for radar application. The solid-state pulsed power amplifier configures a series of 8-stage cascaded power amplifier with different RF output power levels. Low loss Wilkinson combiners are used to combine output powers of six 300W high power solid state modules. Tests show peak output power of 1.61 kW, corresponding to PAE of 26.2% over 2.7-2.9 GHz with pulse width of 100 us and a PRF of 1 kHz.

  • PDF

Natural Balancing of the Neutral Point Potential of a Three-Level Inverter with Improved Firefly Algorithm

  • Gnanasundari, M.;Rajaram, M.;Balaraman, Sujatha
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1306-1315
    • /
    • 2016
  • Modern power systems driven by high-power converters have become inevitable in view of the ever increasing demand for electric power. The total power loss can be reduced by limiting the switching losses in such power converters; increased power efficiency can thus be achieved. A reduced switching frequency that is less than a few hundreds of hertz is applied to power converters that produce output waveforms with high distortion. Selective harmonic elimination pulse width modulation (SHEPWM) is an optimized low switching frequency pulse width modulation method that is based on offline estimation. This method can pre-program the harmonic profile of the output waveform over a range of modulation indices to eliminate low-order harmonics. In this paper, a SHEPWM scheme for three-phase three-leg neutral point clamped inverter is proposed. Aside from eliminating the selected harmonics, the DC capacitor voltages at the DC bus are also balanced because of the symmetrical pulse pattern over a quarter cycle of the period. The technique utilized in the estimation of switching angles involves the firefly algorithm (FA). Compared with other techniques, FA is more robust and entails less computation time. Simulation in the MATLAB/SIMULINK environment and experimental verification in the very large scale integration platform with Spartan 6A DSP are performed to prove the validity of the proposed technique.

OPTIMIZATION OF OPERATION PARAMETERS OF 80-KEV ELECTRON GUN

  • Kim, Jeong Dong;Lee, Yongdeok;Kang, Heung Sik
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.387-394
    • /
    • 2014
  • A Slowing Down Time Spectrometer (SDTS) system is a highly efficient technique for isotopic nuclear material content analysis. SDTS technology has been used to analyze spent nuclear fuel and the pyro-processing of spent fuel. SDTS requires an external neutron source to induce the isotopic fissile fission. A high intensity neutron source is required to ensure a high for a good fissile fission. The electron linear accelerator system was selected to generate proper source neutrons efficiently. As a first step, the electron generator of an 80-keV electron gun was manufactured. In order to produce the high beam power from electron linear accelerator, a proper beam current is required form the electron generator. In this study, the beam current was measured by evaluating the performance of the electron generator. The beam current was determined by five parameters: high voltage at the electron gun, cathode voltage, pulse width, pulse amplitude, and bias voltage at the grid. From the experimental results under optimal conditions, the high voltage was determined to be 80 kV, the pulse width was 500 ns, and the cathode voltage was from 4.2 V to 4.6 V. The beam current was measured as 1.9 A at maximum. These results satisfy the beam current required for the operation of an electron linear accelerator.

A Study on Hair Removal Characteristics Using a Long-pulsed Alexandrite Laser

  • Choi Jin-Young;Kim Sang-Gil;Park Jong-Woong;Park Sung-Joon;Kim Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Recently, lasers have become widely used throughout the medical treatment field. Several types of lasers have been used for the purpose of hair removal since the Alexandrite laser was approved by the FDA (Food & Drug Administration) for clinical epilation. In this study, a long-pulsed Alexandrite laser system for hair removal adopting a multi-discharge method in which three flash lamps are turned on consecutively was designed and fabricated. This laser system shows the technology that makes it possible to create extended pulse by turning on three flash lamps consecutively. With this technique, the pulse width can be varied from 4ms∼10ms. Then using this Alexandrite laser system with the pulse width 10ms and the beam size 7mm, hair removal was performed on the back portion of a human hand and leg. This study shows that treatment by the long-pulsed Alexandrite laser produces hair removal with no relevant side effects.

A Study on the Weldability of Magnesium Alloy by Laser Heat Source (III) - Butt Weldability of Sand Casting Magnesium Alloy using Pulsed Nd:YAG Laser - (레이저 열원을 이용한 마그네슘 합금의 용접성에 관한 연구 (III) - Pulsed Nd:YAG 레이저를 이용한 사형주조 마그네슘 합금의 맞대기 용접성 -)

  • Kim, Jong-Do;Lee, Jung-Han;Lee, Mun-Yong
    • Journal of Welding and Joining
    • /
    • v.31 no.2
    • /
    • pp.57-62
    • /
    • 2013
  • Magnesium has good castability and limited workability, so its products have been manufactured by almost casting processes. In this study, a pulsed Nd:YAG laser was used to butt-weld the sand casting magnesium alloys. And the effect of welding conditions such as peak power, pulse width, welding speed was evaluated in detail. As a result of this study, large underfill and plenty of spatter taken place under the conditions with high peak power. Thus, it is recommended to use low peak power and long pulse width to obtain good welds with deep penetration. It is also confirmed that the welding speed and pps(pulse per second) are directly connected at weld defects such as underfill, porosity.