• Title/Summary/Keyword: Pulse Wave Velocity

Search Result 163, Processing Time 0.02 seconds

Diagnostic Tool for Cold Sensation of Hands: A Preliminary Study (수부냉증 진단방법에 관한 기초연구)

  • Ko, Seung-woo;Park, Jong-ju;Kong, Kyung-hwan;Go, Ho-yeon
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • Objectives: The aim of this study was to find an effective medical device to detect cold sensation of hands. Methods: Patients with cold sensation of hands (N=42) were recruited in July 2013. We surveyed patients’ general characteristics, severity of cold sensation, body temperature in Nogung (PC8) and Hyeopbaek (LU4) measured with a digital thermometer, digital infrared thermal imaging, and pulse wave velocity. Results: The relation between severity of cold sensation and temperature in Nogung (PC8) and Hyeopbaek (LU4) was statistically significant. The results showed a higher correlation of severity of cold sensation with Nogung (PC9) than with Hyeopback (LU4) temperature. No other indices were statistical significant. Conclusions: Measuring the Nogung (PC9) temperature is most reasonable for assessing the severity of cold sensation of hands. To generalize this result, however, a large-scale study is warranted.

Characteristics of nanocrystalline ZnO films grown on polyctystalline AlN for wireless chemical sensors (무선 화학센서용으로 다결정 AlN 위에 성장된 나노결정질 ZnO 막의 특성)

  • Song, Le Thi;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.252-252
    • /
    • 2009
  • In this work, the nanocrystalline ZnO/polycrystalline (poly) aluminum nitride (AlN)/Si structure was fabricated for humidity sensor applications based on surface acoustic wave (SAW). In this structure, the ZnO film was used as sensing material layer. These ZnO and AlN(0002) were deposited by so-gel process and a pulse reactive magnetron sputtering, respectively. These experimental results showed that the obtained SAW velocity on AlN film was about 5128 m/s at $h/\lambda$=0.0125 (h and $\lambda$ is thickness and wavelength, respectively). For ZnO sensing layers coated on AlN, films have hexagonal wurtzite structure and nanometer particle size. The crystalline size of ZnO films annealed at 400, 500, and 600 $^{\circ}C$ is 10.2, 29.1, and 38 nm, respectively. Surface of the film exhibits spongy which can adsorb steam in the air. The best quality of the ZnO film was obtained with annealing temperature at 500 $^{\circ}Cis$. The change in frequency response (127.9~127.85 MHz) of the SAW humidity sensor based on ZnO/AlN structure was measured along the change in humidity (41~69%). The structural properties of thin films wereinvestigated by XRD and SEM.

  • PDF

Determinant of Arterial Stiffness in Young Adults

  • Jo Yoon-Kyung;Jeon Justin Y.;Kim Eun-Sung;Jekal Youn-Suk;Eom Yong-Bin;Im Jee-Aee
    • Biomedical Science Letters
    • /
    • v.12 no.3
    • /
    • pp.191-196
    • /
    • 2006
  • Cardiovascular disease (CVD) risk factors may be acting several decades before CVD becomes manifest. Data from young subjects may be valuable in further elucidating at this issue. We evaluated the association between baPWV (brachial-ankle pulse wave velocity) and cardiovascular risk factors in apparently healthy young adults. A total of 46 male and 91 female adolescents aged $18{\sim}25 years$ were studied. baPWV increased in a dose-responsive manner as the number of metabolic syndrome components. In both gender groups, baPWV was positively correlated with age. In males, waist, circumference total cholesterol, and LDL-cholesterol were positively correlated with baPWV, and in females, blood pressure (BP) was positively correlated with baPWV. Age, gender, mean BP, and Homeostasis model assessment insulin resistance (HOMA-IR) were found to be independent factors associated with baPWV levels. In conclusion, mean BP, age, gender, and HOMA-IR were associated with baPWV in young adults. This result suggests that multiple cardiovascular risk factors may be associated with an increased risk of arterial stiffness in young adults.

  • PDF

Clinical Study of Correlation between Retention of Fluid and PWV/ABI (Pulse Wave Velocity, Ankle Brachial Index와 담음(痰飮)의 연관성에 관한 연구)

  • Park, Myung-Won;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-sub
    • Korean Journal of Oriental Medicine
    • /
    • v.10 no.2
    • /
    • pp.73-78
    • /
    • 2004
  • Purpose : The aim of this study was to investigate correlation between retention of fluid and PWV/ABI. Methods : The sample consists of 35 women who took plethynography(VS-1000;Fukuda Co.Ltd, Japan) at Oriental medicine exhibition held in COEX mall from August. 26. 2004 to August. 29. 2004. They were asked the intensity of the symptoms like dizziness or headache, nausea or bowel trouble, coldness in knee, and palpitation(1:none, 2:a little, 3:mild, 4:moderate, 5:severe). Women who answered 1,2 were classified as control group, and women who answered 3,4,5 were experimental group. Result : There was stastically significant correlation between dizziness and ABI Conclusion : It is believed that ABI may be the favorable alternative to the diagnosis of dizziness or headache.

  • PDF

Ship Positioning Estimation Using Phased Array Antenna in FMCW Radar System for Small-Sized Ships (소형 선박용 FMCW 레이더 시스템에서의 위상 배열 안테나를 사용한 선박의 위치 추정)

  • Lee, Seongwook;Lee, Seong Ro;Kim, Seong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1130-1141
    • /
    • 2015
  • Conventionally, a pulse radar is used for middle-sized or large-sized ships to detect other ships or obstacles located at a long distance. However, it is hardly equipped for most of the small-sized ships due to mounting and maintenance costs. Therefore, FMCW(frequency modulated continuous wave) radar is suggested as an alternative for the small-sized ships. Since it operates with low power and has good range resolution for relatively close objects, it is eligible for the small-sized ships. In previously proposed FMCW radar system, it only estimates distance and velocity of a target ship placed in the direction of main beam and is hard to detect several ships simultaneously. Thus, we suggest the method for detecting several ships at the same time by applying MUSIC(multiple signal classification) algorithm to FMCW radar signal received by a phased array antenna. In addition, by combining digital beam forming with the MUSIC algorithm, better angle resolution is achievable.

Distance Sensing of Moving Target with Frequency Control of 2.4 GHz Doppler Radar (2.4 GHz 도플러 레이다의 주파수 조정을 통한 이동체 거리 센싱)

  • Baik, Kyung-Jin;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.152-159
    • /
    • 2019
  • In general, a Doppler radar can measure only the velocity of a moving target. To measure the distance of a moving target, it is necessary to use a frequency-modulated continuous wave or pulse radar. However, the latter are very complex in terms of both hardware as well as signal processing. Moreover, the requirement of wide bandwidth necessitates the use of millimeter-wave frequency bands of 24 GHz and 77 GHz. Recently, a new kind of Doppler radar using multitone frequency has been studied to sense the distance of moving targets in addition to their speed. In this study, we show that distance sensing of moving targets is possible by adjusting only the frequency of a 2.4 GHz Doppler radar with low cost phase lock loop. In particular, we show that distance can be sensed using only alternating current information without direct current offset information. The proposed technology satisfies the Korean local standard for low power radio equipment for moving target identification in the 2.4 GHz frequency band, and enables multiple long-range sensing and radio-frequency identification applications.

A Study on Analysis of Beat Spectra in a Radar System (레이다 시스템에서의 비트 스펙트럼 분석에 관한 연구)

  • Lee, Jong-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2187-2193
    • /
    • 2010
  • A specific radar system can be implemented more easily using the frequency modulated continuous wave comparing with the pulse Doppler radar. It also has the advantage of LPI (low probability of interception) because of the low power and wide bandwidth characteristics. These radars are usually used to cover the short range area and to obtain the high resolution measurements of the target range and velocity information. The transmitted waveform is used in the mixer to demodulate the received echo signal and the resulting beat signal can be obtained. This beat signal is analyzed using the FFT method for the purpose of clutter removal, detection of a target, extraction of velocity and range information, etc. However, for the case of short signal acquisition time, this FFT method can cause the serious leakage effect which disables the detection of weaker echo signals masked by strong side lobes of the clutter. Therefore, in this paper, the weighting window method is analyzed to suppress the strong side lobes while maintaining the proper main lobe width. Also, the results of FFT beat spectrum analysis are shown under various environments.

Change in Ultrasonic Characteristics with Isothermal Heat Treatment of 2.25Cr-1Mo Steel (등온열처리에 따른 2.25Cr-1Mo강의 초음파 특성 변화)

  • Nam, Young-Hyun;Baek, Un-Bong;Park, Jong-Seo;Nahm, Seung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.353-358
    • /
    • 2013
  • The ultrasonic characteristics of 2.25Cr-1Mo steel were investigated in relation to the isothermal heat treatment temperature and time. Charpy impact tests and hardness tests were conducted on individual specimens with three different heat treatment conditions. A pulse-echo method with longitudinal waves was used to measure the attenuation and velocity of ultrasonic waves. The FATT (fracture appearance transition temperature) increased with an increase in the isothermal heat treatment time, which implies that the toughness decreased. As the isothermal heat treatment time and temperature increased, the longitudinal wave velocity and ultrasonic attenuation coefficient were raised.

Effects of combined exercise on the blood inflammatory factors, DHEA-s and arterial stiffness of elderly women (복합운동이 고령여성의 혈중 염증인자, DHEA-s 및 동맥경직도에 미치는 영향)

  • Ha, Soo-Min;Kim, Jung-Sook;Kim, Ji-Hyeon;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1096-1107
    • /
    • 2018
  • The purpose of this study was to investigate the effects of combined exercise on blood inflammatory factors, DHEA-s and arterial stiffness in elderly women. The subjects were 42 elderly females volunteers, aged 70 to 85 years, composed of the combined exercise group (n=21) and control group (n=21). The 60 minute combined exercise program(aquarobics 1 time/week, strength exercise 2 times/week) was performed 3 times per week for 12 weeks, and the intensity was progressively increased every 4 weeks(1-4 weeks: RPE 12 to 13, 5-8 weeks: RPE 13 to 14, 9-12weeks: RPE 14 to 15). The test data were analyzed by two-way repeated measures ANOVA, paired t-test, independent t-test and the alpha level of .05 was set for all tests of significance. As a result, the combined exercise for 12 weeks reduced the inflammatory response of elderly women, and DHEA-s was found to have a positive effect on aging hormone. The arterial stiffness decreased the central arterial blood pressure (systolic and diastolic), prevented the increase of the pulse pressure and the wave increase index, and decreased the pulse wave velocity. These results suggest that regular and continuous combined exercise may be recommended for the healthy aging and longevity of elderly women by inducing anti-inflammation effect and improving the aging hormonal function and the vascular health.

Image Evaluation and Association Analysis of the Cardiovascular Disease of the Degree of Pancreatic Steatosis in Ultrasonography

  • Cho, Jin-Young;Ye, Soo-Young;Ko, Seong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • Increasing fat tissue of obese people, increases the rate of cardiovascular disease, diabetes, metabolic syndromes and dyslipidemia. An increase in the focal tissue of pancreas is a known risk factor of these diseases. Although there exists sufficient research on the diagnosis and treatment of pancreatic cancer, studies have been done on fatty pancreas. In this study, based on ultrasound imaging and using a texture characteristic of GLCM, fatty pancreas was divided into three categories: mild, moderate and severe. We compared and analyzed the three groups was by Pancreatic ultrasonography and body characteristics, serological tests, pressure and the degree of arteriosclerosis, against normal control group. The following parameters of control and test groups were measured: WC (waist circumference),BMI (body mass index), TC (total cholesterol), TG (triglyceride), HDL-C (High-density lipoprotein cholesterol) and LDL-C (Low-density lipoprotein cholesterol), SBP (systolic blood pressure), BST (Blood Sugar Test) and aortic PWV (pulse wave velocity). We observed the values correspondingly increasing fat deposition. However, ABI (Ankle Brachial pressure index) stenosis and HDL-C levels decreased with increasing fat deposit (p <0.05); a drop in these parameters are known to be harmful to the human body. The difference in texture characteristics between normal control group and pancreatic fatty group (mild, moderate, and severe) was statistically confirmed. Ultrasound imaging of pancreatic steatosis categorized the disease as mild, moderate and severe based on the characteristic texture. In conclusion, we observed on increase in metabolic syndrome, dyslipidemia, and arteriosclerosis, proportional to the degree of pancreatic fat deposition. The escalation of these diseases was confirmed and was directly related with predictors of cardiovascular diseases.