• Title/Summary/Keyword: Pulse Tracking

Search Result 135, Processing Time 0.025 seconds

A Utility Interactive Photovoltaic Generation System using PWM Chopper and Current Source Inverter (PWM 쵸퍼와 전류형 인버터를 이용한 계통연계형 태양광발전시스템)

  • 이승환;성낙규;오봉환;검성남;이훈구;김용주;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.323-329
    • /
    • 1998
  • In this paper, we compose of the utility interactive photovoltaic(PV) generation system with a PWM stepdown chopper and a current source inverter. The stepdown chopper is controlled by the several gate pulses (twice frequency of utility voltage, square pulse and without the chopper) of chopper part to reduce pulsation of DC current and size of DC reactor. PV current only is measured for maximum power point tracking without any influence on the variation of insolation and temperature. Therefore, we can control modulation factor of the chopper to operate at maximum power point of solar cell. And, the utility interactive photovoltaic generation system supplies an AC power to the load and the utility power system.

  • PDF

The Change of Children's Blood Pressure and Factors Affecting the Level of Blood Pressure In Children (아동혈압의 시계열 변화 양상 및 평균혈압에 관련된 요인 분석)

  • Suh, Il;Kim, Il-Soon;Nam, Chung-Mo;Lee, Soon-Young;Oh, Hee-Chul;Kim, Chun-Bae;Park, Eun-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.3 s.27
    • /
    • pp.303-312
    • /
    • 1989
  • To show the distribution and change of blood pressure according to age and to find factors affecting the level of blood pressure in primary school children, a follow-up study was conducted from 1986 to 1989 on 401 first grade children attending primary school in Kangwha County in 1986 and their parents. The blood pressure of the children was significantly increased according to age. The average annual increase was 1.8mmHg in systolic blood pressure and 2.5mmHg in diastolic blood pressure. The level of blood pressure did not show any significant difference in both sexes. Among children who were at or above the 80th percentile of blood pressure in the first grade, 35 and 30% of them have remained at the same level of systolic and diastolic blood pressure respectively in the fourth grade. But we could not find any significance in the tracking of blood pressure of children who were at or above the 90th percentile of blood pressure in the first grade. Weight and pulse rate were shown to be significant factors affecting systolic blood pressure in children of both sexes and mother's blood pressure and skinfold thickness were also affected systolic blood pressure in girls. The variables significantly affecting diastolic blood pressure were arm circumference and pulse rate for boys and height and pulse rate for girls.

  • PDF

Performance Analysis of Sensor Systems for Space Situational Awareness

  • Choi, Eun-Jung;Cho, Sungki;Jo, Jung Hyun;Park, Jang-Hyun;Chung, Taejin;Park, Jaewoo;Jeon, Hocheol;Yun, Ami;Lee, Yonghui
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.303-314
    • /
    • 2017
  • With increased human activity in space, the risk of re-entry and collision between space objects is constantly increasing. Hence, the need for space situational awareness (SSA) programs has been acknowledged by many experienced space agencies. Optical and radar sensors, which enable the surveillance and tracking of space objects, are the most important technical components of SSA systems. In particular, combinations of radar systems and optical sensor networks play an outstanding role in SSA programs. At present, Korea operates the optical wide field patrol network (OWL-Net), the only optical system for tracking space objects. However, due to their dependence on weather conditions and observation time, it is not reasonable to use optical systems alone for SSA initiatives, as they have limited operational availability. Therefore, the strategies for developing radar systems should be considered for an efficient SSA system using currently available technology. The purpose of this paper is to analyze the performance of a radar system in detecting and tracking space objects. With the radar system investigated, the minimum sensitivity is defined as detection of a $1-m^2$ radar cross section (RCS) at an altitude of 2,000 km, with operating frequencies in the L, S, C, X or Ku-band. The results of power budget analysis showed that the maximum detection range of 2,000 km, which includes the low earth orbit (LEO) environment, can be achieved with a transmission power of 900 kW, transmit and receive antenna gains of 40 dB and 43 dB, respectively, a pulse width of 2 ms, and a signal processing gain of 13.3 dB, at a frequency of 1.3 GHz. We defined the key parameters of the radar following a performance analysis of the system. This research can thus provide guidelines for the conceptual design of radar systems for national SSA initiatives.

Detection of Indication of Electric Accident in Simulated Electric Equipments Using Standard Deviation and Probability Distribution (표준편차와 확률분포를 이용한 모의전기설비에서 사고징후 검출)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.11-16
    • /
    • 2009
  • This paper describes a detecting method for indication of an electric accident in electric equipments. For that, loads of electric equipment is consisted of incandescent lamps. And the electric accident is simulated a tracking test apparatus according to KS C IEC (Korea Standard C International Electrostatic Commission) 60112 at some part of the simulation of the electric equipment. Simulated electric accident is occurred from static states through discharge in progress, carbon formation to tracking breakdown. The total current of electric equipments is measured and analyzed for detecting of indication of the electric accident using a current monitor. For the result, as an electric accident processed, as a current pulse is bigger and a ratio of appearance also increases at certain part of current waveforms. And standard deviation and probability distribution for certain part of current waveforms show remarkably different pattern in each step of electric accident which is irrespective of amount of load.

High-Frequency DC Link Inverter for Grid-Connected Photovoltaic System (고주파링크방식을 이용한 PV용 PCS의 고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1313-1315
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency inverter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AD filter. The high frequency inverter bridge switching at 20kHz is used to generate bipolar PWM pulse, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. In this paper, the control algorithm for synchronous current feedback control method and a maximum power point tracking (MPPT) method using DSP are described. And, the simulation and experimental results are shown to verify the validity of the proposed system.

  • PDF

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.

Welding characteristics of Metal bellows using a pulsed Nd:YAG laser (펄스 레이저를 이용한 벨로우즈 용접특성에 관한연구)

  • Kim, Jeng-O;Lee, Jae-Hoon;Suh, Jeong;Lee, Seung-Woo
    • Laser Solutions
    • /
    • v.15 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Pulse laser welding was performed on C22 metal bellows. The results can be summarized as follows: Laser welded metal bellows had less thermal distortion, narrow HAZ, high aspect ratio in comparison with other welding processes like TIG, Plasma welding. Laser welded bellows has higher tensile strengths than that C22 base metal. The value of hardness in laser weld metal was measured 100-120 Hv, it was decreased compared to the base metal. It is reasoned that due to the annealed by heat input during the laser welding.

  • PDF

Validation Experiments for a Holographic Particle Velocimetry System (펄스 홀로그래프를 이용한 입자 속도 측정 시스템의 검증 실험)

  • Oh, Dai-Jin;Choo, Yeon-Jun;Kang, Bo-Seon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.714-719
    • /
    • 2001
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this research, the optical system for double pulse holographic recording and reconstruction of particle images was developed. Validation experiments for the developed system were conducted measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The measurement results of distance between glass beads, size, and velocities of them using holographic method compared reasonalbly well with the known values within acceptable range of errors.

  • PDF

A Study on the Development of Charging Controller in Stand-Alone PV Power Generation System (독립형 태양광 발전 시스템 충전제어기 개발에 관한 연구)

  • 곽준호;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.916-921
    • /
    • 2004
  • This paper describes microprocessor-based control of photovoltaic power conditioning system. where the microprocessor is responsible for control of output power in accordance with the generated array DC power. The microprocessor includes the control algorithm of maximum power point tracking and converter control algorithm. In this power, we have designed a MPPT(Maximum Power Point Tracker) algorithm with environment factors and a PWM(Pulse Width Modulation) algorithm for high efficiency. The controller has been tested in the laboratory with the power conditioner and shows excellent performance.

A New Resonant H/B Inverter Having Load Freewheeling Modes (부한 환류모드를 갖는 새로운 반 브리지 공진형인버터)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.153-156
    • /
    • 2004
  • This paper presents a new circuit topology of the half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in the load freewheeling modes, pulse width modulation (PWM) control method can be used for the output power control. The proposed half-bridge inverter should keep unity output displacement factor under the load-impedance varying conditions, if a new PWM control scheme based on the resonant frequency tracking algorithm is adopted. In this paper, electrical characteristics, and losses analysis of the proposed half-bridge resonant inverter are described. Simulation and experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge resonant inverter are presented and discussed.

  • PDF