• 제목/요약/키워드: Pulse Sampling

검색결과 140건 처리시간 0.031초

Ground Penetrating Radar를 사용한 지하설비 탐사에 관한 연구 (Exploration of Buried Facilities by GPR)

  • 손수국;전경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.30-33
    • /
    • 2001
  • This paper discusses the system design of a synthetic aperture radar system based on a pulse-echo radar. The design consists of an ultra-wide bandwidth antenna, an amplitude modulation, timing stabilities, and high speed a/d conversions with an equivalent-time sampling. Experiment results show that GPR(Ground Penetrating Radar) can be used to explore buried electric facilities.

  • PDF

A New TE/TR Reduction Technique in MR Pulse Sequences and Its Application to Radial Imaging

  • 김용권;류연철;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.18-18
    • /
    • 2003
  • 목적: MRI 시스템에서 얻어지는 Data는 TR(Repetition Time)과 TE(Echo Time)에 따라서 신호 대잡음비(SNR), 조직들간의 대조도(Contrast), Artifact 및 촬영시간이 결정된다. 이 연구에서는 TR/TE를 줄이는 기법을 이용한 Radial Imaging 영상기법을 제시하고자 한다. 대상 및 방법: 일반적인 Radial Imaging 기법에 HASTE 기법과 Non-uniform sampling 기법의 특징을 이용하여 구현하였으며, TR/TE를 줄일 수 있었으며 얻어진 K-space Data는 가변주파수 역 Fourier Transform을 이용하여 Projection Data를 재구성한 후 Back Projection 기법을 이용하여 최종 영상을 재구성한다.

  • PDF

이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계 (Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC)

  • 신영산;위재경;송인채
    • 전자공학회논문지
    • /
    • 제50권9호
    • /
    • pp.68-73
    • /
    • 2013
  • 본 논문에서는 수면 중에 사용자의 건강상태를 모니터링 하기 위한 U-health 시스템으로 맥박 수와 맥박 파형 검출 회로를 제안하였다. 제안된 검출 회로의 출력은 배터리의 교체 없이 장시간 사용하기 위하여 건강 상태에 따라 맥박 수 또는 맥박 파형이 선택된다. 이러한 동작을 위해 제안된 신호 검출 회로는 ADC 모드 또는 카운트 모드로 동작하는 이중 모드 ADC와 간단한 디지털 로직으로 구성된 판별기를 사용하였다. 우선 초기에는 카운트 모드로 동작하는 이중 모드 ADC를 통해 4초 동안의 맥박 수를 검출한다. 검출된 맥박수는 판별기에서 1분간 누적한 뒤 건강 상태를 판별한다. 건강 이상 등으로 맥박 수가 설정된 정상 범위를 벗어난 경우 이중 모드 ADC는 ADC 모드로 동작하며 맥박 파형을 1kHz의 샘플링 주파수로 10bit의 디지털 데이터로 변환한다. 데이터는 버퍼에 저장하였다가 620kbps의 속도로 RF Tx를 통해 단말기로 전송한다. 이때 RF Tx는 모드에 따라 1분 혹은 1ms 간격으로 동작한다. 제안된 신호 검출 회로는 $0.11{\mu}m$ 공정으로 설계하였으며 $460{\times}800{\mu}m^2$의 면적을 차지한다. 측정결과 제안된 검출 회로는 1V의 동작 전압에서 카운트 모드에서는 $161.8{\mu}W$, ADC 모드에서는 $507.3{\mu}W$의 전력을 소모한다.

우주 전파 신호의 고속 디지털 변환 장치 개발과 적용 (Development and Observation Result of High Speed Digital Conversion System of Astronomical Radio Siginal)

  • 강용우;송민규;위석오;제도흥;이성모;김승래
    • 한국전자통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1009-1018
    • /
    • 2017
  • 우리는 한국우주전파관측망(: Korea VLBI Network: KVN)에 적용 가능한 새로운 디지털 샘플러를 개발하였다. 이 샘플러는 1024MHz 샘플링으로 2bits/sample의 성능을 가지고 있다. 입력 기준 주파수 Clock은 1PPS(: Pulse per second)와 10MHz를 사용하며, 1PPS 신호에 동기되어 UTC(: Universal Time Coordinated) 시각정보가 출력된다. 샘플링된 데이터 출력은 시각정보를 포함한 VSI(: VLBI Standard Interface)규격을 채택하고 있다. 개발된 샘플러의 성능을 검증하기 위하여, KVN 울산전파천문대에 설치하여 우주 전파 관측 시험을 수행하였다. 관측시험 결과, 안정적인 성능을 보여 주었다. 본 논문에서는 새로 개발된 샘플러와 관측 시험 결과를 발표하고자 한다.

PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구 (A Study on Evaluation of Human Arousal Level using PPG Analysis)

  • 김치중;황민철;김종화;우진철;김용우;김지혜
    • 대한인간공학회지
    • /
    • 제29권1호
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구 (Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency)

  • 정현주;김도완;이동훈;김중만;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

상용교류방전 자기자극장치의 동작특성 (Commercial frequency AC discharge magnetic stimulation operating characteristics)

  • 김휘영
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2685-2692
    • /
    • 2009
  • 펄스형 자기자극장치를 누설변압기의 1차측 스위칭 제어로 교류(60hz) 스위칭 제어를 하여 비용과 크기면에서 기존의 전원장치로 구성된 것보다 약30w의 소용량으로 구성을 할 수가 있었다. 펄스반복률은 자기자극장치의 출력제어를 5-60hz로 적절하게 조절하였다. 이 자석 자극에서는, 고전압 출력 회로를 위한 낮은 전압 열리는 반복 통제가 고전압 표본 추출을 피하기 위하여 채택되며, 또는 스위칭제어와 고전압 누설 변압기는 고전압 하나로 조정된 낮은 전압 펄스를 개조하기 위하여 사용된다. ZCS (영전류스위칭) 회로 및 DSP & FPGA는 SCR의 게이트 신호를 정확하게 통제하기 위하여 사용된다. 펄스 반복 비율은 AC 선과 높은 누설 유도자의 주파수 때문에 60Hz에 의해 제한된다. 최대 자석자극장치의 출력은6 0Hz, 각각 40, 80, 120, $160^{\circ}$, SCR 게이트의 펄스반복 비율로 33W에 관하여 트리거 각 $90^{\circ}$에 대한 전체적인 출력으로 얻어졌다.

위상이 다른 4개의 클럭을 이용한 시추공 레이다 수신기용 ETS 샘플러 설계 (ETS Sampler design for borehole radar receiver using 4 different clock phases)

  • 유영재;오재곤
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.680-687
    • /
    • 2018
  • 시추공 레이다는 지하자원 및 지질탐사 목적으로 사용되는 레이다로서 수 ns의 펄스폭을 갖는 전자파를 송신하고 탐사 대상으로부터 반사되어 입력되는 수십에서 수백MHz의 반사파를 수신하기 위하여 고속 샘플러가 반드시 필요하다. 수십MHz의 샘플링 클럭 주파수로도 수GHz급의 샘플링 성능을 낼 수 있는 ETS(Equivalent-Time Sampling)는 시추공 레이다용 수신기의 샘플러로 사용이 적합하다. ETS 샘플러 설계에 있어 가장 중요한 요소인 샘플링 클럭 지연을 제어하는 방법으로 본 연구에서는 하나의 클럭 소스에 대해 각 $90^{\circ}$씩 위상 차이를 가지는 4개의 클럭을 이용한 방법을 제시하였다. 제안하는 방법은 기존의 지연 발생기를 이용하는 방법보다 설정한 구간 내에서 데이터를 획득하는 시간이 1/23로 단축 가능하다. 구현된 샘플러를 기존 시추공 레이다의 수신기에 적용하면 단축된 샘플링 시간으로 인해 추가로 64회 누적이 가능해져 지하 터널 탐사를 위한 수신신호 품질 개선 효과를 얻을 수 있다. 또한, 목표 샘플링 범위를 만족하기 위해서 여러 개의 샘플링 클럭 지연제어 로직을 사용하는 기존 방식에 비하여 하나의 지연제어 로직을 사용함으로써 그간 반드시 필요하였던 보정 과정의 생략이 가능하다. 그 결과 시스템의 구조를 단순화할 수 있었으며 균일한 샘플러의 구현이 가능하였다.

Self-Tuning Control of SRM for Maximum Torque with Current and Shaft Position Feedback

  • Seo Jong-yun;Yang Hyong-yeol;Kim Kwang-Heon;Lim Young-Cheol;Cha Hyun-Rok;Jang Do-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.351-354
    • /
    • 2001
  • In this paper, we present self-tuning control of switched reluctance motor for maximum torque with phase current and shaft position sensor. Determination method of turn-on/off angle is realized by using self-tuning control method. During the sampling time, micro-controller checks the number of pulse from encoder and compare with the number of pre-checked pulse. After micro-controller calculates between two data, it moves forward or backward turn-off angle. When the turn-off angle is fixed optimal turn-off angle, the turn-on angle automatically moves forward or backward by a step using self-tuning control method. And then, optimal turn-off angle is searched once again. As such a repeating process, turn-on/off angle is moved automatically to obtain the maximum torque. The experimental results are presented to validate the self-tuning algorithm.

  • PDF

누설 변압기를 이용한 반파 AC 주파수 제어형 $CO_2$ 레이저의 전원장치 개발 (The development on Power supply for Pulsed $CO_2$ laser using half-rectified AC frequency control and leakage transformer)

  • 정현주;김도완;이동훈;이유수;김희제;조정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.82-85
    • /
    • 2000
  • We introduce pulsed $CO_2$ laser power supply excited by half-wave rectified 60Hz AC discharge some advantage of cost and size compared to a typical pulsed power supply. AC frequency is adjusted from 10Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage AC discharge circuits is employed to avoid the HV sampling or switching. The control is achieved by using a ZCS circuit and a PIC one-chip microprocessor that control the gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to a high leakage inductance. The maximum laser output was obtained about 20W at the condition of total pressure, 18Torr and pulse repetition rate,60Hz.

  • PDF