• 제목/요약/키워드: Pulse Radiation

검색결과 241건 처리시간 0.028초

원자간력 현미경(AFM)과 펨토초 펄스 레이저를 이용한 나노 형상 가공 (AFM-based nanofabrication with Femtosecond pulse laser radiation)

  • 김승철;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.149-150
    • /
    • 2006
  • We describe a novel method of scanning probe nanofabrication using a AFM(atomic force microscopy) tip with assistance of Femtosecond laser pulses to enhance fabrication capability. Illumination of the AFM tip with ultra-short light pulses induces a strong electric field between the tip and the metal surface, which allows removing metal atoms from the surface by means of field evaporation. Quantum simulation reveals that the field evaporation is triggered even en air when the induced electric field reaches the level of a few volts per angstrom, which is low enough to avoid unwanted thermal damages on most metal surfaces. For experimental validation, a Ti: sapphire Femtosecond pulse laser with 10 fs pulse duration at 800 nm center wavelength was used with a tip coated with gold to fabricate nanostructures on a thin film gold surface. Experimental results demonstrate that fine structures with critical dimensions less than ${\sim}10nm$ can be successfully made with precise control of the repetition rate of Femtosecond laser pulses.

  • PDF

기체 방전관의색상 제어에 관한 연구 (A Study on Color Control in Gas Discharge Tube)

  • 이종찬;청야정명;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.285-288
    • /
    • 1996
  • The electronic operation of the gas discharge tube is controlled by the electrical energy as sinusoidal waveform in arbitrary frequency range, or as a sequence of pulses at a wide range of duty cycle, the gas composition, the kind of electrode and the vessel geometry. In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of IIg-Ne ( 10 Torr ), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency and pulse width in high voltage. As increasing pulse width and frequency in the gas discharge tube, the phenomenons that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist. The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing pulse width and frequency. The changing method of pulse width and frequency has been shown to be suitable for the luminous color control.

  • PDF

방사선감시장치에 관한 연구 (A Study on the Radiation Monitor)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제10권2호
    • /
    • pp.16-22
    • /
    • 1973
  • γ선 또는 β선의 방사선에 의한 오염을 신속히 발견하고 그러한 위험이 있는 장소의 계수률을 항상 감시할 수 있는 방사선 감시장치에 관한 연구이다. 이 장치에 사용되는 회로중 펄스 증폭기에 관한 상세한 해석을 하였으며 파고선별회로의 설계식을 유도하였다. 장치는 완전 트랜지스터화 하였고 방사선의 계수률은 최고 10k pps까지 미터로 읽을 수 있는 동시에 확성기로도 들을 수 있게 하였다.

  • PDF

초음파진동자의 복수배열에 의한 지향성가변에 관한 연구 (A Study on the Control of the Radiation Pattern of an Ultra-Sonic Beam by the Plural Arrangement of the Transducers)

  • 신형일
    • 한국항해학회지
    • /
    • 제3권2호
    • /
    • pp.21-30
    • /
    • 1979
  • Echo sounder and Doppler sonar are to theultra-sonic transducers for measuring the depth and the ship's speed respectively. To measure the depth and speed with a single transducer, it is required to control the ultra-sonic beam to optional direction. In the past, the direction of the transducer itself is varied, but such a method provoked much problems in the mechanical design of the equipment. This paper deals with the method to control beam direciton by the phase control of the plural arrangement of transducers, and the results are studied by a computer simulation. The remarkable results of the study is condensed as follows; 1. The greater the interval of arrangement between transducers, the sharper the radiation pattern is, but in this case, the level of undesired sidelobe is also increased. 2. The control of radiation pattern up to 60 degree can be achieved by an adequate arrangement of more than 10 transducers. 3. It is shown that a simultaneous measurement of both depth and speed can be achieved by alternating directivity of the pulse by the method proposed in this paper.

  • PDF

Primary Radiation Force to Ultrasound Contrast Agents in Propagating and Standing Acoustic Field

  • Seo, Jong-Bum
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권1E호
    • /
    • pp.1-8
    • /
    • 2009
  • Primary radiation force on ultrasound contrast agents (UCA) in a propagating and standing acoustic field was explored. A specific ultrasound contrast agent $Albunex^{(R)}$ and $Optison^{(R)}$ were chosen for simulation. The model was developed based on a shelled bubble model proposed by Church. The numerical simulation suggests that bubble translational motion is more significant in therapeutic ultrasound due to higher intensity and long pulse duration. Even a single cycle of a propagating wave of 4 MPa at 1 MHz can cause a bubble translational motion of greater than $1{\mu}m$ which is approximately one tenth of capillary. Hence, UCA characteristics can be significantly changed in therapeutic ultrasound without rapid bubble collapses.

Equivalent Noise Charge Measurements in Hydrogenated Amorphous Silicon Radiation Detectors

  • Kim, Ho-Kyung;Hur, Woo-Sung;Gyuseong Cho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.973-979
    • /
    • 1995
  • The input equivalent noise charge (ENC) of hydrogenated amorphous silicon radiation detector diodes was measured and analyzed. The noise sources of amorphous silicon diodes were analyzed into three sources; shot noise, flicker noise and thermal noise from the contact resistance. By comparing the measured ENC with the calculated signal charge in uniform generation case, the signal-to-noise ratio (S/N) for the sample diodes is estimated as a function of the detector bias and the shaping time of Gaussian pulse shaper. The maximum S/N occurred at the bias level just above the full depletion voltage for shaping time of 2∼3 ${\mu}$sec. The developed method is useful in optimum design or amorphous silicon p-i-n diodes for charged particulate radiation spectroscopy.

  • PDF

Transient Photocurrent in Amorphous Silicon Radiation Detectors

  • Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shinn, Kyung-Sub;Cho, Gyu-Seong
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.468-475
    • /
    • 1997
  • The transient photocurrent in amorphous silicon radiation detectors (n-i-n and forward biased p-i-n) were analyzed. The transient photocurrents in these devices could be modeled using multiple trap levels in the forbidden gap. Using this model the rise and decay shapes of the photocurrents could be fitted. The decaying photocurrent shapes of the p-i-n and n-i-n devices after a short duration of light pulse showed a similar behavior at low dark current density levels, but at higher dark current density levels the photocurrent of the p-i-n diode decayed faster than that of the n-i-n, which could be explained by the decreased electron lifetimes in the forward biased p-i-n diode at high dark current densities. The transient photoconductive gain behaviors in the amorphous silicon radiation detectors are discussed in terms of device configuration, dark current density and time scale.

  • PDF

Technology Of Application Of Multifrequency Signals To Create An Electromagnetic Field

  • Strembitska, Oksana;Tymoshenko, Roman;Mozhaiev, Mykhailo;Buslov, Pavlo;Kashyna, Ganna;Baranenko, Roman V.;Makiievskyi, Oleksii
    • International Journal of Computer Science & Network Security
    • /
    • 제21권2호
    • /
    • pp.40-43
    • /
    • 2021
  • In the article of instability on the peak power level, duration and repetition period of a multifrequency space-time signal, we calculated the maximum values of the errors of the parameters of the laws of spatial-phase-frequency control. Requirements for the accuracy of the location of the phase centers of the emitters in a cylindrical phased array antenna with pyramidal horns; it is advisable to calculate the radiation field using single-stage and multi-stage distribution laws. The phase centers of individual radiation sources of a cylindrical phased array antenna have been studied; they have almost no effect on the duration and period of recurrence.

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

적외선 감지 센서를 이용한 점 용접부의 검사 (Inspection of the spot welding using IR sensor)

  • 임대철;박인태;강형식;권대갑
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.132-140
    • /
    • 1999
  • This paper suggests a monitoring method for the pulsed laser spot welding of the thin metal sheets using a point IR(InfraRed) sensor. A new criterion was introduced and the experimental results guaranteed the efficiency. The ideal radiation feature was derived from the mathematical model and was simulated. The radiation feature is robust to withstand the change of measuring condition and can be used to detect the absorbed laser energy. In an experiment, the radiation feature was examined for the differect laser energy. The pulse width and the laser power was variated and the radiation feature was examined. In the other experiment, the relationship between the weld strength and radiation feature was examined. Artificial Neural Network(ANN) was employed to find out the relationship. The correlation coefficient between the real strength and the estimated strength is high as 0.94 and the mean square error is low as 0.64 kgf learned parts. Another group of the welds was used to appraise the learning efficiency. The correlation coefficient between the measured and the estimated weld strength is high as 0.91.

  • PDF