• 제목/요약/키워드: Pulse Point

검색결과 511건 처리시간 0.021초

Study on the Selection of Representative Pulse Wave

  • Kim, Jong-Yeol;Shin, Sang-Hoon
    • 대한한의학회지
    • /
    • 제29권5호
    • /
    • pp.104-110
    • /
    • 2008
  • Objectives : The purpose of this study is to develop the method of selecting representative pulse wave. Methods : The pulse waves were acquired at the right and the left Guan point(關部) with 1420 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results : In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions : So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave.

  • PDF

고대(古代)의 경맥진단법(經脈診斷法) 중(中) 십이경표본맥진법(十二經標本脈診法)에 관(關)한 연구(硏究) (A study on Twelve meridian Biaoben(標本) pulse diagnosis method among the ancient meridian diagnosis method)

  • 이동휘;황민섭;윤종화
    • Journal of Acupuncture Research
    • /
    • 제21권1호
    • /
    • pp.21-32
    • /
    • 2004
  • Objective: A study on $\ll$Lingchui, 靈樞 Weiqi, 衛氣$\gg$ which descripted Twelve meridian Biaoben(標本) pulse diagnosis method. Methods: A study on Twelve meridian Biaoben(標本) pulse diagnosis method which has the cognizance of Biaoben(標本) on upper and low twelve meridian as linear upper and low pulse diagnosis point. Results: Twelve meridian Biaoben(標本) pulse diagnosis method is derived from using each twelve meridian pulse diagnosis and it can be explained that the ben(本) pulse point on wrist ankle and the biao(標) pulse point on thorax axillary neck head face correspond to upper and low part of meridian for diagnosis and treatment which become the theory of "treat upper disease on low part, treat low disease on upper part". Conclusions: Twelve meridian Biaoben(標本) pulse diagnosis method started confirming the general concept of Jue-symptom(厥症) and Jue-symptom(絶症) and developed upper and low pulse diagnosis point or acupuncture point to treatment.

  • PDF

《영추(靈樞)·경맥(經脈)》의 촌구인영맥진(寸口人迎脈診)에 관(關)한 연구(硏究) (A study on diagnosis method by chonguinyoung pulse(寸口人迎脈診) based on 《Youngchu·Kyoungmaek 靈樞·經脈》)

  • 신광순;장준혁;윤종화
    • Journal of Acupuncture Research
    • /
    • 제19권1호
    • /
    • pp.203-209
    • /
    • 2002
  • Objective : The chonguinyoung pulse diagnosis method is convenient than twelve meridian pulse diagnosis method The $\ll$Maek-bup(脉法)$\gg$ are founded at Mawangtweo(馬王堆) of the han dynasty tomb in 1973, but it could diagnosis the exsitance of illness of twelve meridian also . Methods : In accordance to $\ll$Naekuoung(內經)$\gg$ inyoungmaek(人迎脈) in could be taken at the which is the pulse point of carotid artery on the line of foot yangmyoung stomach meridian (足陽明胃經) and chongumaek (寸口脈) at the taeyoun acu-point (太淵穴) pulse point on the line of hand taeyeun lung meridian (手太陰肺經). Results : Chonguinyoung pulse diagnosis method could be emphased on the point of diagnosing sick person and healthy person by the balance of yin (陰) yan (陽) composition in the body. Conclusion : Chonguinyoung pulse diagnosis method could be the indication of improvement and progress of disease also it could be adapt to diagnosis of twelve meridian and it is impossible to making choice of acupuncture, medication, moxibustion, vene-section and strengthing-eleminating treatment method (補瀉方法).

  • PDF

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

토노메트리 측정 관점에서의 부침맥 고찰 (Review on Floating Pulse and Sinking Pulse in the View Point of Tonometric Measurement)

  • 이전;이유정;유현희;이혜정;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권2호
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, floating pulse and sinking pulse are frequently used for diagnosis about where disease is located and how much severe they are. However, in what mechanism floating pulse and sinking pulse arise is not known well. There are two point of views on substantial of floating pulse and sinking pulse. The first one is the floating and sinking degrees is the expression on the depth of pulsation. And, the second one is floating and sinking pulse is based on the response of pulsation to the indent pressure on radial artery. In this paper, we discussed these two opinions in the view point of tonometric measurement. The process for diagnosis on floating pulse and sinking pulse is similar to the tonometric measurement for non invasive blood pressure or intraocular pressure. We modelled the degrees of depth of pulsation with different indent pressures for initial pulsation feeling and different slopes of indent pressure lines. From this modelling, we can confirm the effect of pulsation depth on P-H curve, that is, in the model where lower pulsation is assumed, the shift of optimal indent pressure to the right was observed. The response of pulse pressure to the indent pressure was tried to be modelled with the degrees of mean blood pressure. Consequently, we tried to model the phenomenon of floating and sinking pulse for the first. And, from this modelling, we can get abundant understanding on how floating and sinking pulse can be caused. In the further study, we want to prove the suitability of this tonometric measurement based modelling with various studies including ultrasound measurement for the depth of pulsation in different EMI subjects.

  • PDF

혈류역학을 이용한 촌구와 인영의 특성비교 (Comparative study of pulse point using hemodynamics)

  • 신상훈;박대훈;박영재;박영배
    • Journal of Acupuncture Research
    • /
    • 제21권5호
    • /
    • pp.241-248
    • /
    • 2004
  • Objectives : The purpose of this study is to examine the hemodynamic characteristics of pulse point. Methods : The computational analysis algorithms of arterial tree system was derived. In order to investigate the effect of internal organ on the pulse point, the diameter of celiac artery was reduced by half. Results : The sensitivity of flow change at the Inyoung(Renying) is better than that of the Chongu(Cunkou). but the Inyoung was worse than the Chongu in the point of the left and right symmetry. The pressure changes at the Inyoung and the Chongu were in the similar range. Conclusions : It was found from the result that the Chongu shows the more symmetrical hemodynamic characteristics than the Inyoung.

  • PDF

맥파 특징점 검출 알고리즘에 관한 연구 (A Study on Feature Point Detection Algorithm in Radial Pulse)

  • 한순천;이용동;조병서;박영배;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.207-209
    • /
    • 2000
  • In this paper, we developed a feature point detection algorithm that detects upstroke point(S), peak point(P), incisura(C) point from radial pulse waveform which obtained by using the developed radial pulse transducer. As the results of experiment the three kinds of parameters can extracted with effectively from normal radial pulse waveform.

  • PDF

Practical Implementation of Maximum Power Tracking Based Short-Current Pulse Method for Thermoelectric Generators Systems

  • Yahya, Khalid;Bilgin, Mehmet Zeki;Erfidan, Tarik
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1201-1210
    • /
    • 2018
  • The applications of thermoelectric generators (TEGs) have received a lot of attention both in terms of harvesting waste thermal energy and the need for multi-levels of power. It is critical to track the optimum electrical operating point using DC to DC converters controlled by a pulse that is generated through a maximum power point tracking algorithm (MPPT). In this paper, the hardware implementation of a short-current pulse algorithm has been demonstrated under steady stated and transient conditions. In addition, the MPPT algorithm has been proposed, which is one of the most effective and applicable algorithms for obtaining the maximum power point of TEGs. During this study, the proposed prototype has been validated both analytically and experimentally. It has also demonstrated successful performance, which highlights the claimed advantages of the proposed MPPT solution.

지간적 직류Corona의 실질적 검토 (Experimental Study of DC Coronas in Point-to-Plane Short Gap)

  • 오철한;이성만
    • 대한전기학회논문지
    • /
    • 제32권5호
    • /
    • pp.157-163
    • /
    • 1983
  • Positive and negative coronas in point-to-plane short gap have been investigated with the variations of point radius and gap length. Mainly the onset potentials and current pulses under various conditions were measured with a 70 MHz C.R.O. and a precise-controllable D.C. power supply. In the case of negative corona, the Trichel pulse corona, glow corona and spark regions were distinguished apparently and the critical gap lengths between them were also found clearly. In the case of positive corona, there are streamer corona, spark regions and the critical gap length between them, too. The current pulse forms of Trichel pulse corona of negative and streamer pulse corona of positive are similar in rising time, peak-to-peak time and pulse width. The glow corona current shows D.C. component in form.

  • PDF

소프트웨어 펄스 보간기의 성능비교 (Study on the Performance Comparision of Software Pulse Interpolators)

  • 안중환;임현석;이원규
    • 한국정밀공학회지
    • /
    • 제13권9호
    • /
    • pp.62-69
    • /
    • 1996
  • Interpolator is a very important element in NC machines in that it controls tool path and speed. In this paper, studied were extensive interpolation characteristics of reference pulse method among various interpolation and pulse generation methods. Specifically, processing speed and path error of DDA, SPD and SFG methods were compared and analyzed against line, circle and elipse. As a result, in the point of processing speed, SPD method was found to be the best for line interpolation, SFG method for circle and ellipse, and DDA method was found to be the slowest for all paths. In the point of path error, DDA method was found to have the biggest error for all kinds of paths.

  • PDF