• Title/Summary/Keyword: Pulse Magnetic Treatment

Search Result 36, Processing Time 0.018 seconds

Chopper Application for Magnetic Stimulation

  • Choi, Sun-Seob;Lee, Sun-Min;Kim, Jun-Hyoung;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.213-220
    • /
    • 2010
  • Since the hypothalamus immediately reacts to a nerve by processing all the information from the human body and the external stimulus being conducted, it performs a significant role in internal secretion; thus, a diverse and rapid stimulus pulse is required. By detecting Zero Detector accurately via the application of AVR on-Chip (ATMEL) using commercial electricity, chopping generates a stimulus pulse to the brain using an IGBT gate to designate a new magnetic stimulation following treatment and diagnosis. To simplify and generate a diverse range of stimuli for the brain, chopping can be used as a free magnetic stimulator. Then, commercial frequency (60Hz) is chopped precisely at the first level of the leakage transformer to deliver an appropriate stimulus pulse towards the hypothalamus when necessary. Discharge becomes stable, and the chopping frequency and duty-ratio provide variety after authorizing a high-pressure chopping voltage at the second level of the magnetic stimulator. These methods have several aims. The first is to apply a variable stimulus pulse via accurate switching frequency control by a voltaic pulse or a pulse repetition rate, according to the diagnostic purpose for a given hypothalamus. Consequently, the efficiency tends to increase. This experiment was conducted at a maximum of 210 W, a magnetic induced amplitude of 0.1~2.5 Tesla, a pulse duration of $200{\sim}350\;{\mu}s$, magnetic inducement of 5 Hz, stimulus frequency of 0.1~60 Hz, and a duration of stimulus train of 1~10 sec.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Treatment of Bone Repair by Inductively Magnetic Fields

  • Ahn, Jae-Mok;Lee, Woo-Cheol;Kim, Hee-Chan;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.213-217
    • /
    • 1992
  • An inductively coupled magnetical signal (pulse wave, 0.7 to 60Hz, eighteen volts peak to Peak) that was applied non-invasively on the skin surface overlying the approximate site(measure position). In the group with unipolar pulse signal currents produced smaller than in the group with bipolar pulse signal. The signal was transmitted to the active coil, including a time-varying magnetic field: this in turn induced a the-varying electrical field in the field in the bone. It is very important to determine system parameters due to treatment time(healing) and the simplicity. This paper investigation was designed to compare the relative effects of pulsed unipolar currents with the effects of an identical pulsed bipolar currents. Since Inductive coupling is non-invasive and involves portable equipment, it is easy to apply and requires precise localization, it has distinct advantages and field characteristics along the bone for each different signal.

  • PDF

Treatment Stimulator's Pulse of Transcranial Magnetic Stimulation (경두개 자기자극장치의 치료자극 펄스)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.289-296
    • /
    • 2009
  • In this study, I presented power control unit with potential use in the magnetic stimulation of biological systems. The effect of the magnetic stimulation depends on the geometry and orientation of the induced electric field as well as on the current pulse waveform delivered by the stimulator coil. TMS is achieved from the outside of the head using pulses of electromagnetic field that induce an electric field in the brain. There are numerous possibities in the applications TMS, such as diagnosis and therapy through the brain stimulation. These factors are very important to define the equipment requirements and characteristics in that the topology of the power supply and the size and geometry of the coil. The proposed solution is the generation of current pulses with variable amplitude and duration, according to a user defined input. Another solution is the topology that uses elements to store and transfer energy from the power source to the load. In addition to proposed topology, an adequate control strategy and right set of the power circuit parameters made possible to obtain unipolar waves and bipolar waves.

Design of Epitaxy Style Magnetic Curer and Special Quality Embodiment for Nerve Luman Nature Disease Treatment (신경인성 질환치료를 위한 적층형 자기치료기의 설계 및 특성구현)

  • Lee, Jung-Sook;Kim, Whi-Young
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.2
    • /
    • pp.157-174
    • /
    • 2007
  • Result that study to serve to apply epitaxy style magnet nerve curer in nerve human nature disease treatment is as following. Designed probe actually with special quality research about coil probe of magnet curer firstly. Impose and revealed all drives about treatment probe embodying power device using MOSFET that is electric power element secondly. Could receive energy value that is proportional in number to close with actuality coil value by manufacture about treatment coil probe by third and come out. This could embody treatment pulse by disease, and saved pulse third and so on by damping pulse form through a special quality experiment variously specially. High amplitude treatment pulse(great strong) maximizes curative effect at short time and will be bought that demand is magnified greatly at the future in this research.

  • PDF

Assessment of Pulsed Magnetic Field Stimulus by Using Finger Photoplethysmogram and Pressure Pulse Waveform

  • Lee, Jin-Yong;Go, In-Suk;Choi, Jae-Won;Jang, Tae-Sun;Shin, Sang-Hoon;Lee, Hyun-Sook;Hwang, Do-Guwn;Kim, Sun-Wook
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.209-212
    • /
    • 2010
  • Photoplethysmogram (PPG) and pressure pulse waveform (PPW) were compared and evaluated for the efficacy of stimulating knuckles by using the pulsed magnetic field. Both signals were observed simultaneously while the knuckles were exposed for 10 min to the pulsed magnetic field, with maximum field intensity of 0.8 T and transition time of 0.126 msec. After 5 min stimulation of the knuckles, the results showed that the aging indexes calculated from the second derivative of the PPG were increased from -1.913 to 0.072, and that of the PPW from -0.063 to 0.387. However, for the relatively long-term stimulation for 10 min, we found that the values of both the aging indexes of the second derivatives and augmentation index of the PPW returned to the starting level. The changes observed in characteristic factors such as the aging indexes of the second derivatives and augmentation index of the PPW indicate the potential of pulsed magnetic field stimulation as a therapeutic method for the treatment of patients with peripheral vascular disease.

Performance Experiment of Electron Beam Convergence Instrument (Finishing 용 전자빔 집속 장치의 성능 실험)

  • Lim, Sun Jong
    • Laser Solutions
    • /
    • v.18 no.3
    • /
    • pp.6-8
    • /
    • 2015
  • Finishing process includes deburring, polishing and edge radiusing. It improves the surface profile of specimen and eliminates the alien substance on surface. Deburring is the elimination process for debris of edges. Polishing lubricates surfaces by rubbing or chemical treatment. There are two types for electron finishing. The one is using pulse beam. The other is using the convergent and scanning electron beam. Pulse type device appropriates the large area process. But it does not control the beam dosage. Scanning type device has advantages for dosage control and edge deburring. We design the convergence and scan type. It has magnetic lenses for convergence and scan device for scanning beam. Magnetic lenses consist of convergent and objective lens. The lenses are designed by the specification(beam size and working distance). In this paper, we evaluate the convergence performance by pattern process. Also, we analysis the results and important factors for process. The important factors for process are beam size, pressure, stage speed and vacuum. These results will be utilized into systematizing pattern shape and the factors.

Principles of Magnetic Resonance Angiography Techniques

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.209-217
    • /
    • 2021
  • Magnetic resonance angiography (MRA) plays an important role in accurate diagnosis and appropriate treatment planning for patients with arterial disease. Contrast-enhanced (CE) MRA is fast and robust, offering hemodynamic information of arterial flow, but involves the risk of a side effect called nephrogenic systemic fibrosis. Various non-contrast-enhanced (NCE) MRA techniques have been developed by utilizing the fact that arterial blood is moving fast compared to background tissues. NCE MRA is completely free of any safety issues, but has different drawbacks for various approaches. This review article describes basic principles of CE and NCE MRA techniques with a focus on how to generate angiographic image contrast from a pulse sequence perspective. Advantages, pitfalls, and key applications are also discussed for each MRA method.

Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작)

  • Kim, Whi-Young;Choi, Jin-Young;Park, Sung-Jun;Kim, Hee-Je
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.1
    • /
    • pp.153-169
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF