• Title/Summary/Keyword: Pulse Load

Search Result 530, Processing Time 0.021 seconds

EFFICIENT OZONIZER USING VOLTAGE-SOURCE LOAD RESONANT INVERTER WITH PDM AND PWM CONTROL IMPLEMENTATION

  • Kohishi, Yoshihiro;Wang, Shengpei;Shirakawa, Shinya;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1024-1029
    • /
    • 1998
  • In this paper, the voltage-fed series compensated inductor type load-resonant high-frequency inverter is originally presented for driving a newly-developed silent discharge ozone generating tube. The effective power regulation scheme of this ozonizer is proposed, which is based on PDM (Pulse Density Modulation) related PWM strategy due to DSP implementation. The effectiveness of this inverter type ozonizer is proved in simulation and experiment.

  • PDF

Changes in Oxygen-Pulse During Treadmill Walking (Treadmill 보행시 산소맥의 변화)

  • Lee, Chang-Hoon;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.281-287
    • /
    • 1984
  • In search for a method of evaluating the cardiopulmonary function. 74 male and 33 female volunteers ages $18{\sim}25$ were subjected to this study The subjects walked on a treadmill at speed of 2,4,6 and 8km/hr with 0,5,10,15,20 and 25% grade of inclination, respectively, for a measurement of heart rate and oxygen-pulse. Heart rate was measured every 5 seconds at resting state and during walking by telemetric method using Heart Checker 108 System (Senoh Co., Japan). Oxygen concentration was measured by Douglas bag method collecting expired air for 5 minutes at rest, and for 2 minutes at the end of each walking exercise. Oxygen concentration in an expired air was analyzed with Orzat gas analyser and expressed in terms of STPD. Oxygen-pulse was defined as an amount of oxygen consumed at every heart at a cellular level. The followings were the results obtained from this study. 1. Mean values of oxygen-pulse at resting state was $3.1{\pm}0.11ml/beat$ in male and $2.5{\pm}0.87ml/beat$ in female, respectively. 2. Mean values of oxygen-pulse during treadmill walking were increased in proportion with the load of exercise, namely, the speed and grade of inclination, from minimum of 7.1ml/beat upto maximum of 18.2ml/beat in male and from minimum of 4.2ml/beat upto maximum of 12,7ml/beat in female. 3. Both linear and logarithmic regressional relationships between oxygen-pulse and speed of walking and grade of inclination were observed in both sexes. Predicted values of oxygen-pulse by logarithmic regressional formula on speed and on grade of inclination were better coincided with the measured values than those predicted by the linear regressional formula.

  • PDF

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

A Study on Closed-Loop Control of a Stepping Motor for Resonance Elimination (공진배제를 위한 스템핑 모터의 폐회로제어에 관한 연구)

  • 노상현;김교형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.90-97
    • /
    • 1991
  • A stepping motor can be driven with open-loop or closed-loop control. The major disadvantage of open-loop control is that it is subjected to resonance and instability in certain speed range, and that there is no way to check stalling or error in position. In this paper, a closed-loop control system consisting of a microcomputer, a hybrid stepping motor, a drive, a lead screw, and an encoder which is used as a position sensor is developed. A control program is programmed in assembly language for real time control and the versatile interface adapter(VIA) is used as the interface with the microcomputer. The experimental results of the stepping motor were eliminated on all kinds of inertia load, and maximum start stop pulse rate and maximum slewing pulse rate were also increased about twice respectively.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

The Study on FTPM and PSPM of High Frequency Induction-Heating Iron Load (고주파유도가열 철부하의 FTPM 및 PSPM 제어에 관한 연구)

  • 임영도;김두영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.192-199
    • /
    • 2000
  • This paper describes a Phase-Shift Pulse Modulation(PSPM) and Frequency Trad이ng Pulse Modulation(FTPM) s series resonant high-frequency inverter using IGBT for the power control of high-frequency induction heating u using Neuro-Fuzzy, which is practically applied for 20kHz~500kHz induction-heating and melting power supply in i indust껴aJ fields. The adaptive frequency tracking based on the PSPM(phase-shifting pulse modulation) r regulation scherne is presented in or$\tau$ler to l11lmmlZe svvitching losses. The trially-produced breadboards using N Neuro Fuzzy controller are successfully demonstrated cUld cliscussed.

  • PDF

DESIGN AND TEST RESULTS ON A 45-KV PULSED POWER MODULATOR FOR A 1.5-MW MAGNETRON APPLICATION OF KSTAR LHCD

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Bae, Young-Soon;Cho, Moo-Hyun;NamKung, Won
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.785-792
    • /
    • 2006
  • The microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the benefits ofa reliable operation at the start of plasma formation and a non-inductive current drive durable steady state operation, respectively. LHCD uses a C-band microwave system with a frequency of 5 GHz. A pulsed power modulator with a power of 3.6 MW, $4{\mu}S$, 200 pps is required to drive the high-powered magnetron. The development of a pulse modulator with 1:4 pulse transformers is the focus of the research in this study. The peak power handling capability is 3.6 MW (45 kV, 90 A at load side with a pulse width of $4{\mu}S$). This paper describes the system overview and test results of the pulsed modulator. In particular, a simulated waveform is compared with the tested waveform.

A Study on the Development of Hybrid Micro Power Sources for the IMT2000 (IMT2000을 위한 혼성마이크로 동력원 개발에 관한 연구)

  • Kim il-Song;Youn Myung-Joong;Kim Jung-Han;Ju Hun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.203-210
    • /
    • 2005
  • A study on the hybrid micro power source for the IMT2000 application has been presented. The hybrid micro power source is composed of solar cell, super-capacitor and battery. To compensate for the pulse loader of the IMT2000 application, the super-capacitor is connected through the lithium-lon battery to absorb the pulse discharge current. The solar cell provides the additional current to compensate for the depleted current and it is controlled to operate at the maximum power point voltage. A novel maximum power point tracking method is presented to operate at the pulse discharge load conditions and verified to have superior tracking performance through experiment. The controller design for the hybrid micro power source has been presented and verified through experiment.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

EFFECT OF LOAD AND ANODE/CATHODE AREA RATIO ON WEAR OF Zr-ALLOY IN $Na_2SO_4$ SOLUTION

  • Iwabuchi, A.;Hosoya, K;Abe, K.;Shimizu, T.;Kim, S.S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.205-206
    • /
    • 2002
  • In this paper we examined the contribution of mechanical and electrochemical factors in corrosive wear for Zr-alloy against $Al_2O_3$ ball in $Na_2SO_4$ solution. Normal load and the area of metallic specimen was varied to change the corrosion behavior. At the commence of sliding, the potential drop took place, which increased with load due to the great exposure of fresh surface. Wear volume was linearly proportional to load. The corrosion factor was about 15%. By increasing the Aa/Ac ratio, corrosion factor to total wear decreases and saturates above Aa/Ac=0.15.

  • PDF