• Title/Summary/Keyword: Pulse Frequency

Search Result 1,954, Processing Time 0.033 seconds

PDM ZCS Resonant High Frequency Inverter for Induction Heated Roller

  • Kang, Shin-Chul
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents a lossless inductor snubber-assisted series resonant high frequency inverter using the trench gate IGBTs for the electromagnetic induction eddy current-heated fixing roller in copy and printing machines in a new generation. This soft switching high-frequency inverter can completely achieve zero current soft switching (ZCS) commutation mode transitions and wide power regulation under its constant frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally presented for a constant frequency PDM strategy under a ZCS operation, together with its output power regulation characteristics-based on the pulse density modulation. The effectiveness of this soft switching high-frequency inverter is confirmed for the fixing equipment with the induction-heated fixing roller.

Propagation of Partial Discharge Pulse in High Voltage Motor Stator Windings (고압전동기 고정자 권선에서 부분방전 펄스의 전송)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.512-515
    • /
    • 2003
  • This paper is to investigate how partial discharge pulse signal can flow in 6.6㎸ motor stator windings. Pulse propagation is experimentally analyzed in stator windings using a variety of frequency-domain techniques. The experiments were performed on two stator windings in the laboratory. Spectrum analyzer(9KHz to 3㎓) with tracking generator(100kHz to 3㎓) was used. Sweep time of the tracking generator was looms. The frequency spectrum of the response signal was detected by active FET probe(1㎓). The active FET probe has a flat amplitude response up to 1㎓ without high frequency attenuation. The stator winding acts as a low-pass filter below 600KHz, the high-frequency components being highly declined. The resonance peaks show about 1.1MHz and 2MHz in low frequency of No. 1 and No. 2 stator windings, respectively. This low-frequency range indicates that attenuation is low. The peaks of partial discharge magnitude show about 900MHz, 1.6MHz in No. 1 stator winding and about 800KHz, 1.4MHz in No. 2 stator winding.

Coherent Pulse Train Based Velocity Estimation and Compensation for High Resolution Range Profile of Moving Target in Stepped Frequency Radar (계단 주파수 레이더에서 이동표적의 고해상도 거리 추정을 위한 코히어런트 펄스열 기반의 속도 추정 및 보상)

  • Sim, Jae-Hun;Bae, Keun-Sung
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.309-315
    • /
    • 2018
  • A Stepped Frequency Radar(SFR) is a method of achieving high range resolution by gradually increasing the frequency of a transmitted pulse to create a wide synthetic bandwidth. However, in the case of moving target, accurate range estimation can not be performed due to the range-Doppler coupling phenomenon, so it is necessary to compensate through accurate velocity estimation. In this paper, we propose a stepped frequency radar waveform with a Coherent Pulse Train(CPT), velocity estimation results according to parameters using this method and VMD(Velocity Measurement Data) were compared and analyzed by numerical simulations.

The Study on FTPM and PSPM of High Frequency Induction-Heating Iron Load (고주파유도가열 철부하의 FTPM 및 PSPM 제어에 관한 연구)

  • 임영도;김두영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.192-199
    • /
    • 2000
  • This paper describes a Phase-Shift Pulse Modulation(PSPM) and Frequency Trad이ng Pulse Modulation(FTPM) s series resonant high-frequency inverter using IGBT for the power control of high-frequency induction heating u using Neuro-Fuzzy, which is practically applied for 20kHz~500kHz induction-heating and melting power supply in i indust껴aJ fields. The adaptive frequency tracking based on the PSPM(phase-shifting pulse modulation) r regulation scherne is presented in or$\tau$ler to l11lmmlZe svvitching losses. The trially-produced breadboards using N Neuro Fuzzy controller are successfully demonstrated cUld cliscussed.

  • PDF

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

Higher-mode effects for soil-structure systems under different components of near-fault ground motions

  • Khoshnoudian, Faramarz;Ahmadi, Ehsan;Sohrabi, Sina;Kiani, Mahdi
    • Earthquakes and Structures
    • /
    • v.7 no.1
    • /
    • pp.83-99
    • /
    • 2014
  • This study is devoted to estimate higher-mode effects for multi-story structures with considering soil-structure interaction subjected to decomposed parts of near-fault ground motions. The soil beneath the super-structure is simulated based on the Cone model concept. Two-dimensional structural models of 5, 15, and 25-story shear buildings are idealized by using nonlinear stick models. The ratio of base shears for the soil-MDOF structure system to those obtained from the equivalent soil-SDOF structure system is selected as an estimator to quantify the higher-mode effects. The results demonstrate that the trend of higher-mode effects is regular for pulse component and has a descending variation with respect to the pulse period, whereas an erratic pattern is obtained for high-frequency component. Moreover, the effect of pulse component on higher modes is more significant than high-frequency part for very short-period pulses and as the pulse period increases this phenomenon becomes vice-versa. SSI mechanism increases the higher-mode effects for both pulse and high-frequency components and slenderizing the super-structure amplifies such effects. Furthermore, for low story ductility ranges, increasing nonlinearity level leads to intensify the higher-mode effects; however, for high story ductility, such effects mitigates.

A Discrete-Amplitude Pulse Width Modulation for a High-Efficiency Linear Power Amplifier

  • Jeon, Young-Sang;Nam, Sang-Wook
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.679-688
    • /
    • 2011
  • A new discrete-amplitude pulse width modulation (DAPWM) scheme for a high-efficiency linear power amplifier is proposed. A radio frequency (RF) input signal is divided into an envelope and a phase modulated carrier. The low-frequency envelope is modulated so that it can be represented by a pulse whose area is proportional to its amplitude. The modulated pulse has at least two different pulse amplitude levels in order that the duty ratios of the pulse are kept large for small input. Then, an RF pulse train is generated by mixing the modulated envelope with the phase modulated carrier. The RF pulse train is amplified by a switching-mode power amplifier, and the original RF input signal is restored by a band pass filter. Because duty ratios of the RF pulse train are kept large in spite of a small input envelope, the DAPWM technique can reduce loss from harmonic components. Furthermore, it reduces filtering efforts required to suppress harmonic components. Simulations show that the overall efficiency of the pulsed power amplifier with DAPWM is about 60.3% for a mobile WiMax signal. This is approximately a 73% increase compared to a pulsed power amplifier with PWM.

A study of machining chracteristics effecting on laser focusing position in the ceramics microhole machining (세리믹 미세 구멍가공에서의 레이저 초점위치가 미치는 가공특성 연구)

  • Kim, Byoung-Yong;Lee, Kun-Sang
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.513-518
    • /
    • 2001
  • [ $Al_[2}O_{3}$ ] ceramics are generally used as components in processing equipment, devices or machinery. But it's difficult to machining as being machanical because $Al_[2}O_{3}$ ceramics are brittle materials. This study described a basic study of the input parameters effect on the dimension of the microhole at the $Al_[2}O_{3}$ ceramics using Nd:YAG laser. Major input parameters are peak power, pulse frequency and pulse duration in the laser microhole machining of $Al_[2}O_{3}$ ceramics. We will get a smaller microhole and diameter rate by an appropriate peak power, pulse duration.

  • PDF

Development of Vocal Signals in the Pipistrellus abramus(Chiroptera: Vespertilionidae) (집박쥐의 발성 시그널 발달에 관한 연구)

  • Chung, Chul-Un;Han, Sang-Hoon;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.2
    • /
    • pp.202-208
    • /
    • 2010
  • This study reports developmental changes in the vocal signals produced by infant or young Pipistrellus abramus. In contrast to adult bats, infant bats of the P. abramus emitted calls characterized by multi harmonics and variable signal patterns. Infants at two day of age emitted a irregular signal and showed gentle FM signals between 10 and 20 days. After about 40 days of age, the young bats emitted similar signals to the echolocation calls of adults. As the infant bats growing up, vocal signals trend showen a decrease in pulse duration(p<0.001), pulse interval(p<0.001) and number of harmonic(p<0.001). And the peak frequency(p<0.001), starting frequency(p<0.001) and ending frequency(p<0.001) in infant bats increased with the age. The largest change in pulse interval occurred in 5 days. And the pulse duration, peak frequency, starting frequency and ending frequency of the bat's sounds changed most dramatically in 25 days of age.

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF