• Title/Summary/Keyword: Pulse Frequency

Search Result 1,954, Processing Time 0.034 seconds

Development of PC based High Voltage Generator for Dental CT (PC기반 치과 CT용 고전압 펄스 발생장치 개발)

  • Kim, Hack-Seong;Oh, Jun-Yong;Song, Sang-Hoon;Won, Choong-Yeon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

A Design of ${\Delta}{\Sigma}$ Fractional-N Frequency Synthesizer Using Pulse Removed PFD for 802.11n Standard (Pulse Removed PFD를 이용한 802.11n WLAN용 ${\Delta}{\Sigma}$ Fractional-N 주파수 합성기 설계)

  • Kim, Jong-Cheol;Jeon, Boo-Won;Roh, Hyung-Hwan;Park, Jun-Seok;Oh, Ha-Ryung;Seong, Young-Rak;Joung, Myeong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1386-1388
    • /
    • 2008
  • 본 논문에서는 820.11n 규격에 적합한 Fractional-N 주파수 합성기를 설계하였다. 본 논문에서 설계한 주파수 합성기의 특징은 PFD(Phase Frequency Detector) 뒷단에 잔여 펄스를 제거하는 Pulse Remover를 연결하여 이중 궤환 Charge Pump의 안정도를 향상시켰으며, Charge Pump에서 동시에 발생하는 Up/Down 전류로 인한 Spike성 전류를 없앰으로서 스퓨리어스를 최소화 시켰다. Pulse Removed PFD를 사용함으로서 발생하는 PFD Deadzon문제는 2N+2분주와 2N-2분주기를 3차의 ${\Delta}{\Sigma}$ Modulator가 선택해줌으로 해결하였다. 삼성 0.18u 공정을 이용하여 설계 하였으며 각 블락은 Cadence spectre 를 이용하여 검증하였다.

  • PDF

A Novel Pulse Density Modulated High Frequency Inverter for Streamer Reactor (스트리머 발생을 위한 새로운 PDM 고주파 인버터)

  • Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Lee, H.W.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.223-225
    • /
    • 2005
  • This paper presents a novel prototype of a current source resonant inverter using insulated gate bipolar transistors for driving a streamer reactor, streamer generation technology has been recognized as one of the best methods for water treatment, disinfection, industrial wastes utilization, and so on. However, some technological difficulties related to efficient streamer production have been significant problems restricting streamer usage in the industrial plants. Introduced in this paper is a pulse density modulated high frequency inverter for a plasma generate, which is developed with the aim to improve power conversion and control characteristics of the streamer reactor by using advances in power electronic technology. The developed system implements the feedforward control-based pulse density modulation control scheme with pulse width modulation feedback control strategy to compensate temperature and other environmental influences on streamer discharge.

  • PDF

Effects of the Welding Parameters on the Weld Shape in Nd:YAG Laser Welding of STS 304L (STS 304L의 Nd:YAG 레이저 용접에서 용접조건이 용접부 형상에 미치는 영향)

  • 이형근;석한길;한현수;박울재;홍순복
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.58-64
    • /
    • 2004
  • The control of the weld bead shape is important in laser welding of the small parts. The effects of laser welding parameters on the weld bead shape in the pulsed Nd:YAG laser welding of STS 304L material were investigated. Shielding gas type, flow rate, pumping voltage, pulse frequency, pulse width, focal position and overlap distance were selected as laser welding parameters. Experiments were designed and conducted using the Taguchi method which was a statistical experimental method. The weld bead width, penetration, area and aspect ratio were measured and analysed as the weld bead shape properties and the welding parameters were optimized to maximize the weld aspect ratio. Weld aspect ratio were greatly affected by the pulse width, pumping voltage and pulse frequency, and somewhat by the overlap distance, and little by the shielding gas type, flow rate and focal position. A confirmation experiment were conducted using the optimized welding parameters.

Development of Pulse Diagnosis Hold-down Pressure Measurement System (맥진 가압 프로파일 측정 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Ryu, Hyun-Hee;Woo, Young-Jae;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1997-1998
    • /
    • 2008
  • Pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors. Although the pulse diagnosis position, Gwan is apart from Chon or Cheok by 10$\sim$20mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Chon, Gwan and Cheok. One the other hand, the education on pulse diagnosis behavior includes tantalizing problem caused by no tool for communication between trainer and trainee. On account of this situation, we tried to develop a system which can measure the hold-down pressure during a pulse diagnosis and compare the hold-down pressure profile of trainer and that of trainee. This system can be divided into three parts - pulse pressure sensing part, signal acquisition part and data storing part. A correction curve was generated by the relation between output voltages and standard weights. Using this system, 3 channel hold-down pressure profile of a oriental medical doctor were recorded three times. In the profile, three period were observed and all period included two process for searching the depth of pulsation and for classifying the pulse feeling into one or more of 28 pulse types. The maximum value of pulse profile was 1.3$kg{\cdot}f$ which was more than reported by previous chinese groups and the mean values of three channel ranged from 240$g{\cdot}f$ to 430$g{\cdot}f$. In frequency domain, each channel has some dominant frequency components - about 10Hz, 35Hz and 75Hz. In further study, we want to collect more profiles from lage number of oriental medicine doctors and hope to develop a measuring system which can measure the hold-down pressure on subject's skin directly.

  • PDF

Relations between 10 Primary Pulse Conditions Based on Doctors' Pulse Diagnoses (전문가 진단에 기반한 10대 맥상들 간의 연관성에 대한 연구)

  • Lee, Jae-Chul;Kang, Nam-Sik;Lee, Hae-Jung;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1077-1081
    • /
    • 2010
  • In this work, we report the diagnostic relations among some primary pulse conditions such as the floating/sunken, deficient/forceful, large/fine, and the long/short pulses. For this purpose, we carried out a clinical test, in which 11 Oriental medical doctors had participated to diagnose the pulses for 1566 healthy subjects. The subjects were divided into 11 subgroups and each subgroup was allocated to an individual doctor. It resulted in that, for 847 subjects (54%), two or more than two pulse conditions were felt simultaneously, for which we counted the frequency of the pairs of the pulse conditions. For the statistical analysis, we used a Chi-square test. As a result, at high frequency, the forceful, large, and the long pulses were diagnosed in pairs or in their triplet, and a similar close relation was found between the deficient, fine, and the short pulses. The pairwise diagnoses of the pulse conditions between the forceful, large, and the long pulses, and between the deficient, fine, and the short pulses imply their close relatedness in clinics. This result is supported by the theory of deficiency/excess syndromes. Moreover, we show that the close relatedness among the pulse conditions can be understood in terms of the geometric features of the radial artery near the prominent bone. This is the first work which reports the relatedness between the primary pulses by an objective clinical test.

Moving Artefacts Detection System for a Pulse Diagnosis System (맥진기를 위한 동잡음 검출 시스템)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.21-27
    • /
    • 2008
  • Despite recent studies on development of pulse diagnosis systems and needs for commercializing them, the reproducibility is one of the most controversial issues as ever. Because the pulse pressure value, which is one of the important parameters to evaluate reproducibility, is very vulnerable to moving artifacts, the reproducibility can not be obtained easily. In this paper, we suggested a moving artefacts detection system for a pulse diagnosis system so that a pulse diagnosis system can be robust to theses kinds of artefacts by excluding the contaminated parts from the pulse wave signal to be analyzed. This moving artifacts detection system was designed to consist of a three-axis accelerometer, an electromyography amplifier and a two-axis tilt sensor. To assess the suitability of the system, we examined the characteristics of each sensor's output signals with regard to the three specific motions such as extension, flexion and rotation. And, we also examined the each sensor's response to the high-frequency and low-frequency moving artifacts while the pulse wave signal was acquired from a pressure sensor for the pulse diagnosis. From these results, we could find that the response to subject's motions would be reflected in electromyography signal first, in accelerometer signals and in tilt sensor sequently. And, the facts that a stable pulse wave can be acquired in two seconds after high frequency or low frequency motions ended, were also found. Consequently, based on these findings, we set up some rules on the moving artifacts detection and designed an algorithm which is fit for our moving artifacts detection system.

A New DC Ripple-Voltage Suppression Scheme in Three Phase Buck Diode Rectifiers with Unity Power Factor (단위 역률을 갖는 3상 BUCK 다이오드 정류기에서의 새로운 DC 리플-전압 저감 기법)

  • Lee, Dong-Yun;Choy, Ick;Song, Joong-Ho;Choi, Ju-Yeop;Kim, Kwang-Bae;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.154-162
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output ${\gamma}$oltage in three-phase buck d diode rectifiers is presented in this paper. The proposed pulse frequency modulation method is employed to r regulate the output voltage of the buck diode rectifiers and guarantee zero-current switching of the switch over the Vvide load range. The pulse frequency control method used in tIns paper shows generally good p performance such as low THD of the input line current and unity power factor. In addition, the pulse f freιluency method can be effectively used to suppress the low frequency voltage ripple appeared in the dc output voltage. The proposed technique illustrates its validity and effectiveness through the respective s simulations and experiments.

  • PDF

Mechanical and Tribological Properties of Pulse and Direct Current Electrodeposited Ni-TiO2 Nano Composite Coatings

  • Gyawali, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Journal of Surface Science and Engineering
    • /
    • v.43 no.6
    • /
    • pp.283-288
    • /
    • 2010
  • Ni-$TiO_2$ nano composite coatings were fabricated using pulse current electrodeposition technique at 100 Hz pulse frequency with a constant 50% pulse duty cycles and reference was taken with respect to the direct current (dc) electrodeposition. The properties of the composite coatings were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. Pulse electrodeposited composite has exhibited enhancement of (111), (220), and (311) diffraction lines with an attenuation of (200) line. The results demonstrated that the microhardness of composite coatings under pulse condition was significantly improved than that of pure nickel coating as well as dc electrodeposited Ni-$TiO_2$ composite coatings. Wear tracks have shown the less plastic deformation in pulse plated composite. Coefficient of friction was also found to be lower in pulse plated composite coatings as compared to dc plated composite coatings.

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.