Impulse Electromagnetic Radition for High Voltage Nanoseconds Pulse Generator (고전압 나노초 펄스 발생기를 이용한 전자기파 방사)

  • Kim, Young-Bae;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.207-209
    • /
    • 2005
  • Ultra wide band electromagnetic energy can be transmitted to a far field by emitting the nanoseconds high voltage pulse electromagnetic energy via an antenna. This UWB EM energy is expected to be used in post-packing pasteurization of food, detection of buried objects or underground water veins and caves and the treatment of waste water or polluted gas. The nanoseconds pulse forming for UWB generation using high voltage blumlein line and an ultrafast switch is mentioned.

  • PDF

High Voltage Nanoseconds Pulse Generation for 1GW UWB radiation (GW급 UWB용 고전압 나노초 펄스 발생)

  • Kim, Young-Bae;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2123-2125
    • /
    • 2005
  • Ultra wide band electromagnetic energy can be transmitted to a far field by emitting the nanoseconds high voltage Pulse electromagnetic energy via an antenna. This UWB EM energy is expected to be used in post-packing pasteurization of food, detection of buried objects or underground water veins and caves and the treatment of waste water or polluted gas. The nanoseconds pulse forming for UWB generation using 500kV blumlein line and an ultrafast switch is mentioned.

  • PDF

Two-Dimensional Analysis Model of a Pulse Tube (맥동관의 2차원 해석모델)

  • 백상호;정은수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.157-160
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations of the gas as well as energy conservation of the tube wall. The mean temperature of the gas and the tube wall was obtained directly by assuming that the outer surface of a pulse tube is adiabatic. Effects of operating frequency, tube wall thickness, velocity ratio and velocity phase angle between both ends of a pulse tube on net enthalpy flow were shown.

  • PDF

Waveform Changes of the Radial Pulsation Followed by the Food Intakes in Healthy Subjects (식사에 따른 맥상파 변화 연구 -h1, t, 맥(脈)에너지, RAI를 중심으로-)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Gyeong-Ho;Kim, Yi-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.3
    • /
    • pp.87-96
    • /
    • 2011
  • Objectives : The study on the affected factor of the pulse wave is important in the pulse wave part. The purpose of this study is to secure the objective data of pulse-wave parameter on the food intakes affected the radial pulse-wave. Methods : The study was carried out healthy adult men. We researched the blood circulation index and the changes of the pulse factor according to 'before meal', 'right after meal', '30 minute after meal', '1 hour after meal' and '2 hours after meal'. We analyzed the changes according the time schedule. And analyzed the difference between 'before meal' and 'after meal'on the pulse-wave parameter. Results : The results were as follows. 1. HR, ECO and ECI were showed the highest increase 'after meal' and the significant decrease in '2 hours after meal' with 'before meal' degree. 2. In the pulse energy, 'left hand average pulse energy' was showed the highest increase 'after meal', and 'right hand average pulse energy' and 'right Quan(關)' were showed the highest increase in '30 minute after meal'. 3. h1 of '6 part of left and right hand'(Chon-Quan-Chuk, 寸關尺) was showed the significant difference statistically in 'left Chuk' and 'right Quan'. 4. T was showed the highest 'before meal' and the lowest after meal in '6 part of left and right' (Chon-Quan-Chuk, 寸關尺). 5. RAI was showed the highest 'before meal' in '6 part of left and right'(Chon-Quan-Chuk 寸關尺). Conclusions : From the about results, the food intakes was considered important factor of pulse formation. On the factor affected the pulse, we considered that continuous study needs for the future.

Pulse Power Supply for Laser Diode (레이저 다이오드용 펄스 전원)

  • Jin, Jeong-Tae;Cha, Byeong-Heon;Lee, Sung-Man;Chang, Dae-Sik;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.158-159
    • /
    • 2006
  • This paper shows circuits and their output characteristics of a pulse power supply for pulsed laser diodes. The power supply is designed of its output voltages over than 100 V, currents 100 A, pulse repetition rates 100 Hz, and Pulse width $10{\mu}s{\sim} 500{\mu}s$.

  • PDF

Fabrication and Operation Testing of an Air-cored Pulse Transformer for Charging a High Voltage Pulse Forming Line (고압 펄스 성형라인 충전을 위한 공심형 고압 펄스트랜스의 제작과 동작 특성)

  • Jin, Yun-Sik;Kim, Young-Bae;Kim, Jong-Soo;Ryoo, Hong-Je;Cho, Chu-Hyun;Rim, Geun-Hee;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.939-944
    • /
    • 2010
  • A high voltage air-cored helical strip/wire type pulse transformer has been fabricated for charging of a high voltage pulse forming line. As a primary coil, copper strip of 25mm width was wound helically around a MC nylon cylinder. For a secondary coil, copper enameled wire of 1mm diameter was wound around conical cylinder in order to provide insulation between two windings. The coupling coefficient of 0.53 was obtained when two coils were combined coaxially in the insulation oil filled chamber. Voltage gain and energy transfer efficiency were investigated by varying the parameters of primary and secondary circuit. Test results shows that the voltage gain increases up to 17 with increasing the primary capacitance up to 200nF. And highest energy transfer efficiency of 44% was obtained when the dual resonant operation condition was nearly satisfied. The pulse transformer developed in this study can be used for charging the middle conductor of a Blumlein pulse forming line.

A Multicoded-PPM Scheme for High Data Rate UWB Communication Systems

  • lung, Sung-Yoon;Park, Dong-Jo
    • Journal of Communications and Networks
    • /
    • v.11 no.3
    • /
    • pp.271-278
    • /
    • 2009
  • A new modulation scheme called multicoded-pulse position modulation (MC-PPM) is proposed for an ultrawideband (UWB) impulse radio communication system. The multicoded signal is generated by using several orthogonal codes for transmitting data simultaneously. Then, each multi-level value of the multicoded signal is converted to pulse position which results in not only an improved data rate, but also a processing gain in reception, delivering the power-efficient benefit of PPM and guaranteeing the low pulse energy for UWB systems. We notice that the modulation of multi-level values of the multicoded signal to pulse position is more efficient in terms of achievable data rate than the modulation of transmitting data based on other PPM schemes within given bandwidth and pulse energy. Therefore, as a performance measure, we focus on the achievable data rate (link capacity) of the proposed scheme and analyze it theoretically. Through simulation, we compare the link capacity of the MC-PPM scheme and other PPM schemes, such as M -ary PPM and multiple PPM. With the fixed bandwidth and same pulse energy condition, the UWB system based on the proposed MC-PPM scheme shows good link capacity and an increased data rate as L increases, which is contrary to other PPM schemes.

Enthalpy transport in pulse tube refrigerators (맥동관냉동기의 앤탈피이동)

  • 강영구;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.180-192
    • /
    • 1998
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube is constant. Time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass streaming and enthalpy streaming. Effects of axial temperature gradient, velocity amplitude ratio and heat transfer between the gas and the wall on the steady mass streaming and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Net Enthalpy Transport in Pulse Tube Refrigerators

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.33-44
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube was constant. The time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass and enthalpy streaming. Effects of the axial temperature gradient, velocity amplitude ratio, and heat transfer between the gas and the tube wall On the steady mass and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Nonequilibrium Heat Transfer Characteristics During Ultrafast Pulse Laser Heating of a Silicon Microstructure

  • Lee Seong Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1378-1389
    • /
    • 2005
  • This work provides the fundamental knowledge of energy transport characteristics during very short-pulse laser heating of semiconductors from a microscopic viewpoint. Based on the self-consistent hydrodynamic equations, in-situ interactions between carriers, optical phonons, and acoustic phonons are simulated to figure out energy transport mechanism during ultrafast pulse laser heating of a silicon substrate through the detailed information on the time and spatial evolutions of each temperature for carriers, longitudinal optical (LO) phonons, acoustic phonons. It is found that nonequilibrium between LO phonons and acoustic phonons should be considered for ultrafast pulse laser heating problem, two-peak structures become apparently present for the subpicosecond pulses because of the Auger heating. A substantial increase in carrier temperature is observed for lasers with a few picosecond pulse duration, whereas the temperature rise of acoustic and phonon temperatures is relatively small with decreasing laser pulse widths. A slight lagging behavior is observed due to the differences in relaxation times and heat capacities between two different phonons. Moreover, the laser fluence has a significant effect on the decaying rate of the Auger recombination.