• Title/Summary/Keyword: Pulse Energy

Search Result 1,308, Processing Time 0.035 seconds

Design and Operational Charcteristics of 150MW Pulse Modulator (150MW 펄스 MODULATOR의 설계 및 동작특성)

  • Park, S.S.;Oh, J.S.;Lee, K.T.;Kim, S.H.;Son, Y.K.;Choi, K.;Chang, S.D.;Park, S.W.;Nam, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.928-930
    • /
    • 1992
  • The design beam energy of PLS(Pohang Accelerator Laboratory) Linac is 2Gev. The linac employs total 11 units of modulators and klystrons. The maximum peak output powers of the modulators are 200MW (400kV, 500A, 4.4$\mu$S flat-top, 800$\Omega$ load) to drive the klystrons which have the peak microwave power of 80MW. Prior to the development of the 200MW modulators, a prototype 150MW modulator has been constructed and tested. We have achieved output pulses of 350kV, 420A and 3.5$\mu$S flat-top with 840$\Omega$ water load. In this article, the test results and computer simulations of charging, De-Q'ing, and discharging are presented.

  • PDF

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Spectroscopic Study of the X-ray Dip at Pre-eclipse Phase of Hercules X-1

  • Choi, C.S.;Nagase, F.;Makino, F.;Dotani, T.;Min, K.W.
    • Bulletin of the Korean Space Science Society
    • /
    • 1992.10a
    • /
    • pp.21-21
    • /
    • 1992
  • The X-ray binary pulsar Her X-1 was observed with Ginga on 1988 August 28 during the orbital phase of 0.76 to 0.85 at the main-on phase of the 35 day cycle. During the observations the X-ray intensity varied by a factor of five or more on a time scale as short as 30 sec, due mostly to the soft X-ray absorption in the pre-eclipse phase. From the studies of pulse profiles and energy spectra, we revealed that there exists in the dipphase an unpulsed component which is "3% of the intensity at the non-absorbed high-level. We suggest that scattering of the source continuum by the optically thin hot corona is responsible for the unpoised component. In the spectral analysis, we find that the high-state non-absorbed spectra can be fitted by a power-law without absorption, and the spectra observed in the different abgorption states by two components of a power-law with the same photon index. An iron-K emission line is required in to the cases of fitting. The estimated equivalent width of the iron line varies from 0.18 to 0.51 key according to the change in the absorption column density along the line of sight. We suggest that the fluorescent iron line arises in a cool and relatively small region, like the Alfvensur face, and may be partially intercepted by the optically thick gas cloud passing across the line of sight.1 Korea Astronomy Observatorya The Institute of Space and Astronautical Science in Japan3 Korea Advanced Institute of Science and Technology

  • PDF

The dynamic response and seismic damage of single-layer reticulated shells subjected to near-fault ground motions

  • Zhang, Ming;Parke, Gerry;Chang, Zhiwang
    • Earthquakes and Structures
    • /
    • v.14 no.5
    • /
    • pp.399-409
    • /
    • 2018
  • The dynamic response and seismic damage of single-layer reticulated shells in the near field of a rupturing fault can be different from those in the far field due to the different characteristics in the ground motions. To investigate the effect, the dynamic response and seismic damage of this spatial structures subjected to two different ground motions were numerically studied by nonlinear dynamic response analysis. Firstly, twelve seismic waves with an apparent velocity pulse, including horizontal and vertical seismic waves, were selected to represent the near-fault ground motion characteristics. In contrast, twelve seismic records recorded at the same site from other or same events where the epicenter was far away from the site were employed as the far-fault ground motions. Secondly, the parametric modeling process of Kiewitt single-layer reticulated domes using the finite-element package ANSYS was described carefully. Thirdly, a nonlinear time-history response analysis was carried out for typical domes subjected to different earthquakes, followed by analyzing the dynamic response and seismic damage of this spatial structures under two different ground motions based on the maximum nodal displacements and Park-Ang index as well as dissipated energy. The results showed that this spatial structures in the near field of a rupturing fault exhibit a larger dynamic response and seismic damage than those obtained from far-fault ground motions. In addition, the results also showed that the frequency overlap between structures and ground motions has a significant influence on the dynamic response of the single-layer reticulated shells, the duration of the ground motions has little effects.

Structural damage detection through longitudinal wave propagation using spectral finite element method

  • Kumar, K. Varun;Saravanan, T. Jothi;Sreekala, R.;Gopalakrishnan, N.;Mini, K.M.
    • Geomechanics and Engineering
    • /
    • v.12 no.1
    • /
    • pp.161-183
    • /
    • 2017
  • This paper investigates the damage identification of the concrete pile element through axial wave propagation technique using computational and experimental studies. Now-a-days, concrete pile foundations are often common in all engineering structures and their safety is significant for preventing the failure. Damage detection and estimation in a sub-structure is challenging as the visual picture of the sub-structure and its condition is not well known and the state of the structure or foundation can be inferred only through its static and dynamic response. The concept of wave propagation involves dynamic impedance and whenever a wave encounters a changing impedance (due to loss of stiffness), a reflecting wave is generated with the total strain energy forked as reflected as well as refracted portions. Among many frequency domain methods, the Spectral Finite Element method (SFEM) has been found suitable for analysis of wave propagation in real engineering structures as the formulation is based on dynamic equilibrium under harmonic steady state excitation. The feasibility of the axial wave propagation technique is studied through numerical simulations using Elementary rod theory and higher order Love rod theory under SFEM and ABAQUS dynamic explicit analysis with experimental validation exercise. Towards simulating the damage scenario in a pile element, dis-continuity (impedance mismatch) is induced by varying its cross-sectional area along its length. Both experimental and computational investigations are performed under pulse-echo and pitch-catch configuration methods. Analytical and experimental results are in good agreement.

Synthesis of Titanium Silicide by Electro-Discharge-Sintering of Ti and Si Powder Mixture (Ti 및 Si 혼합 분말의 전기방전소결에 의한 Titanium Silicide의 합성 연구)

  • Cheon Y. W.;Oh N. H.;Kim Y. H.;Byun C. S.;Lee S. H.;Lee W. H.
    • Journal of Powder Materials
    • /
    • v.12 no.6 s.53
    • /
    • pp.447-452
    • /
    • 2005
  • The synthesis and consolidation of titanium silicide by electro-discharge-sintering has been investigated. As-received Ti powder was in flaky shape and the mean particle size was $45.0{\mu}m$, whereas the mean particle size of the pre-milled Si powder with angular shape was $8.0{\mu}m$. Single pulse of 2.5 to 5.0 kJ/0.34g-elemental Ti and pre-milled Si powder mixture with the composition of $Ti-37.5at.\%$ Si was applied using $300{\mu}F$ capacitor. The solid with $Ti_5Si_3$ phase has been successfully fabricated by the discharge with the input energy more than 2.5kJ in less than $129{\mu}sec.$ Hv values were found to be higher than $1000kgf/mm^2$. The formation of $Ti_5Si_3$ occurred through a fast solid state diffusion reaction.

Three-staged amplifier properties of single-short pulsed distributed feedback dye laser using a XeCl laser (XeCl 레이저를 이용한 단일 단펄스 분포궤한 색소레이저의 3단 증폭기 특성)

  • 김성훈;이영우;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.424-429
    • /
    • 1999
  • The amplifier properties of single distributed feedback dye laser with 106 ps pulse width and 616 nm wavelength were invested using only one XeCl-excimer laser as pump source. For optimized amplification of DFDL, the three-stage amplifiers were arranged with increasing cross-section and accordingly increasing pump energies. The first AmpI, II stages were dye cell of 5 mm, 10 mm and contained a $6{\times}10^{-4}$ [mol/l](solvent : Methanol) of Rhodamine 610. Double-pass amplification in the AmPII was measured to suppress the ASE by using a diffraction grating. The beam intensity of AmpI, II was saturated with a gain of respectively 10 and 48. The last AmpIII was Bethune cell of 30 mm and contained a $3{\times}10^ {-4}$ [mol/l] (solvent : Ethanol) of Rhodamine 610. In the single-pass and double-pass amplification, the output energy was obtained 168.2 $\mu$J and 471$\mu$J respectively.

  • PDF

TID and SEGR Testing on MOSFET of DC/DC Power Buck Converter (DC/DC 강압컨버터용 MOSFET의 TID 및 SEGR 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.981-987
    • /
    • 2014
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a MOSFET (metal-oxide semiconductor field effect transistor), a PWM-IC (pulse width modulation-integrated circuit) controller, inductor, capacitor, etc. It is shown that the variation of threshold voltage and the breakdown voltage in the electrical characteristics of MOSFET occurs by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 5 heavy ions make the gate of MOSFET broken in SEGR (Single Event Gate Rupture) testing. TID testing on MOSFET is accomplished up to the total dose of 40 krad, and the cross section($cm^2$) versus LET(MeV/mg/$cm^2$) in the MOSFET operation is studied at SEGR testing after implementation of the controller board.

The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions (구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

Fault Diagnosis of Solar Power Inverter Using Characteristics of Trajectory Image of Current And Tree Model (전류 궤적 영상의 특징과 트리모델을 이용한 태양광 전력 인버터의 고장진단)

  • Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • The photovoltaic system changes solar energy into DC by solar cell and this DC is inverted into AC which is used in general houses by inverter. Recently, the use of power of the photovoltaic system is increased. Therefore, the study of 3 phase solar system to transmit large power is very important. This paper proposes a method that finds simply faults and diagnoses the switch open faults of 3-phase pulse width modulation (PWM) inverter of grid-connected photovoltaic system. The proposed method in $\alpha\beta$ plane uses the patterns of trajectory image as the characteristic parameters and differenciates a normal state and open states of switches. Then, the result is made into tree. The tree is composed of 21 fault patterns and the parameters to classify faults are a shape, a trajectory area, a distributed angle, and a typical vector angle. The result shows that the proposed method diagnosed fault diagnoses, classified correctly them, and made a pattern tree by fault patterns.