• 제목/요약/키워드: Pulse Echo

검색결과 312건 처리시간 0.033초

T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence

  • E-K. Jeong;Lee, S-H.;J-S. Suh;Y-Y wak;S-A. Shin;Y-K. Kwon;Y. Huh
    • 한국자기공명학회논문지
    • /
    • 제1권1호
    • /
    • pp.7-20
    • /
    • 1997
  • The mapping of the spin-spin relaxation time T2 in pixed-by-pixel was suggested as a quantitative diagnostic tool in medicine. Although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any misregistration of each pixel's signal for the fitting T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17∼20 msec can give the reliable T2 map.

  • PDF

악관절에 대한 자기 공명 영상의 연구 (A STUDY ON MAGNETIC RESONANCE IMAGING OF THE TEMPOROMANDIBULAR JOINT)

  • 김형식;김재덕
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.187-198
    • /
    • 1990
  • Examinations of the temporomandibular joints were performed on a 1.5 Tesla magnetic resonance (MR) system. An MR surface receiver coil 3 inch in diameter was placed on plastic frame, the patient's head being placed in the frame so that the coil was pressed against the temporal region. In taking advantage of the magnetic resonance imaging that has been studied briskly till now, author obtained the images of parasagittal and paracoronal planes about the temporomandibular joint by using MPGR (Multi-Planar Gradient Recalled), GRASS (Gradient Recalled Acquisition in the Steady State), and CSMEMP (Contiguous Slice Multiple Echo, Multi-Planar), that differ from the Spin Echo pulse sequence which the previous authors used. Five subjects with no symptoms of temporomandibular joint pain and dysfunction were studied. The plane images obtained by these methods were compared with those by Spin Echo pulse sequence. The results were as follows: 1. The optimal repetition times (TR) and echo times (TE) for T.M.J. image were; a. 400 msec and 18 msec in PMGR pulse sequence. b. 40 msec and 12 msec in GRASS pulse sequence. c. 700 msec and 30 msec in CSMEMP pulse sequence. d. 500 msec and 20 msec in Spin Echo pulse sequence. 2. When the MPGR pulse sequence was using, T2-weighted image was obtained in very short time. On the image of the paracoronal plane by GRASS pulse sequence, meniscus showed the moderate signal intensity, and the meniscus and its anteromedial, posterolateral attachments were observed definitely with gray color. 4. The signal intensity of Spin Echo pulse sequence was equal to that of CSMEMP pulse sequence, but the image by CSMEMP pulse sequence showed relatively lower level in its resolution.

  • PDF

초음파 펄스 에코 패턴으로 용접 결함 식별 방법 연구 (Study of the Weld Defects Identification Method by Ultrasonic Pulse Echo Patterns)

  • 김원중
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6114-6118
    • /
    • 2013
  • 본 연구에서는 초음파 탐상시험의 펄스 반사법으로 각각 용접결함에 따른 초음파 펄스파형모형을 연구하였다. 균열은 예리하고 선명한 신호들을 발생한다. 탐촉자를 결함주위로 이동하면 에코높이는 변한다. 긴 균열에서는 탐촉자가 결함 주위를 원형으로 목돌림주사법을 사용하여 탐상하면 에코높이는 급격히 감소한다. 그 에코 봉우리는 바늘과 같이 얇고 날카롭다. 기공은 단일 결함으로부터 발생하는 에코는 예리하고 선명하다 하지만 집단의 기공들은 다수의 반사들이 중첩되고 트레이스가 들쭉날쭉한 에코가 발생한다. 슬래그 개재물은 크랙과 슬래그 결함위치에서 각각 목돌림 주사법을 사용하여 탐상하면 그 에코형상은 어느 정도 차이를 볼 수 있었다. crack은 그 에코높이가 급격히 변하는 반면에 슬래그 개재물은 증가${\rightarrow}$감소${\rightarrow}$증가${\rightarrow}$감소된다. 또한 다수 밀집된 기공의 위치에서 결함은 대표적 에코형상과 같은 잡다한 에코형상은 슬래그에서는 볼 수 없었다. 용입불량은 결함의 에코형상은 크랙과 같이 날카롭고 예리하게 나타났고, crack과 비슷한 에코형상은 갖고 있었다.

The Method of Reducing Echo Time in 3D Time-of-flight Angiography

  • Park, Sung-Hong;Park, Jung-Il;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.367-369
    • /
    • 2002
  • We have designed ramp profile excitation pulse based on the Shinnar-Le Roux (SLR) algorithm. The algorithm provides many advantages to pulse designers. The first advantage is the freedom of deciding the amplitudes, frequencies, and ripple sizes of stopband, passband, and transition band of pulse profile. The second advantage is the freedom of deciding the pulse phase, more specifically, minimum phase, linear phase, maximum phase, and any phase between them. The minimum phase pulse is the best choice in the case of 3D TOF, because it minimizes the echo time, which implies the best image quality in the same MR examination condition. In addition, the half echo technique is slightly modified in our case. In general, using the half echo technique means that the acquired data size is half and the rest part can be filled with complex conjugate of acquired data. But in our case, the echo center is just shifted to left, which implies the reduction of echo time, and the acquired data size is the same as the one without using the half echo technique. In this case, the increase of right part of data leads to improvement of the resolution and the decrease of left part of data leads to decrease of signal to noise ratio. Since in the case of 3D TOF, the signal to noise ratio is sufficiently high and the resolution is more important than signal to noise ratio, the proposed method appears to be significantly affective and gives rise to the improved high resolution angiograms.

  • PDF

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

이종재 막찰용접 이음부에서의 초음파 반사계수와 용접조건과의 관계 (The Relationship between Welding Conditions and Ultrasonic Reflection Coefficients of Dissimilar Metals Friction Welded Joints)

  • 오세규;김동조;한상덕
    • 한국해양공학회지
    • /
    • 제1권1호
    • /
    • pp.138-143
    • /
    • 1987
  • Friction welding has emerged as a reliable process for high-production commercial applications with significant economic and technical advantages. But nondestructive test in friction weld was not clearly developed. Therefore the experimental verification is necessary in order to understand the characteristcs of the pulse echo effects according to various change in welding conditions. This paper presents an attempt to determine the relationship between the varios welding conditions and the coefficients of reflection using the ultrasonic pulse echo method in dissibilar metals friction weld. The new approach of calculating the coefficients of reflection based on measured amplitudes of the echoes is applied in this paper. These coefficients provides a single quantitative measurement which involves both acoustic energy reflected at the welded interface as well as transmitted across the interface. As a result, it was known that the quantitave relationship between welding conditions and the coefficients of reflection using the ultrasonic pulse echo exists in dissimilar metals friction weld.

  • PDF

자기공명영상에서의 스핀 시각화 (Spin Visualization for Magnetic Resonance Imaging)

  • 조상흠;강승원;전수열;임헌진;김판기;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2153-2154
    • /
    • 2006
  • MR imaging에서 RF pulse에 의한 Spin들의 이동과 dephase, rephase 되는 모양을 Spin visualization을 사용하면 직관적으로 이해할 수 있다. 다양한 각도의 RF pulse 가 여러 번 가해지면, spin echo 외에도 stimulated echo, "eight-ball" echo 등이 나타나기 때문에 직관적으로 echo들을 이해하기가 어려워진다. Spin에 RF pulse가 가해졌을 때, 기존의 2차원의 Profile로 spin들의 상태를 보는 것보다 3차원 공간상에서 spin들의 상태를 살펴봄으로써, 좀 더 쉽게 MR 신호를 이해할 수 있다. 특히 고자장에서 SAR 문제 때문에 낮은 각도의 RF pulse 를 사용하여 영상을 해야 하기 때문에 spin visualization은 새로운 영상 방법을 이해하거나 디자인하는데 중요하다.

  • PDF

초음파 Pulse-echo 방법에 의한 액체막 두께 측정 (Liquid Film Thickness Measurement by An Ultrasonic Pulse Echo Method)

  • Jong Ryul Park;Jong-Ryul Park;Se Kyung Lee
    • Nuclear Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.25-33
    • /
    • 1985
  • 경수형 원자로의 운전과 안전성 해석을 위해 열수력학적 모형을 개발하는 것이 하나의 중요한 과제이다. 특히, 2상류의 열수력학적 모형을 개발하기 위해서는 기포율, 액체막 두께, 유동 영역과 같은 중요한 변수들을 실제로 측정한 값이 필요하다. 본 연구의 목적은 초음파 Pulse-echo 방법을 이용하여 액체 두께를 실험적으로 측정하고, 이론치와 비교 분석하여 (1) 관벽의 두께, (2) 초음파의 주파수, (3) 관벽의 재질 등이 액체막 두께 측정에 미치는 영향을 분석하는 데에 있다. 평판협 (Plate-type)과 관(Tube-type)으로 된 시험관을 이용하여 수평으로 놓인 물-공기의 층류계 (a horizontal airwater stratified system)를 만들어 일련의 액체막 두께 측정 실험을 수행하였다. 시험관의 벽 두께와 초음파 Pulse-echo 의 주파수를 변화시키면서 액체막 두께 측정을 반복하였다. 또한, 관벽의 acoustic impedance가 초음파 Pulse-echo 방법으로 액체막 두께를 측정할 때, 어떠한 영향을 주는가도 아울러 파악하기 위해서 스텐레스 강과 폴리아크릴 (Polyacrylate) 등 재질이 다른 두 개의 격리봉 (Standonff rod) 을 사용하여 액체막 두께를 측정하였다. 이렇게 하여 얻은 실험 결과를 제시하고 실제로 측정한 액체막 두께와 비교 분석하였다.

  • PDF

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구 (A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.253-259
    • /
    • 2015
  • 본 연구에서는 가돌리늄 조영제를 다양한 몰농도로 희석하여 T1 효과를 나타내는 펄스 시퀀스 중 고속스핀에코와 에코타임이 극도로 짧은 ultra short time echo에서 최대 신호 강도 분포를 나타내는 조영제 희석 몰농도를 3.0T에서 각각 알아보고자 하였다. T1 조영제인 gadoxetic acid 와 완충용액으로는 증류수, 2% agarose gel을 이용하여 다양한 몰농도로 조영제 팬텀을 제작하였다. 팬텀 제작의 정확성을 측정하기 위해 T1 이완시간 측정의 표준방식인 2D inversion recovery spine-echo 펄스시퀀스를 이용하였으며 팬텀의 중간 부의 한 개의 관상면 영상을 획득하여 T1 이완 시간을 계산하였다. 스핀에코에서는 1-2 mmol/L 조영제 몰농도에서 가장 높은 신호를 나타냈으며, ultra short time echo에서는 7 mmol/L에서 가장 큰 신호를 나타냈다. ultra short time echo 펄스 시퀀스를 이용한 조영증강 효과를 보기 위해서는 고속스핀에코 기법 보다 2-3배의 조영제 농도가 목적 장기에 유지하여야 하며 이와 관련된 조영제량 및 투여 방법의 연구가 이루어져야 한다.

PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성 (Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite)

  • 박정학;최헌일;손무현;사공건
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권10호
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF