• Title/Summary/Keyword: Pulse Duration

Search Result 511, Processing Time 0.032 seconds

A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method (Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성)

  • Joung, Jong-Han;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

Weldability of Dissimilar Metal Plates with YAG Laser (YAG 레이저에 의한 이종금속판재의 접합특성)

  • 이지환
    • Journal of Welding and Joining
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 1988
  • This paper describes weldability of dissimilar metal plates with YAG laser for the use of a small-size electronic spring parts. Effects of welding conditions, combination of plates, thickness of upper plate are examined in relation to welding strength and microstructure of welded region. The obtained results are summarized as follows. Welding defects such as cavity and crack showed a tendency to easily occur in the case where 1) pulse duration is short, 2) laser power is high, 3) PBS plate with high thermal diffusivity is used for lower plate. Among these defects, the occurrence of cavity cased a drop of welding strength. This results from the reduction of welding area between upper and lower plates. In SK-5/SUS304 plates (thickness: 0.2/0.4mm/, welding strength was the highest in welding conditions: laser power is 30J/pulse, pulse duration 9ms, amount of defocus +2mm.

  • PDF

Using Pulse-Front Tilt to Measure Laser Pulses Less Than 100 Picoseconds in Duration

  • Jeong, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.318-321
    • /
    • 2015
  • We demonstrate a frequency-resolved optical grating (FROG) device for measuring the intensity and phase versus time of several-tens-of-picoseconds laser pulses, using a thick nonlinear optical crystal. The huge pulse-front tilt generated by a holographic grating increases the temporal range of the device, which can make a single-shot measurement of laser pulses less than 100 ps in duration. To verify the measurement technique, we generate double pulses using a Michelson interferometer. The measured duration of a single pulse is about 300 fs and the measured maximum delay of two pulses is 60 ps, which implies that the proposed FROG device can measure laser pulses with maximum pulse width of about 120 ps.

Characterization of sounds produced by 3 sciaenid species (민어과 어류의 명음에 관한 음향학적 특성)

  • Lee, Kyoung-Hoon;Yang, Yong-Soo;Kim, Jin-Ku;An, Heui-Chun;Shin, Jong-Keun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.3
    • /
    • pp.206-211
    • /
    • 2007
  • The sciaenid species, which has swimbladder, generates sounds by vibrating in its length wards when spawning or getting stimulus from something else. This research analyzed on sound frequency characteristics relatives to their swimbladder length of three sciaenid species, yellow croaker(Larimichthys polyactis), brown croaker(Miichthys miiuy), and white flower croaker(Nibea albiflora). As results, the dominant frequency for yellow croaker ranged over 38.08 to 141.60Hz in wide frequency band, and the averaged pulse duration expressed in $280.3{\pm}156.0ms$. For brown croaker, the dominant frequency ranged in 49.80 to 59.57Hz, and the averaged pulse duration was $129.1{\pm}36.9ms$. Moreover, the dominant frequency of white flower croaker ranged in 73.24 to 86.91Hz, and the averaged pulse duration was $88.0{\pm}15.9ms$, it has shorter pulse duration than any two species. Therefore, the dominant frequency relatives to swimbladder length of sciaenidae showed that it had widely resonant characteristics and long pulse duration as in shorter swimbladder length. Additionally, for white flower croaker, we could confirm their behavior and sounds in response to production of recorded sounds using underwater speaker.

Detection and interpretation of wan-maeck by the pulse diagnostic apparatus -on the pulse/respiration rate- (완맥(緩脈)의 동서의학적(東西醫學的) 해석 -맥율(脈率)을 중심으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Kim, Yong-Suk;Lee, Yun-Ho;Kim, Sung-Woon;Huh, Wung;Youn, Chung-Hwa
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.143-156
    • /
    • 1997
  • This report was conducted to quantify the pulse/respiration ratio and set up the normal range of wan-maeck(緩脈). In order to objectify the pulse diagnosis and use as basic clinical index of Cold-Hot diagnosis, we developed the hardware and software for detection and interpretation of pulse/respiration ratio, pulse/expiration ratio, pulse/respiration ratio, inspiration time, expiration time, respiration frequency, respiration time, duration of one pulse and pulse and pulse rate per minute, The results were as follows; pulse/respiration ratio is $4.30{\pm}1.03$ times, pulse/respiration ratio is $1.60{\pm}0.32$ times, pulse/respiration ratio is $2.37{\pm}0.75$ times, inspiration time is $1.35{\pm}0.20$ sec, expiration time is $1.89{\pm}0.39$ sec, respiration frequency is $17.16{\pm}3.49$ times/min, total respiration time is $3.63{\pm}0.71$ sec, duration of a pulse is $0.86{\pm}0.15$ sec, pulse rate is $71.51{\pm}12.30$ times/min.

  • PDF

The Call Patterns and the Change of Calls by Water Temperature in Rana plancyi (Amphibia, Anura) (금개구리(Rana plancyi)의 소리 유형과 수온에 따른 소리변화)

  • 박시룡;이병근;양서영
    • The Korean Journal of Ecology
    • /
    • v.21 no.3
    • /
    • pp.269-276
    • /
    • 1998
  • The study of the Rana plancyi, was done during the calling period at a pond in Osong, Chungbuk, Korea from May to the middle of August of 1996 and 1997. Five basic types of call-A, B, C, D, E, - were identified in Rana plancyi according to the structure of call types. The structure of A type call has only one pulse, B type call has two pulses and C, D type call has one separated pulse which is called introductory call and pulse group as follow it. On the other hand, E type call has 3-6 separate pulses. The interval between introductory call and pulse group is $0.73{\pm}0.29$ s(n=159) in C type call and $0.60{\pm}0.21$ s (n=48) in D type call. The number of pulses in the pulse group is $30.08{\pm}8.69$ in C type call and $15.78{\pm}2.40$ in D type call. An increase in water temperature induces a decrease in C and D type call duration (C type call r= -0.4153, p<0.001, D type call r=-0.7064, p<0.001). In case of C and D type call, the interval between introductory call and pulse group influenced more call duration than pulse group duration. We regarded A, B type call as a territorial call and C, D type call as a mating call and we recognized that E type call has the function of threat or alarm.

  • PDF

The Impulse Output Characteristics using Cascading Method of Compact Transformer (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Joung, Jong-Han;Kim, Whi-Young;Hong, Jung-Hwan;Park, Koo-Ryul;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

Design of a Femtosecond Ti:sapphire Laser for Generation and Temporal Optimization of 0.5-PW Laser Pulses at a 0.1-Hz Repetition Rate

  • Sung, Jae-Hee;Yu, Tae-Jun;Lee, Seong-Ku;Jeong, Tae-Moon;Choi, Il-Woo;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • A chirped-pulse amplification Ti:sapphire laser system has been designed using a 10-Hz 100-TW Ti:sapphire laser to generate 0.1-Hz 0.5-PW laser pulses and optimize their temporal qualities such as temporal contrast and pulse duration. A high-energy booster amplifier to be added is expected to produce an energy above 30 J through the parasitic lasing suppression and the efficient amplification. To improve the temporal contrast of the laser pulses, a high-contrast 1-kHz amplifier system is used as a front-end. A grating stretcher which makes the laser pulse have 1-ns duration is used to prevent optical damages due to high pulse energy during amplification. A grating compressor has been designed with group delay analysis to obtain the recompressed pulse duration close to the transform-limited pulse duration. The final laser pulses are expected to have energy above 20 J and duration below 40 fs.

Optimal condition for efficient DNA transfer in filamentous cyanobacteria by electroporation

  • Poo, Ha-Ryoung
    • Journal of Microbiology
    • /
    • v.35 no.3
    • /
    • pp.181-187
    • /
    • 1997
  • Filamentous cyanobacteria are an ecologically important group of bacteria because they are able to provide both organic carbon fixed nitrogen that can support the nutritional requirements for other microorganisms. Because of their prokaryotic nature, they can also be used as potentially powerful model systems for the analysis of oxygenic photosynthesis and nitrogen fixation. Gene transfer is an indispensable procedure for genetic analysis of filamentous cyanobacteria. Electroporation was used to introduce foreign DNA into cyanobacterial cells. In experiments designed to optimize the electroporation technique, the effects of the field strength (amplitude of pulse) and time constant (duration of pulse), DNA concentration and host restriction/modification of DNA on the efficiency of electro-transformation were investigated. The results of this research revelaed that a high voltage pulse of short duration was effective for the electro-transformation of Anabaene sp. M131. The maximal number of transformants was obtained at 6 kV/cm with a pulse duration of 5 msec. The efficiency of electro-transformation was also sensitive to concenetration of DNA; even small amounts of DNA (0.01 .mu.g/ml) were able to gie a large number of transformants (1.0 * 10$\^$3/ cfu/ml).

  • PDF