• Title/Summary/Keyword: Pulse Control

Search Result 2,244, Processing Time 0.029 seconds

${\ll}$황제내경(黃帝內經)${\gg}$ 의 심(心)의 개념(槪念)과 장상(藏象)에 대한 연구(硏究)

  • Lee Yong-Beom;Bang Jeong-Gyun
    • Journal of Korean Medical classics
    • /
    • v.13 no.1
    • /
    • pp.269-303
    • /
    • 2000
  • The xin(心) has various meanings in ${\ll}$Huangdineijing(黃帝內經)${\gg}$ but they sometimes contradict each other. This thesis divided the xin into the meaning and the Zang-xiang(藏象), and then analyzed the xin's notion in detail. The concept of the xin in ${\ll}$Huangdineijing(黃帝內經)${\gg}$ is sorted out into : the notion of space, yin-yang five elements(陰陽五行) and shen(神) The xin is the upper part of body and it possesses the character of yang(陽). So the concept of the breast has originated from this character and it rightly belonged to the top. The xin is assigned to fire among five elements, 'chang(長)', which has the energy of moving forward, noon at a day when yang-qi(陽氣) is properous and shows 'gu(鉤)' & 'keo(矩)' in pulse condition. The xin possesses the character, 'Taiyang of the yang(陽中之太陽)' along with the notion of space combined with five elements. That is, the notion of upper space means 'of the yang(陽中)', and, fire in five elements means 'yang'. This is similar to '=(Taiyang)' of Sasang(四象) at ${\ll}$the Book of Changes(周易)${\gg}$ Since the xin puts shen(神) in order, actions of spirit have effect on the xin. And it depends whether the sense of vitality is broad or narrow. The xin related with broad sense of spirit is 'monarch of the organs(君主之官)'. Therefore it has control over the human body. As it also directly effects the life or death, Pericardium(心句) substitutes the xin and protects the external invasion. In Shi-er-won(十二原) and Bonsu(本輸), instead of the Xin Channel the Pericardium Channel was used in healing patients. The xin can be interpretable as the mind, because the xin includes spirit. The mind can be distinguished into 'desire' and 'state of profound reason'. In ${\ll}$Huangdineijing(黃帝內徑)${\gg}$, the disease of the xin caused by emotion was mentioned many times. This emotion is 'desire' which resorted to the sentiment. The reason one mind has both character is; man preserves given principle (reason) and emotion reveals via the reason exercised. The above is about the xin related with the broad sense of vitality. Concerning the narrow sense of vitality, one of the five vitalities is stored with the others away in the five solid organs. Then it takes part in the operation of five body constituents and it is linked with the personified description of five solid organs. The xin, spleen, stomach and kidney are 'the ground of life'. Spleen and stomach are the origin of making qi and blood, which 'means the ground after birth'. Kidney keeps the essence of life, and manages the growing and generative function of human body. The xin keeps 'Shin-myung(神明)', in other words, it has control over and supervise whole activity of body. Therefore xin's role is needed for the appropriate working of spleen, stomach and kidney. And 'Shin-myung' is its motive power. In ${\ll}$Huangdineijing(黃帝內經)${\gg}$, the reason why xin was assigned to September and October is that yang-qi of the human body goes to the inner part, with xin at the same time. This explains that yang-qi of the human body is adapted to change of season and goes into xin-fire(心火) in order to get away from the cold. In this case, heart means more inner part than liver, spleen and lung. Mengzi(孟子), philosopher of the China's turbulent ages emphasized the thinking function of xin. Sunzi(荀子) asserted that xin is 'heaven monarch(天君)' and the other organs are 'heaven rninisters(天官)'. This conception is similar to 'monarch of the organs' of ${\ll}$Huangdineijing(黃帝內經)${\gg}$. After the Ming Dynasty, commentators of Huangdineijing(黃帝內經) explained the heart, as 'monarch of the organs', or 'the master of body(一身之主)'. This was due to the influence of Sung Confucianism.

  • PDF

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

$^{17}O$ NMR Study On Water Excharge Rate of Paramagnetic Contrast Agents ($^{17}O$ NMR 기법을 이용한 상자성 자기공명조영제의 물분자 교환에 관한 연구)

  • Yongmin Chang;Sung Wook Hong;Moon Jung Hwang;Il Soo Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Purpose : The water exchange rate between bulk water and bound water is an important parameter in deciding the efficiency of paramagnetic contrast agents. In this study, we evaluated the water exchange rates of various Gd-chelates using oxygen-17 NMR technique. Material and Methods : The samples (Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, Gd-EOB-DTPA) were prepared by mixing 5% $^{17}O-enriched$ water (Isotech, USA). The pH of the samples was adjusted to physiological value [pH=7.0] by buffer solution. The variable temperature $^{17}O-NMR$ measurements were performed using Bruker-600 (14.1 T, 81.3 MHz) spectrometer. Bruker VT-1000 temperature control units were used to stabilize the temperature. The $^{17}O$ spin-spin relaxation times (T2) were measured using Carr-Purcell-Meiboom-Gill (CPMG)I pulse sequence with 24 echo trains. The variable temperature T2 relaxation data were then fitted into Solomon-Bloembergen equations using least square fit algorithm to estimate the water exchange times. Results : From the measured $^{17}O-NMR$ relaxation rates, the determined water exchange rates at 300K are $0.42{\;}{\mu}s$ for Gd-DTPA, $1.99{\;}{\mu}s$ for Gd-DTPA-BMA, $0.27{\;}{\mu}s$ for Gd-DOTA, and $0.11{\;}{\mu}s$ for Gd-EOB-DTPA. The Gd-DTPA-BMA showed slowest exchange whereas Gd-EOB-DTPA had fastest water exchange rate. In addition, it was found that the water exchange rates (${\tau}_m$) of all samples had exponential temperature dependence with different decay constant. Conclusion : $^{17}O-NMR$ relaxation rate measurements, when combined with variable temperature technique, provide a solid tool for studying water exchange rate, which is very important in investigating the detailed mechanism of relaxation enhancement effect of the paramagnetic contrast agents.

  • PDF

Development and Expression of Porcine Embryos by Direct Injection of Sperm Treated with Exogenous DNA (외래유전자 도입정자를 이용한 돼지 체외성숙 난포란의 Intracytoplasmic Sperm Injection (ICSI) 후 후기 배로의 발달율과 외래유전자의 발현에 관한 연구)

  • 정기화;조성근
    • Journal of Embryo Transfer
    • /
    • v.17 no.1
    • /
    • pp.45-53
    • /
    • 2002
  • The main goal of this study was to produce transgenic porcine embryos by direct injection of sperm-mediated exogenous DNA. Spermatozoa (6$\times$10$^{6}$ sperms of final concentration) were mixed with pcDNA LAC Z (20 ng/$\mu$l) and subjected into electroporation (300~750 volts, 25 $\mu$F, 0.4 cm electrode). After sperm injection, the oocytes were activated electrically (1.7 KV/cm, 30$\mu$sec, single pulse) in 0.3 M mannitol solution or not. The sperm injected eggs were cultured in NCSU 23 medium (0.4% BSA) at 39$^{\circ}C$, 5% $CO_2$ in air fur 144 h. The rates of cleavage and development into blastocyst stage in activation group were significantly higher than those of non-activation group (79.6% and 24.1% vs. 46.3% and 14.4%, respectively, p<0.05). Control oocytes and shame injection were developed to blastocysts low (2.5%). Sixty five (27.1%) out of 240 embryos observed in activation and non-activation groups were showed positive by X-gal staining. However, all embryos in both groups were expressed partial or mosaic pattern. These results suggested that electrical stimulation far oocytes activation after sperm injection enhances the incidence of both fertilization and development fellowing sperm injection in the pig. Our study also suggested that sperm-mediated transfer of exogenous DNA by ICSI would be used as a valuable tool for the production of transgenic porcine embryos.

Epidemic acute interstitial pneumonia in children occurred during the early 2006s (2006년 초에 유행한 소아 급성 간질성폐렴)

  • Cheon, Chong Kun;Jin, Hyun-Seung;Kang, Eun Kyeong;Kim, Hyo Bin;Kim, Byoung-Joo;Yu, Jinho;Park, Seong Jong;Hong, Soo-Jong;Park, June Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.383-390
    • /
    • 2008
  • Purpose : This study was aimed to analyze the clinical characteristics of patients with acute interstitial pneumonia who had presented similar clinical patterns from March to June, 2006 and to describe our experience of treatment and to identify risk factors associated with prognosis. Methods : The clinical characteristics, radiologic and histopathologic findings and response to steroids of 15 patients (non-survival group [n=7] and survival group [control, n=8]) with acute interstitial pneumonia were investigated through the review of medical records. Results : The mean age of the patients was 26 (range: 3-48) months. Cough, cyanosis and fever were frequent symptoms. The most frequent radiologic findings on admission were pneumomediastium and extensive ground glass opacity. Surgical lung biopsy was performed on 8/15 (53.3%) patients and diffuse alveolar damage was found. Mechanical ventilation was applied for 9/15 (60.0%) patients for 40 (range: 1-99) days. Five patients in survival group received steroid treatment and 7 patients in non-survivial group (P=0.20). One patient in survival group received steroid pulse treatment and 4 patients in non-survival group (P=0.12). Seven patients died all of respiratory failure. The survival rate was 53.4%. Conclusion : The patients with acute interstitial pneumonia which occurred on spring 2006 showed high mortality because of rapidly and extensively progressing pulmonary fibrosis and air leakage. Therefore, we should consider surgical lung biopsy and steroid application earlier. We should recognize this acute interstitial pneumonia occurring on spring in domestics and need to investigate the cause and treatment in large scale.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

The Effect of Midazolam As Sedative Agent in Bronchoscopy (기관지내시경 검사시 전처치로서 Midazolam의 효과)

  • Lee, Sang-Haak;Hyun, Dae-Sing;Lee, Sook-Young;Kim, Seok-Chan;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.612-618
    • /
    • 2002
  • Background : Bronchoscopy is an important diagnostic and a therapeutic tool in chest medicine. However, most patients feel that a bronchoscopy is an unpleasant procedure, and it is important to sedate the patients appropriately, particularly where repetitive examinations are required. Midazolam is a sedative drug with amnestic qualities and a rapid 2 hour half-life. This study have attempted to determine the safety, appropriate dosage, and the effect of midazolam premedication in patients who underwent a bronchoscopy. Methods : One hundred and eighty consecutive patients undergoing bronchoscopy were enrolled in this study. The patients received a midzolam doses of 0.03 mg/kg, 0.06 mg/kg, or a placebo. An additional dose of lidocaine, the total number of coughs, and the duration of the procedures were recorded with monitoring the the blood pressure, heart rate, and oxygen saturation. The level of satisfaction was assessed by the patient, bronchoscopist, and the nurse. Results : The blood pressure, pulse rates, oxygen saturation, number of coughs, lidocaine dose, and procedure time in the 3 groups were similar. There was a trend for the midazolam 0.03 mg/kg group to satisfy bronchoscopists more than the other two groups. The nurses' acceptability was lower in the midazolam 0.06 mg/kg group than the other groups. The patients' acceptablity was greater in both the midazolam 0.03 mg/kg and 0.06 mg/kg groups than in the control group. Conclusion : Sedation with low doses of intravenous midazolam is a safe technique for fiberoptic bronchoscopy with a low morbidity and high acceptable to patients and bronchoscopists.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

The Effect of Aroma Therapy on Lower Extremity Edema of Terminal Cancer Patients: A Controlled Trial (아로마 요법이 말기 암 환자의 하지부종에 미치는 영향 - 대조군 연구)

  • Kim, Sung-Ah;Kim, Sung-Ju;Chung, Ju-Hye;Lee, Soo-Young;Han, Myung-Suk;Oh, Seon-Hee;Kim, Se-Hong
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.3
    • /
    • pp.139-146
    • /
    • 2009
  • This study was designed to examine the effect of aroma massage therapy on lower extremity edema of terminal cancer patients. Methods: A total of thirty-six terminal cancer patients with lower extremity edema were divided into two groups: the aroma massage group received massage with blending oil which was applied from toes to 10 cm above the knee of the subject for 15 to 20 minutes in each turn, while the control group received sham aroma massage (applied with carrier oil only). The circumferences of the fore-foot, ankle and calf were measured before massage and 30 minutes, 2 hours, and 12 hours after massage. The blood pressure, pulse and body temperature were also measured to find the change of subject's physiologic conditions. Results: There were no significant differences in blood pressure, heart rate, body temperature and lower extremity circumferences between two groups. However, edema at each site was slightly improved in the treatment group after the aroma massage therapy, compared to baseline data (P<0.05). In addition, the reduction of lower extremity circumference was maximal at 2 hours in foot, 30 min in right ankle and 12 hours in right calf after aroma massage therapy (P<0.05). Conclusion: Our results suggest that aroma massage therapy is not effective on the lower extremity edema of terminal cancer patients.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.