• Title/Summary/Keyword: Pulse Control

Search Result 2,246, Processing Time 0.027 seconds

Comparison of Electrodermal Activity between Hypertensive and Non-hypertensive Subject in Health Screening Population (건강검진자 대상 고혈압 유무에 따른 피부전기활동성 비교 연구)

  • Kim, Young Eun;Kim, Chul;Yea, Sang Jun;Yang, Chang Sop;Song, Mi Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.847-852
    • /
    • 2013
  • The aim of this study was to investigate the difference of electrodermal activity between the hypertensive and non-hypertensive subjects. A total 161 subjects who visited a hospital for health check ups from August 2011 through November 2011 and from September 2012 through November 2012 were included in this study. We divided the subjects into two groups by blood pressure, hypertension group(81 patients) and non-hypertension group(180 subject). Then we compared electrodermal activity between two groups by using the autonomic bioelectric response device model CP-6000A. The data was analyzed by independent t-test and logistic regression. In this study, there was a significant difference in electrodermal activity(the mean absolute value of positive, negative pulse conductivity) between hypertensive and normotensive group in t-test and electrodermal activity showed the significant influence on the prevalence risk of hypertension with age, body mass index and dyslipidema in binominal logistic regression. In conclusion, hypertensive patients had high level of electrodermal activity compared with normotensive subjects and this finding suggests that electrodermal activity which is explained excess tendency in Korean traditional medicine could be used for diagnosis in hypertension patients at Korean traditional medical clinic.

Nursing Approach of an Offered Blanket on the Anxiety of Patients Undergoing Brain MRI (담요제공이 Brain MRI 검사를 받는 환자의 불안에 미치는 간호중재적 접근)

  • Park, Jin-Yeong;Kim, Kye-Ha
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.623-632
    • /
    • 2016
  • The purpose of the present study was to evaluate the effect of an offered blanket on the anxiety of patients undergoing brain MRI. The participants were 52 patients who underwent brain MRI in C university hospital of G city. Blanket was applied to the experimental group (n=26) before MRI. Data were collected from May to December 2015, and analysed using the chi-squared test, the independent t-test, and repeated measures ANOVA. The results showed that there was no significant difference in the anxiety measured by STAI of the two groups. But, the level of anxiety measured by the visual analog scales was reduced in the experimental group (t=-2.75, p=0.008). There were no difference in the blood pressure and pulse rate in the experimental and control groups. Therefore, further study is needed to decrease the level of anxiety of patients undergoing brain MRI.

Inhibitory Modulation of 5-Hydroxytryptamine on Corticostriatal Synaptic Transmission in Rat Brain Slice

  • Choi, Se-Joon;Chung, Won-Soon;Kim, Ki-Jung;Sung, Ki-Wug
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.6
    • /
    • pp.295-301
    • /
    • 2003
  • Striatum plays a crucial role in the movement control and habitual learning. It receives an information from wide area of cerebral cortex as well as an extensive serotonergic (5-hydroxytryptamine, 5-HT) input from raphe nuclei. In the present study, the effects of 5-HT to modulate synaptic transmission were studied in the rat corticostriatal brain slice using in vitro extracellular recording technique. Synaptic responses were evoked by stimulation of cortical glutamatergic inputs on the corpus callosum and recorded in the dorsal striatum. 5-HT reversibly inhibited coticostriatal glutamatergic synaptic transmission in a dose-dependent fashion (5, 10, 50, and $10{\mu}M$), maximally reducing in the corticostriatal population spike (PS) amplitude to $40.1{\pm}5.0$% at a concentration of $50{\mu}M$ 5-HT. PSs mediated by non-NMDA glutamate receptors, which were isolated by bath application of the NMDA receptor antagonist, d,l-2-amino-5-phospohonovaleric acid (AP-V), were decreased by application of $50{\mu}M$ 5-HT. However, PSs mediated by NMDA receptors, that were activated by application of zero $Mg^{2+}$ aCSF, were not significantly affected by $50{\mu}M$ 5-HT. To test whether the corticostriatal synaptic inhibitions by 5-HT might involve a change in the probability of neurotransmitter release from presynaptic nerve terminals, we measured the paired-pulse ratio (PPR) evoked by 2 identical pulses (50 ms interpulse interval), and found that PPR was increased ($33.4{\pm}5.2$%) by 5-HT, reflecting decreased neurotransmitter releasing probability. These results suggest that 5-HT may decrease neurotransmitter release probability of glutamatergic corticostriatal synapse and may be able to selectively decrease non-NMDA glutamate receptor-mediated synaptic transmission.

Ultra-Low Powered CNT Synaptic Transistor Utilizing Double PI:PCBM Dielectric Layers (더블 PI:PCBM 유전체 층 기반의 초 저전력 CNT 시냅틱 트랜지스터)

  • Kim, Yonghun;Cho, Byungjin
    • Korean Journal of Materials Research
    • /
    • v.27 no.11
    • /
    • pp.590-596
    • /
    • 2017
  • We demonstrated a CNT synaptic transistor by integrating 6,6-phenyl-C61 butyric acid methyl ester(PCBM) molecules as charge storage molecules in a polyimide(PI) dielectric layer with carbon nanotubes(CNTs) for the transistor channel. Specifically, we fabricated and compared three different kinds of CNT-based synaptic transistors: a control device with $Al_2O_3/PI$, a single PCBM device with $Al_2O_3/PI:PCBM$(0.1 wt%), and a double PCBM device with $Al_2O_3/PI:PCBM$(0.1 wt%)/PI:PCBM(0.05 wt%). Statistically, essential device parameters such as Off and On currents, On/Off ratio, device yield, and long-term retention stability for the three kinds of transistor devices were extracted and compared. Notably, the double PCBM device exhibited the most excellent memory transistor behavior. Pulse response properties with postsynaptic dynamic current were also evaluated. Among all of the testing devices, double PCBM device consumed such low power for stand-by and its peak current ratio was so large that the postsynaptic current was also reliably and repeatedly generated. Postsynaptic hole currents through the CNT channel can be generated by electrons trapped in the PCBM molecules and last for a relatively short time(~ hundreds of msec). Under one certain testing configuration, the electrons trapped in the PCBM can also be preserved in a nonvolatile manner for a long-term period. Its integrated platform with extremely low stand-by power should pave a promising road toward next-generation neuromorphic systems, which would emulate the brain power of 20 W.

Validation of sequence test method of Pb-free solder joint for automotive electronics (자동차 전장품용 무연솔더 접합부의 시리즈 시험 유효성)

  • Kim, A Young;Oh, Chul Min;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.25-31
    • /
    • 2015
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from electronic devices and system. Specifically, reliability issue of lead-free solder joint have an increasing demand for the car electronics caused by ELV banning. The authors prepared engine control unit and cabin electronics soldered with Sn-3.0Ag-0.5Cu (SAC305). To compare with the degradation characteristics of solder joint strength, thermal cycling test (TC), power-thermal cycling test (PTC) and series tests were conducted. Series tests were conducted for TC and PTC combined stress test using the same sample in sequence and continuously. TC test was performed at $-40{\sim}125^{\circ}C$ and soak time 10 min for 1000 cycles. PTC test was applied by pulse power and full function conditions during 100 cycles. Combined stress test was tested in accordance with automotive company standard. Solder joint degradation was observed by optical microscopy and environment scanning electron microscopy (ESEM). In addition, to compare with deterioration of bond strength of quad flat package (QFP) and chip components, we have measured lead pull and shear strength. Based on the series test results, consequently, we have validated of series test method for lifetime and reliability of Pb-free solder joint in automotive electronics.

Effective Control of Stiffness of Tungsten Probe for AFM by Electrochemical Etching (전기화학적 에칭에 의한 AFM용 텅스텐 탐침의 강성 제어)

  • Han, Guebum;Lee, Seungje;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.30 no.4
    • /
    • pp.218-223
    • /
    • 2014
  • This paper presents a method of controlling the stiffness of a tungsten probe for an atomic force microscope (AFM) in order to provide high-quality phase contrast images in accordance with sample characteristics. While inducing sufficient deformation on sample surfaces with commercial Si or $Si_3N_4$ probes is difficult because of their low stiffness, a tungsten probe fabricated by electrochemical etching with appropriately high stiffness can generate relatively large elastic deformation without damaging sample surfaces. The fabrication of the tungsten probe involves two separate procedures. The first procedure involves immersing a tungsten wire with both ends bent parallel to the surface of an electrolyte and controlling the stiffness of the tungsten cantilever by decreasing its diameter using electrochemical etching in the direction of the central axis. The second procedure involves immersing the end of the etched tungsten cantilever in the direction perpendicular to the surface of the electrolyte and fabricating a tungsten tip with a tip radius of 20-50 nm via the necking phenomenon. The latter etching process applies pulse waves every 0.25 seconds to the manufactured tip to improve its yield. Finite element analysis (FEA) of the stiffness of the tungsten probe as a function of its diameter showed that the stiffness of the tungsten probes greatly varies from 56 N/m to 3501 N/m according to the cantilever diameters from $30{\mu}m$ to $100{\mu}m$, respectively. Thus, the proposed etching method is effective for producing a tungsten probe having specific stiffness for optimal use with an AFM and certain samples.

Effects of Banhahubak-tang Extract on Psychological Stress (반하후박탕(半夏厚朴湯) 추출물이 생쥐에 유발된 심리적 스트레스에 미치는 영향)

  • Lim, Se-Hyun;Jeong, Hyun-Yun;Won, Ho-Young;Kim, Hyung-Woo;Choi, Chang-Won;Jeong, Hyang-Sook;Kim, Young-Gyun;Cho, Su-In
    • The Korea Journal of Herbology
    • /
    • v.27 no.4
    • /
    • pp.81-88
    • /
    • 2012
  • Objective : Banhahubak-tang is indicated for globus hystericus, marked by a subjective sensation as if something stuffed in the throat, chest distress, cough or vomiting, greasy whitish, taut and smooth pulse. In this study, the effects of Banhahubak-Tang extract (BHTe) were tested for anti-stress action. Methods : BHTe was extracted by pure water using electronic extractor and then fed to ICR male mice ($20{\pm}2g$) orally with the dose of 100mg/kg/day for five days. Mice were exposed to sociopsychological stress by restraining and seeing foot shock stressed mice for one hour for five days. Results : BHTe administered group showed a tendency of decreasing of serum corticosterone secretion when compared with control group, and BHTe administration also significantly up-regulated noradrenaline secretions in the dorsal cortex of brain. Lipid peroxidation of the brain tissues of mice were tested by measuring malondialdehyde, but BHTe showed no significant change. The elevated plus-maze test was designed to detect the effect of anxiolytic drugs, and BHTe administered group showed a significant increase of latency time. Conclusions : These results suggest that BHTe can effectively rid the psychological stress and it's related diseases.

A Study on 8kbps FBD-MPC Method Considering Low Bit Rate (Low Bit Rate을 고려한 8kbps FBD-MPC 방식에 관한 연구)

  • Lee, See-Woo
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.271-276
    • /
    • 2014
  • In a speech coding system using excitation source of voiced and unvoiced, it would be involved a distortion of speech quality in case coexist with a voiced and unvoiced consonants in a frame. In this paper, I propose a method of 8kbps Multi-Pulse Speech Coding(FBD-MPC: Frequency Band Division MPC) by using TSIUVC(Transition Segment Including Unvoiced Consonant) searching, extraction and approximation-synthesis method in a frequency domain. I evaluate the 8kbps MPC and FBD-MPC. As a result, SNRseg of FBD-MPC was improved 0.5dB for female voice and 0.2dB for male voice respectively. Compared to the MPC, SNRseg of FBD-MPC has been improved that I was able to control the distortion of the speech waveform finally. And so, I expect to be able to this method for cellular phone and smart phone using excitation source of low bit rate.

Self-timed Current-mode Logic Family having Low-leakage Current for Low-power SoCs (저 전력 SoC를 위한 저 누설전류 특성을 갖는 Self-Timed Current-Mode Logic Family)

  • Song, Jin-Seok;Kong, Jeong-Taek;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.8
    • /
    • pp.37-43
    • /
    • 2008
  • This paper introduces a high-speed low-power self-timed current-mode logic (STCML) that reduces both dynamic and leakage power dissipation. STCML significantly reduces the leakage portion of the power consumption using a pulse-mode control for shorting the virtual ground node. The proposed logic style also minimizes the dynamic portion of the power consumption due to short-circuit current by employing an enhanced self-timing buffer. Comparison results using a 80-nm CMOS technology show that STCML achieves 26 times reduction on leakage power consumption and 27% reduction on dynamic power consumption as compared to the conventional current-mode logic. They also indicate that up to 59% reduction on leakage power consumption compared to differential cascode voltage switch logic (DCVS).

Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current (고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화)

  • Kim, Su-Hyon;Choi, Sug-Ju;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl;Kim, Gye-Yeop
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF