• Title/Summary/Keyword: Pulse Analysis

Search Result 2,103, Processing Time 0.026 seconds

A Study on Relationship between Hot Flush and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer in Women Who Complain of Perimenopausal and Postmenopausal Syndrome (갱년기증후군 환자의 안면홍조 증상과 맥 에너지와의 상관성 연구)

  • Bae, Ju-Eun;Lee, Hee-Yoon;Son, Bo-Gil;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.4
    • /
    • pp.1-12
    • /
    • 2016
  • Objectives: The purpose of this study is to analyze the correlation between the pulse energy and hot flush in women who complain of climacteric syndrome. Methods: We analyzed the values of pulse energy on 78 of perimenopausal and postmenopausal women. The symptoms of patients were assessed by Kupperman’s index (KI) and Menopause Rating Scale (MRS). Statistical analysis was performed by Spearman correlation coefficient and student T-test, using SPSS 18.0 for window program. Results: The results were as follows. 1. There were no statistically significant relation between pulse energy of left Cheok subtracted from left Chon and KI, MRS hot flush score. 2. When divided depending on MRS hot flush score, There were no statistically significant differences on pulse energy. Conclusions: The results suggest that there is no correlation between hot flush score and pulse energy.

Time Domain Analysis of Dispersion Characteristics of Pulse for MMIC Design (초고주파 집적회로 설계를 위한 펄스의 시간영역 분산 특성 해석)

  • Kim, Gi-Rae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1755-1760
    • /
    • 2013
  • In this paper, when the pulses propagate on a uniform microstrip line, the distortion of pulse signal caused by dispersion is investigated in time domain. We analyzed dispersion characteristics according to dielectric constant and structure of transmission line, and compared propagating characteristics for square and gaussian pulse according to pulse width, pulse amplitude, and propagation velocity. The results of this paper are compatible to the trade-off determination of relative permittivity, substrate height, strip width and pulse width of signal pulse when a design of MIC and MMIC is necessary.

A Study on Pulse Diagnosis in Women with Polycystic Ovary Syndrome (PCOS) (Polycystic Ovary Syndrome(PCOS) 환자의 맥 분석 연구)

  • Park, Kyung-Dug;Bae, Ju-Eun;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.4
    • /
    • pp.77-88
    • /
    • 2017
  • Objectives: The purpose of this study is to analyze the characteristics of the pulse energy in women with PCOS (Polycystic ovary syndrome) compared with women who have a regular menstrual cycle. Methods: We analyzed the values of pulse energy on 20 patients with PCOS as an experimental group and 40 patients with regular menstrual cycle as a control group. Control group was divided into 20 women with follicular phase and 20 women with luteal phase respectively. Statistical analysis was performed using SPSS/Win 18.0, one way ANOVA and Tukey HSD. Results: The results were as follows. 1. The mean pulse energy of the Right Chon was significantly increased compared with those of the Left Kwan and the Right Kwan among PCOS group. 2. There were no statistically significant pulse energy among control groups. Conclusions: The pulse energy of Lung is bigger than that of Spleen and Liver in PCOS patients compared with women who have a regular menstrual cycle.

A Study on the Recognition of Human Pulse Using Wavelet Transform (웨이브렛 변환을 이용한 맥파의 인식에 관한 연구)

  • 길세기;김낙환;박승환;민홍기;흥승홍
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.269-272
    • /
    • 2000
  • It is need to develop and apply a human pulse diagnosis system providing a quantitative and automatic analysis in the the oriental medicine. In order to analyze quantitatively the characteristic of pulsation, each of points had to be recognized accurately notifying the existence and the position of feature point in the wave form. And getting the period of human pulse. Thus, in this paper, it is proposed the preprocessing method of human pulse and the detection method of period by Wavelet Transformation. The human pulse is seprated from each band through Wavelet Transformation and feature points can be recognized through over the fact, and then the parameter of proposed Mac-Jin parameter is measured. Commonly, Human pulse signal has often various noises which are baseline drift, high frequency noise and so on. So it is significant to remove that noises. Thus, in this paper, the one period of human pulse is deciede and the feature points are detected after doing the preprocessing by wavelet transformation. As a result, it could be confirmed that this method is effective as a real program for the auto-diagnosis of human pulse.

  • PDF

Independent PRF Generation and Control for Frequency Phase Calibration on Mono-pulse Radar at a Remote Location (원격지에서 모노펄스 레이더의 주파수 위상 교정을 위한 독립된 펄스반복주파수 생성 및 제어)

  • Yang, Jaewon;Yoo, Seungoh;Yoon, Jaehyuk;Lee, Dongju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.368-373
    • /
    • 2021
  • This paper presents a method of independent pulse repetition frequency(PRF) generation and control for frequency phase calibration on mono-pulse radar at a remote location. In order to generate an independent PRF signal of 320[Hz], pulse width modulation(PWM) of 16-bit timer/counter was applied. For a precision control of PRF signal, 16-bit timer/counter interrupt was changed for each period. Therefore, average frequency of PRF could be controlled by 0.0001[Hz]. To calibrate a frequency phase of mono-pulse radar at a remote location, the proposed PRF generator with a precision control of frequency was used regardless of receiving PRF signal from a radar. For the verification of the proposed PRF generator, theoretical analysis and experimental results are included.

Non-iterative pulse tail extrapolation algorithms for correcting nuclear pulse pile-up

  • Mohammad-Reza Mohammadian-Behbahani
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4350-4356
    • /
    • 2023
  • Radiation detection systems working at high count rates suffer from the overlapping of their output electric pulses, known as pulse pile-up phenomenon, resulting in spectrum distortion and degradation of the energy resolution. Pulse tail extrapolation is a pile-up correction method which tries to restore the shifted baseline of a piled-up pulse by extrapolating the overlapped part of its preceding pulse. This needs a mathematical model which is almost always nonlinear, fitted usually by a nonlinear least squares (NLS) technique. NLS is an iterative, potentially time-consuming method. The main idea of the present study is to replace the NLS technique by an integration-based non-iterative method (NIM) for pulse tail extrapolation by an exponential model. The idea of linear extrapolation, as another non-iterative method, is also investigated. Analysis of experimental data of a NaI(Tl) radiation detector shows that the proposed non-iterative method is able to provide a corrected spectrum quite similar with the NLS method, with a dramatically reduced computation time and complexity of the algorithm. The linear extrapolation approach suffers from a poor energy resolution and throughput rate in comparison with NIM and NLS techniques, but provides the shortest computation time.

A Study on Analysis of the Hydrogen-Oxygen Gas Generator Using Pulse Power Supply (펄스전원에 의한 수산화가스 발생기에 관한 연구)

  • 이정민;강병희;목형수;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.377-385
    • /
    • 2001
  • The mixed gas of Hydrogen and Oxygen is gained from water electrolysis reaction. It has constant volume ratio 2 : 1 Hydrogen and Oxygen, and it is used as a source of thermal energy by combustion reaction. This gas has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG used for gas welding machine. So several studies of this gas are actively in progress nowadays. The object of this study is the optimization of power condition in the side of electricity for the Hydrogen-Oxygen gas generator, Firstly chemical analysis of electrolysis is conducted, and the relation of electrical energy and chemical energy is quantitatively investigated through Faraday's laws of electrolysis. After that, pulse power supply is designed for basic experiment which could be applied to the analysis of Hydrogen-Oxygen gas generator. In the basis of above steps, comparison and analysis of Hydrogen-Oxygen gas generator was conducted as variable frequency using pulse Power supply.

  • PDF

Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device (자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색)

  • Yu, Jun-Sang;Chang, Sei-Jin;Sun, Seung-Ho;Hong, Yu-Sik;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.1
    • /
    • pp.63-76
    • /
    • 2013
  • The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.

A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer (3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구)

  • Kang, Hee-Jung;Kwon, Young-Sang;Kim, Dal-Lae;Kim, Kyung-Cheol;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.