• 제목/요약/키워드: Pulsating components

검색결과 25건 처리시간 0.027초

40 Gbps All-Optical 3R Regeneration and Format Conversion with Related InP-Based Semiconductor Devices

  • Jeon, Min-Yong;Leem, Young-Ahn;Kim, Dong-Churl;Sim, Eun-Deok;Kim, Sung-Bock;Ko, Hyun-Sung;Yee, Dae-Su;Park, Kyung-Hyun
    • ETRI Journal
    • /
    • 제29권5호
    • /
    • pp.633-640
    • /
    • 2007
  • We report an experimental demonstration of 40 Gbps all-optical 3R regeneration with all-optical clock recovery based on InP semiconductor devices. We also obtain alloptical non-return-to-zero to return-to-zero (NRZ-to-RZ) format conversion using the recovered clock signal at 10 Gbps and 40 Gbps. It leads to a good performance using a Mach-Zehnder interferometric wavelength converter and a self-pulsating laser diode (LD). The self-pulsating LD serves a recovered clock, which has an rms timing jitter as low as sub-picosecond. In the case of 3R regeneration of RZ data, we achieve a 1.0 dB power penalty at $10^{-9}$ BER after demultiplexing 40 Gbps to 10 Gbps with an eletroabsorption modulator. The regenerated 3R data shows stable error-free operation with no BER floor for all channels. The combination of these functional devices provides all-optical 3R regeneration with NRZ-to-RZ conversion.

  • PDF

펄스 옥시메터의 산소포화도 추출 알고리즘을 위한 계산모델 설계에 관한 연구 (Study on the Design Computing Model for SpO Extraction Algorithm on Pulse Oximetry)

  • 김윤영;김도철;이윤선
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권1호
    • /
    • pp.25-32
    • /
    • 1998
  • 본 논문은 맥동 성분의 적분비를 이용한 펄스 옥시메터의 산소포화도 계산 모델의 설계 및 분석에 관한 것이다. 제안된 알고리즘은 손가락이나 귀볼에서 투과된 광신호를 직류성분 A 와 맥동성분 A , Sinwt 잡음성분 A 등으로 모델링하였다. 또한 맥동성분과 직류성분의 효율적인 분리를 위해 맥동성분에 대한 평균치 A 를 직류성분으로 규정하였고, 적분비를 이용하여 잡음성분을 어떻게 제거 하는지에 관하여도 기술하였다. 본 알고리즘은 신호의 맥동성분을 단순 가산에 의한 적분 알고리즘을 구성할 수 있기 때문에 산소농도 추출을 간략하게 수행할 수 있는 장점을 가지고 있다. 알고리즘 성능평가는 펄스 옥시메터에서 많이 사용하고 있는 맥동성분의 진폭비를 이용한 방법과 비교하였다. 비교결과는 본 알고리즘에서 샘플링 시간을 고려한 최적의 조건인 4주기의 면적계산 주기를 가졌을 때 기존의 방식보다 평균오차가 1%정도 향상되었으며, 회귀직선의 신뢰도를 보여주는 결정계수 r 도 0.985로 0.970보다 더 좋은 결과를 얻을 수 있었다.

  • PDF

An Experimental Study on Velocity Profiles and Turbulence Intensity of Developing Turbulent Pulsating Flows in the Entrance Region of a Square Duct

  • Park, G.M.;Koh, Y.H.
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.235-242
    • /
    • 1993
  • The flow characteristics of developing turbulent pulsating flows are investigated experimentally in the entrance region of a square duct ($40mm{\times}40mm$ and 4,000mm). Mean velocity profiles, turbulence intensity and entrance length are measured by using a hot-wire anemometer system together with data acquisition and processing systems. It is found that the velocity waveforms are not changed in the fully developed flow region where that $x/Dh{\geq}40$. For turbulent pulsating flow, the turbulent components in the velocity waveforms increase as the dimensionless transverse position approaches the wall. Mean velocity profiles of the turbulent steady flows follow the one-seventh power law profile in the fully developed flow region. Turbulence intensity increases as the dimensionless transverse position increases from the center to the wall of the duct, and is slightly smaller in the accelerating phase than in the decelerating phase for the turbulent pulsating flows. The entrance length of the turbulent pulsating flow is about 40 times as large as the hydraulic diameter under the present experimental conditions.

  • PDF

맥동주파수의 변화에 따른 충돌제트의 열전달 특성 (Heat Transfer Characteristics Of Impinging jet with Pulsating Frequency)

  • 김용일;박복춘;백병준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.278-284
    • /
    • 2000
  • The method of Impinging jet was applied lots of part in industrial field as a cooling of as gas turbine blade, a annealing of metal and plastic sheets, drying of textile, veneer paper, X-ray medical devices, laser weapons and electronic components. This study's main factor is reciprocating Jet impingement perpendicular to the heated Surface. We researched the effect of heat transfer and enhancement with pulsating air jet. The pulsating air jet has an improvement in pulsating Frequencies((f= 0.5, 1, 1.5, 3Hz) and nozzle-to-plate distances($l/d=\;2{\sim}4,\;6{\sim}8,\;4{\sim}6,\;8{\sim}10$).

  • PDF

가변속 3상 유도 전동기의 토오크 변동 최소화를 위한 OPtimal PWM 방식 (Optimal PWM Strategy for Minimization of Torque Ripplis of a Variable Speed 3phase Induction Motor)

  • 이윤종;정동화
    • 대한전기학회논문지
    • /
    • 제35권6호
    • /
    • pp.217-225
    • /
    • 1986
  • This paper describes the Optimal PWM strategy to reduce a pulsating harmonic torque for a variable-speed drive of 3 phase induction motor. This paper suggests the new Optimal control theory which consists of 1) defining a performance index related to the unwanted effects of the voltage harmonics, (i.e., the components of pulsating harmonic torques) 2) achieving its minimization by a suitable choice of the switching patterns. (i.e., of the commutation angles) This PWM strategy is compared with the conventional SPWM strategy by numerical method. It is believed that this proposed strategy can reduce more harmonic components and pulsating harmonic torques than SPWM strategy. Also, We could verify the validety of the numerical method by a result of simulation analysis of a variable speed 3phase induction motor.

  • PDF

맥동성분의 적분비를 이용한 펄스 옥시메터의 산소포화도 계산모델 설계 및 분석 (Architecture & Analysis of $SpO_2$ Computing Model Using Integral Ratio of Pulsating Components)

  • 김윤영;김동철;이윤선
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.267-270
    • /
    • 1997
  • Oxygen saturation is an important parameter in clinical fields; fetal monitoring, apnea, emergency medicine etc. Because of monitoring patients continuously, pulse oximeter that measures oxigen saturation non-invasively is regarded attentively. But, though research about accuracy of signal extraction has been developed, it actually plays a supplementary part in hospital for not trusting the principle of measurement by clinicians. In this paper focusing on these things, first we suggested simple mathematical modelling on separating do components, ac components andnoise components in optical signal transmitted from fingertip or earlobe, and then we considered oxygen saturation computing algorithm using integral ratio of pulsating components. Last, we analyzed its effect by comparing received data.

  • PDF

4각 덕트내에서 난류 맥동유동의 난류특성에 관한 연구 (A Study on Turbulent Characteristics of Turbulent Pulsating Flows in a Square Duct)

  • 박길문;고영하
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.188-198
    • /
    • 1990
  • Turbulent characteristics of turbulent pulsating flows were studied experimentally in a square duct. Velocity waveforms, velocity profiles, and turbulent intensity of turbulent pulsating flow were investigated by using a hot-wire anemometer with data acquisition and a processing system in a square duct with a ratio of 1 ($40mm{\times}40mm$) to 4,000mm long. Turbulent components were shown to be larger in decelerating than in accelerating regions and also larger for a large phase of velocity and U'rms distribution of turbulent flow. The effect of velocity amplitude ratio does not exist for specified time [${\theta}(z^{\prime})$], amplitude ratio (${\mid}U^{\prime}_{rms.os.1}{\mid}/{\mid}U_{m.os.1}{\mid}$), and phase difference (${\Delta}U^{\prime}_{rms.os.1}-{\Delta}U_{m.os.1}$) in either turbulent oscillating or cross-sectional mean velocity components. The effect of dimensionless angular frequency for specified time [${\theta}(z^{\prime})$] can be disregarded because the dimensionless angular frequency does not affect the specified time. The velocity distributions of turbulent pulsating flows for various time-averaged Reynolds numbers are in approximate agreement with the velocity distributions for equivalent Reynolds numbers and 1/7th power law of steady flow.

  • PDF

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

유압관로내 원통형 초크의 분류영역에서 맥동유동의 거동과 유동특성에 관한 연구 (Behavior and flow characteristics of pulsating flow in the jetflow region through cylindrical chokes)

  • 배신철;모양우
    • 대한기계학회논문집
    • /
    • 제19권11호
    • /
    • pp.3041-3053
    • /
    • 1995
  • Cylindrical chokes are used widely as components of hydraulic equipments. The dynamic characteristics between flowrate and pressure drop through the cylindrical chokes were discussed by the frequency characteristics of the chokes. It was assumed no pressure recovery occurred near the downstream of the choke. The pulsating jetflow from the outlet of cylindrical chokes show very complex behaviours which are quite different from the steady jet flow but it's not clarified quantitatively. In order to utilize the chokes as a flowmeter, it is indispensable to discuss the estimation of the dynamics of pressure drop in the downstream jetflow region of cylindrical chokes. In this experimental study, it is clarified that the reattachment length depended on pressure wave is compared with it depended on velocity wave. A pulsating flow is verified by visualization method. In the present study, the flow characteristic variables of laminar pulsating flow are investigated analytically and experimentally in a circular pipe. Characteristic parameters of the ratios of inertia(.PHI.$_{t,1}$) and viscous(.PHI.$_{z,1}$) term to pressure term are introduced to describe the flow pattern of laminar pulsating flow. flow.low.

유체맥동을 고려한 배관계의 진동해석 (Vibration Analysis of Pipes Considering Fluid Pulsation)

  • 서영수;정석현;이성현;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1050-1056
    • /
    • 2006
  • In this paper, a new method for the stability analysis of a pipe conveying fluid which pulsates periodically is presented. The finite element model is formulated liking into consideration of the effects of the fluid pulsating in a pipe. The damping and stiffness matrices in the finite element equation vary with time due to pulsating fluid. Coupled effects of several harmonic components in the velocity of fluid to a pipe is discussed. A new unstable region appears which will not appear in the stability analysis of single pulsating frequency. A method to directly estimate the forced response of pipe is also discussed. The results presented in this paper are verified by the time domain analysis.