• Title/Summary/Keyword: Pulmonary function test (PFT)

Search Result 56, Processing Time 0.028 seconds

A Systematic Review of Home based Pulmonary Rehabilitation in COPD Patients: Randomized Controlled Trials (만성폐쇄성폐질환자의 가정호흡재활 프로그램 효과에 대한 체계적 고찰: 무작위시험설계)

  • Ahn, Min Hee;Choi, Ja Yun;Kim, Yun Hee
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.19 no.2
    • /
    • pp.82-99
    • /
    • 2016
  • Purpose: The purpose of this study was to review systematically the effects of home based pulmonary rehabilitation in chronic obstructive pulmonary disease (COPD) patients using qualitative synthesis. Methods: Studies designed randomized controlled trials were identified to extract data and to assess the quality of studies in 8 domestic and 3 foreign search engines, and hand search reference reviews. Results: A total of 9 studies met the inclusion criteria. Overall, the methodological quality of the studies ranged from average to poor. Home based pulmonary rehabilitation consisted of exercise, education, and psychosocial interventions. Several exercises such as aerobic, strength, respiratory muscle training, and flexibility were used in home based pulmonary rehabilitation for COPD patients. Upper muscle exercise and walking were the most frequently used exercises. The most common topics for education were 'knowledge of the illness' and 'drug management'. Walking distance test (WDT) and quality of life (QoL) were the most frequently measured as the dependent variables to evaluate rehabilitation outcomes, followed by pulmonary function test (PFT) and dyspnea. WDT was the most effective outcome, followed by dyspnea, QoL and PFT. Conclusion: This study informed about the details of scientific and effective home based rehabilitation programs in COPD patients for future researchers and clinicians. These findings can help expand the recognition and accessibility of home based rehabilitation in COPD patients.

Pulmonary Function and Influence Factors among Residents around Gwangyang Steel Mill (광양 제철소 주변지역 거주자들의 폐기능과 영향 요인)

  • Hong, Eun-Ju;Ahn, Gi-Sub;Chung, Eun-Kyung;Choi, Jae-Ho;Guo, Xinbiao;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.182-192
    • /
    • 2011
  • Objectives: This study aims to identify the influential factors on the pulmonary function of targeted general residents in the areas surrounding Gwangyang Steel Mill. Methods: An PFT (Pulmonary Function Test) was conducted from May 2007 to November 2007 on 974 target residents (438 male, 536 female), including an exposed group (674 people) who resided within a radius of 5 km from Gwangyang Steel Mill in Gwangyang-si, Jeollanam-do and a control group (300 people) who resided outside a radius of 15 km. A survey related to personal characteristics, life habits, respiratory diseases and allergic symptoms, medical histories and living environments of the residents was also conducted to identify influential factors on pulmonary function. Results: As %$FEV_1$ and %FVC of the exposed group are 99.17% and 96.98%, respectively, and those of the control group are 105.47% and 101.91%, respectively, with the PFT values of the exposed group being lower than those of the control group (p<0.001), it turns out that the pollution in the industrial complex is likely to trigger a reduction in the pulmonary function of local residents. The odds ratio analysis result for asthma diagnosis history indicates that the odds ratios tend to be higher among surveyed residents who are living near above-average traffic volumes and are using beds, where it is statistically meaningful that especially the odds ratios are higher if the residences are closer to roads (p<0.01, CI=1.12-4.52). The factors that affect the FEV1 are identified as smoking, passive smoking, asthma diagnosis history, nasal congestion symptoms and allergic eye disease ($R^2$=0.154, p<0.001). The factors that affect the FVC are identified as smoking, passive smoking, asthma diagnosis history and allergic coryza ($R^2$=0.158, p<0.001). In addition, the analysis result for the relevance of air pollution levels to pulmonary function ($FEV_1$, FVC) shows that FEV1 and FVC tend to decrease as the concentration of $O_3$ increases. Conclusions: We believe that this study may provide preliminary data for the development of preventive measures for health effects on the residents and environmental health control measures for environmental pollution in the industrial complex area.

A comparative study to evaluate the effect crook sitting position and understanding of test in pulmonary function test on healthy individuals (건강한 성인에서 자세변화와 검사방법의 이해도가 폐기능검사 결과에 미치는 영향)

  • Yon, Jung-Min;Lee, Og-Kyoung
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.263-269
    • /
    • 2017
  • Pulmonary function test (PFT) is a test method to determine respiratory disease. In order to obtain accurate PFT results, it is absolutely necessary to induce the inspector and cooperate with the patient. This study was to observe the importance of understanding and posture of the patient in spirometry. In 2016, 110 healthy experimenter performed spirometry; 1) only heard the explanation, 2) watching video and inspector,s demonstration, 3) twisting legs and bending shoulder. FVC, $FEV_1$, $FEV_1/FVC$, $FEF_{25-75%}$, PEF were measured by spirometry. FVC, $FEV_1$, $FEV_1/FVC$, $FEF_{25-75%}$, PEF were significantly increased before and after the understanding the test method. There was a significant difference in FVC, $FEV_1$, and PEF in the false posture. Reproducibility was significantly different in the experimenter' comprehension and false posture. This study provides accurate understanding of the patient and correct posture should be maintained during the examination to obtain correct and reproducible results of PFT.

The Association between Pulmonary Function Test Result and Combustible Cigarette Smoking or Electrical Cigarette Smoking in Korean Adults : Using the 2014-2019 Korean national health and nutrition examination survey data (한국 성인에서 일반담배 또는 가열 전자담배를 이용한 흡연 형태와 폐 기능 검사 결과와의 관련성: 2014-2019년도 국민건강영양조사 자료를 이용하여)

  • Il-hwan Kim;Il-Hyun Lee;Sae-Ron Shin
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-39
    • /
    • 2024
  • Purpose : Smoking is a major factor in chronic obstructive pulmonary disease (COPD), but the effect of electrical cigarette smoking on COPD development is still uncertain. This study aimed to compare the functions of airways and lungs exposed to combustible cigarettes and electrical cigarettes based on the pulmonary function test (PFT) results from the Korean National Health and Nutrition Examination Survey (NHANES). Methods : This study used data from 8,942 participants with PFT results out of 47,309 total subjects from the 6th to 8th Korean NHANES (2014-2015, 2016-2018, and 2019, respectively). Individuals with diseases such as cancer, ex-smokers, and dual tobacco users were excluded. The PFT results were analyzed according to the COPD diagnostic criteria. After adjusting for confounding variables, a complex sample generalized linear model ANOVA test was performed to investigate the association between PFT results and combustible smoker or electrical cigarette user groups. Results : In an analysis based on the obstructive ventilatory disorders (forced expiratory volume in 1 second[FEV1]/forced vital capacity[FVC]<.7), combustible cigarette smokers showed a 3.46 times higher risk of COPD compared to non-smokers, while electrical cigarette smokers exhibited no significant difference in terms of COPD-related risks compared to non-smokers. FEV1 showed a negative relation with combustible cigarette smokers as reported elsewhere (B=-.07, p<.001). FEV1/FVC was negatively related to both combustible cigarette smokers (B=-.03, p<.001) and electrical cigarette smokers (B=-.02, p<.001). Conclusion : FEV1/FVC decreases were observed in the long-term exposure to both combustible and electrical cigarettes. The lower FEV1 in the combustible cigarette group implies the worsening of the severity of COPD, suggesting more damage to the airways and lungs in the short term. Therefore, the temporary electrical cigarettes use for the transition period in order to smoking cessation potentially aids to reduce the harmful effect of combustible cigarettes in COPD development.

The Clinical report of Asthmatic Patients with CVA by treatment of Homins Placenta Aqua-Acupuncture (뇌졸중을 동반한 천식 환자 자하거 약침 투여 2례)

  • Kim, Sung-Kyun;Han, Jong-Hyun;Shim, Yun-Seub;Lee, Jung-Hee;Kim, Eun-Gon
    • Journal of Pharmacopuncture
    • /
    • v.7 no.3
    • /
    • pp.123-129
    • /
    • 2004
  • Nowadays Asthma is considered to be an inflamatory disease characterized by airway hyperresponsiveness and pulmonary eosinophilia. Hominis Placenta is the dried placenta of a healthy women. It has correspondence to the meridians of lung and kindey. Hominis Placenta acupuncture therapy has effect on invigoration of vital energy nourishing blood and tonifying the essence. It can be applied to the disease as Asthma, pulmonary tuberculosis, chronic hepatitis, liver cirrhosis, degenerative change and cerebrovascular disease. We treated two patients of Asthma with CVA by Homins Placenta Aqua-Acupuncture. The effect of Homins Placenta Aqua-Acupuncture was assessed by analyzing the pulmonary function test(PFT) and Quality of Life Questionnaire for adult Korean Asthmatics(QLQAKA) in patients before and after treatment. Total score was increased. The patients are satisfied our treatment. But further research concerning this is still necessary.

Diesel Exhaust Particle Exposure and its Pulmonary Function Effects (경유차량 배출물질의 노출과 폐기능의 상관성 연구)

  • Lee, Yong-Jin;Kim, Da-Hye;Kim, Soo-Hwan;Kim, Jeong-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.457-468
    • /
    • 2016
  • Traffic-related air pollutants and particulates from diesel exhaust cause for increasing respiratory health problem. Recent epidemiologic studies have reported adverse effects of urban air pollution on various aspects of respiratory health. Bus or truck terminal workers have high probability of exposure to diesel exhaust particle than general office worker. This study was designed to evaluate the relationship between pulmonary function of people who working at the high-density area of diesel vehicles and pulmonary function of people who working at general office in Seoul. So, this study explored the effects on people with exposure to diesel traffic or exposure to diesel traffic, through the pulmonary function test (PFT). There were significant difference in Forced Vital Capacity (FVC) and Forced Expiratory Volume in 1 second ($FEV_1$) between high-exposure group and control. High-exposure to diesel particle were increased risk of reduction in pulmonary function in this study. These results provide the necessity additional research that manage people who working at the high-density area of diesel vehicles.

Comparative Study of Normal Group and Depression Group(pulmonary Function is Below Expected Value) by DSOM (폐기능검사상 기능저하군과 정상군의 한방변증 비교분석)

  • Kim, Jin-Young;Shin, Woo-Jin;Sim, Sung-Heum;Baek, Sang-In;Lee, Byung-Guon;Park, Dong-Il
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.723-733
    • /
    • 2009
  • The purpose of this study is to evaluate the difference about pathogenesis of normal group and depression group(who' pulmonary function is below expected value). Author used DSOM to investigate oriental pathogenesis. Depression group is consisted of people who's FVC%(forced vital capacity)is below 80% or $FEV_1$/FVC%(Forced Expiratory Volume in 1sec/FVC) is below 70%, and they don't have history of lung disease(Athma, tuberculosis, COPD, suchlike). Normal group is consisted of people who's FVC%(Forced Vital Capacity) is in 80-120% and $FEV_1$/FVC%(Forced Expiratory Volume in 1sec/FVC) is above 70%. they also don't have history of lung disease. Author carried out each group's PFT(pulmonary function test) by ATS(American Thoracic Society) method. DSOM was used for oriental pathogenesis investigation of two groups. There was significant difference between normal group and depression group in Kidney(p<0.05). In depression group comparison of sex, there was significant difference between male and female in stagnation of qi, cold, heat, spleen, phlegm(p<0.05). In Normal group there was significant difference between male and female in stagnation of qi, blood stasis, cold, heat, spleen(p<0.05). In depression group comparison of smoke, there was no significant difference between smoker and non-smoker(p<0.05). In Normal group comparison of smoke, there was significant difference between smoker and non-smoker in heat(p<0.05). This result showed difference of the pathogenesis between Depression group and Normal group.

Change of FVC, $FEV_1$ after Discontinuance of Bronchodilator in Coal Workers' Pneumoconiosis Patients (탄광부진폐증 환자에서 기관지확장제 투여 중단 후의 노력성폐활량 및 일초폐활량의 변화)

  • Cheon, Yong-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.245-250
    • /
    • 1988
  • For the evaluation of change of FVC and $FEV_1$ after discontinuance of bronchodilator in the coal workers' pneumoconiosis patients, 17 pairs of patients were selected. They were matched by the age(${\pm}5$ y.o.) and the type of ventilatory impairment. Pulmonary function was measured 2 times bimonthly before and after the drug discontinuance discontinued after measurement of PFT for 2 times. In case group the bronchodilator was discontinued after measurement of PFT for 2 times. In control group there was no interruption of medication. FVC, $FEV_1$ decreased in both group as measurement progress. Simple linear regression coefficients against the month of measurement were calculated in both group and tested for parallelism between two groups. The results of test revealed that both regression coefficients were parallel. So in conclusively, discontinuance of medication of bronchodilator for coal workers pneumoconiosis patients has no effect on the decreasing rate of FVC, $FEV_1$.

  • PDF

Study about the clinical features and Pulmonary function Tst of Endobronchial Tuberculosis (기관지결핵의 임상상 및 폐기능검사에 관한 연구)

  • Chung, Hee-Soon;Lee, Jae-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.147-158
    • /
    • 1996
  • Background : Endobronchial tuberculosis(ET) is known to affect frequently young female and serious complication like bronchial stenosis would occur if early diagnosis and treatment for ET is not performed immediately. But ET shows normal chest roentgenogram in about 10% of patients, and is often confused with bronchial asthma because ET presents clinical features like cough, dyspnea, wheezing in history and physical examination. The pulmonary function test(PFT) feature of ET is not well known, but when we consider the fact that ET is pathophysiologically different from bronchial asthma, if there is any feature of PFT in ET, and we know it, PFT will be very helpful for diagnosis and follow up of ET. Methods : We performed both PFT and bronchoscopy in 68 ET patients who visited Boramae hospital, and were confirmed as ET by bronchoscopic biopsy and were followed prospectively from November 1991 to March 1995. After history taking and physical examination, we performed chest roentgenogram, complete blood count, sputum AFB stain and culture, and also performed PFT before anti-tuberculosis chemotherapy. PFT was classified as restrictive, if only PVC was reduced below 80%, and obstructive, if only FEV1 was reduced below 75%. In the case of both FVC and FEV1 were reduced, PFT was classified as restrictive if FEY1/FVC was greater than 75%, and mixed if FEV1/FVC was reduced below 75%. We repeated the PFT and bronchoscopy for 68 ET patients who were proven by biopsy in the first month and sixth month after starting anti-tuberculosis chemotherapy, and studied the feature and change of PFT of the ET and the relation between PFT and the bronchoscopic finding, and obtained following results. Results: 1) Number of male patients was 12, and that of female patient was 56, and mean age was $35.4{\pm}17yr$.(17-74yr). Clinical symptom was in the order of cough(86.8%), dyspnea(63.2%), fever(17.6%) and hemoptysis (10.3%), and the wheezing and stridor were audible among the 40 patients(58.4%) in the physical examination. 2) Hemoglobin level was below 12g/dl among 25 patients (36.8%), and WBC level was above $10,000/mm^3$ among 9 patients(13.2%) and ESR was above 20 among 46 patients (67.6%) and AFB stain and culture were positive among 50 patients(73.5%). 3) The dominant roentgenographic finding of ET was fibronodular feature in 35 patients(51.5%), pneumonic feature in 14 patients (20.6%), collapse in 11 patients(16.2%), mass-like lesion in 3 patients(4.4%), cavitary lesion in 2 patients(2.9%), and normal in 3 patients(4.4%). 4) PFT feature at the time of diagnosis of ET was normal in 16 patients(23.5%), restrictive pattern in 32 patients (47%), obstructive in 4 patients(5.8%), and mixed in 14 patients(23.5%). So restrictive pattern was the dominate feature of ET. 5) The PFT feature was little correlated with the gross finding of bronchoscopy, but the change of PFT during treatment of ET showed relatively good correlation with the change of bronchoscopic finding. 6) FVC(2.30L vs. 2.61L) and FEV1(1.74L vs. 2.06L) increased significantly (p < 0.01), but FEV1/FVC(82% vs. 83%) and PEF(3.45L/sec vs. 3.95L/sec) did not change significantly after 1 month of treatment (p > 0.01), and there was no significant change among all parameters during first and sixth month of treatment(p > 0.01). Conclusion : PFT may be useful in the diagnosis and treatment follow up of ET but further study would be needed to confirm it.

  • PDF

Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan) (폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교))

  • 이조한
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF