• Title/Summary/Keyword: Pulling Strength

Search Result 55, Processing Time 0.035 seconds

Numerical Analysis on the Flow Field around Tiller Rotor for Soil Improvement in Coastal Fisheries (연안어장의 토질 개선을 위한 경운기 로터 주변의 유동장에 대한 수치해석)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.20-28
    • /
    • 2017
  • The steady-state, incompressible and three-dimensional numerical analysis was performed to investigate the flow fields around the seabed tiller used for soil improvement in coastal fisheries and the pulling force and buoyancy generated by tiller operation. The turbulence model used in this study is a realizable $k-{\varepsilon}$. As a results, at a stationary current or a current speed of 1.2 knots, where rotor rotates in a clockwise direction, a typical vortex pair appears near the tip of the rotor except for the edge, and the strength of the vortex pair increases with the number of revolutions of the rotor. The pulling force of the tiller rotating in the counterclockwise direction increases with the number of revolutions. Also, when the current flows at 1.2 knots and the rotor rotates clockwise, the pulling force of the tiller acts on the upstream side irrespective of the number of rotations of the rotor, so that no force is applied. The buoyancy of the tiller acts on the seawater surface if the flow direction inside the rotor is the same as the direction of rotation of the rotor, regardless of the current velocity, otherwise it acts on the seabed.

Effects of Steel Fiber Reinforcement and the Number of Hooked Bars at R/C Exterior Joints

  • Choi, Ki-Bong
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.181-189
    • /
    • 1999
  • An experimental study was performed on the Pull-out behavior of 90-deg standard hooks from the exterior beam-column connections. the effects of the number of hooked bars and fiber reinforcement of the joint area were investigated with the following conclusions : (1) Under the pull-out action of hooked bars. the damage and cracking of joint area the number of hooks pulling out from a joint increases; (2) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by the pull-out of hooked bars; (3) The pull-out strength and post-peak ductility of hooked bars are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at the exterior joints; and (4) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers . The application of steel fibers to the exterior joints is an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in the beam-column connections.

  • PDF

Growth and characterization of $Al_{2}O_{3}-based\;Y_{3}Al_5O_{12},\;ZrO_{2}$ binary and ternary eutectic fibers

  • Lee, J.H.;Yoshikawa, A.;Kaiden, H.;Fukuda, T.;Yoon, D.H.;Waku, Y.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.4
    • /
    • pp.170-175
    • /
    • 2001
  • It was possible to grow the $Al_{2}O_{3}$ based $Y_{3}A_{5}O_{12}(YAG),ZrO_{2}$ binary and ternary eutectic fibers using micro-pulling down method with a growing rate of 0.1~15 mm/min. While $Al_{2}O_{3}/ZrO_{2}$ showed cellular-lamellar structure, $Al_{2}O_{3}$/YAG and $Al_{2}O_{3}$/YAG/$ZrO_{2}$ternary eutectic fibers showed homogeneous Chinese script lamellar structures. The microstructures of $Al_{2}O_{3}/ZrO_{2}$ binary eutectic fibers changed with solidification rate from lamellar pattern to cellular structure. The interlamellar spacing agreed with the inverse-square-root dependance on pulling rate according to $\lambda$=$kv_p\;{-1/2}$. $Al_{2}O_{3}/ZrO_{2}$ binary eutectic fibers recorded the highest tensile strength of about 1560MPa at room temperature. $Al_2O_3/YAG/ZrO_2$ternary eutectic fiber showed excellent thermal stability to $1200^{\circ}C$ without significant decrease. The maximum strength of ternary eutectic fibers recorded were 1100MPa at $25^{\circ}C$ and 970MPa at $1200^{\circ}C$, respectively.

  • PDF

A clinical report on one case of muscular dystrophy (침치료를 시행한 위증(근이양증(筋異養症)) 환자 치험 1례)

  • Lee, Jang-Won;Kim, Cheol-Han;Hwang, Eui-Hyoung;Kim, Jeong-Yeon
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.6 no.1
    • /
    • pp.177-187
    • /
    • 2005
  • Objective : We want to investigate the patient who has a muscular dystrophy how much muscular strength is improved and general conditions are changed after applying Sa-am acupuncture. Method : The patient who has a muscular dystrophy was evaluated by AchR-ab, VAS, pulling power test after applying Sa-am acupuncture.

  • PDF

Effects of the Number of Hooked Bars on Anchorage Conditions at Exterior Joints (외측 보-기둥 접합부의 정착 상태에 관한 훅크철근의 영향)

  • Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.2
    • /
    • pp.151-156
    • /
    • 1997
  • An experimental study was performed on the pull-out behavior of 90-deg standard hooks from exterior beam-column connections. The effects of the number of hooked bars of joint area were investigated. Under the pull-out action of hooked bars, the damage and cracking of joint area tends to be more extensive as the number of hooks pulling out from a joint increases. The pull-out strength and post-peak ductility of hooked bar are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at exterior joints.

  • PDF

Fundamental Study of Behavior on Steel·Concrete Composite Beam Reinforced Steel Fiber (강섬유를 보강한 강상판 합성보의 거동에 관한 기초적 연구)

  • Seo, Seung-Tag
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.93-98
    • /
    • 2008
  • Steel fibre reinforced concrete (SFRC) were considered a new technology for the construction industry. However today this technology has found wider acceptance among the construction industry. Currently, steel fibres are used in varied segments in many application areas across different segments in the construction industry, especially in tunneling, airports, warehouses, etc. Time and safety are the main factors are among the various advantages which renders steel fibres superior to the competing product. For fibers reinforcing, The maximum load carrying capacity is controlled by fibers pulling out of the composite because fiber reinforcing does not have a deformed surface like larger steel reinforcing bars. The study demonstrated that above concept is applicable and effective in concrete structure by analytical study. The analytical result appears that SFRP have the potential to significantly increase the strength of existing concrete structures, while at the same time dramatically improving their fracture energy characteristics.

  • PDF

Manufacture of Continuous Glass Fiber Reinforced Polylactic Acid (PLA) Composite and Its Properties (연속 유리섬유 강화 폴리유산 복합재료의 제조 및 물성)

  • Roh, Jeong U;Lee, Woo Il
    • Composites Research
    • /
    • v.26 no.4
    • /
    • pp.230-234
    • /
    • 2013
  • The continuous glass fiber reinforced poly-lactic acid (PLA) composite was manufactured by direct melt impregnation. The mechanical and thermal properties of continuous glass fiber reinforced PLA composite were observed. Measured properties were compared with the reference values of neat PLA and the injection molded glass fiber/ PLA composite. The continuous glass fiber reinforced PLA composite having a fiber volume fraction of 27.7% shows enhanced tensile strength of 331.1 MPa, flexural strength of 528.6 MPa, and flexural modulus of 24.0 GPa. The enhanced heat deflection temperature (HDT) and the increased cystallinity were also observed. The degree of impregnation as a function of pulling speed was also assessed. The degree of impregnation at the pulling speed of 5 m/min was over 90% in this research.

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.

Study on the Friction Characteristics of Advanced High Strength Steel Sheet (초고강도강판의 마찰특성에 관한 연구)

  • Kim, N.J.;Kim, S.H.;Jung, K.R.;Park, S.B.;Keum, Y.T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.250-253
    • /
    • 2009
  • In this study, the friction test was performed to find friction characteristics of advanced high strength steel (AHSS) sheets and the multiple regression method was employed to obtain friction models. The friction coefficients associated with the lubricant viscosity, drawing speed, and blank holding pressure are measured. Differently from GA steel sheets, the effects of the lubricant viscosity and pulling speed are a little, which are explained by a theory of adhesion and wear as well as a deformation of friction surface. In addition, the effects of friction parameters are numerically represented by friction regression models.

  • PDF

Characteristics of Pultruded GFRP and Buckling Behavior of Angle and Tubular Member (인발성형 GFRP 부재의 특성 변화와 앵글 및 튜브 부재의 좌굴 거동 분석)

  • 이성우;신경재;김현정
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.15-19
    • /
    • 2000
  • Recently Western countries are now beginning to use ACM (Advanced Composites Material), in the construction industry Compared with existing construction materials, ACM possesses many advantages such as light-weight, high-strength, corrosion resistant property. Among other fabrication process of ACM, pultrusion is one of the promising one for civil infrastructure application. In this paper, the structural characteristics of pultruded GFRP strip and structural members of angle and tube type were studied. For the strip, parametric studies of pultrusion process has been carried out. Considered parameters were volume fraction, temperature, pulling speed and fiber orientations. For the pultruded angle and tube, compression test and buckling analysis has been carried out. The results were compared with calculated values using coded formulae

  • PDF