• Title/Summary/Keyword: Pull-out resistance

Search Result 126, Processing Time 0.023 seconds

Pull-Out Properties of Steel Strip Reinforcement with Transverse Steel Bar (지지부재를 설치한 띠형 강판보강재의 인발마찰 특성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Ju, Jae-Woo;Park, Jong-Beom
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.31-37
    • /
    • 2007
  • A steel strip reinforcement for the reinforced earth structures was recently developed to substitute the existing ribbed steel strip reinforcement. The developed reinforcement consists of the punched steel strip having dimension of 65mm width and 4.5mm thickness and the transverse steel bar for increasing bearing resistance. The punched steel strip has holes of 11mm diameter in every 50cm spacing with 2mm rising around perimeter of the holes. A series of shear friction tests and pull-out tests were carried out to evaluate the friction properties of the developed reinforcement. The results of these tests show that pull-out resistance of the developed reinforcement was significantly increased when the transverse steel bars are installed in the punched steel strip.

  • PDF

Torsional Micromechanical Switching Element Including Bumps for Reducing the Voltage Difference Between Pull-in and Release (Pull-in과 release 전압차 감소용 돌기구조를 갖는 비틀림형 초소형 기계적 스위칭 소자)

  • Ha, Jong-Min;Han, Seung-O;Park, Jeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.471-475
    • /
    • 2001
  • ln this paper, a micromachined micromechanical switch is presented. The presented switch is operated in the vertical direction to the substrate by an electrostatic force between two parallel plates. The moving plate is pulled down to connect the bumps of the bias node$(V_{DD}/ or GND)$ to the bumps of the output node when a oltage difference exists between the moving plate and the input plate. The switch was designed to operate at a low switching voltage$(\risingdotseq5V)$ by including a large-area, narrow-gap, parallel plate capacitor A theoretical analysis of the designed switch was performed in order to determine its geometry fitting the desired pull-in voltage and release voltage. The designed switch was fabricated by surface micromachining combined with Ni electroplating. From the experimental results of the fabricated switch, its pull-in voltage came Out to be less than 5V and the measured maximum allowable current was 150mA. The measured average ON-state resistance was about 8$\Omega$, and the OFF-state resistance was too high to be measured with digital multimeter.

  • PDF

Performance test of Chemical Anchor Bolts for Concrete Repair (콘크리트보수용 접착제를 이용한 Anchor Bolt의 인발지지력 산정에 관한 실험적 연구)

  • Kim, Yon-Gon
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.85-91
    • /
    • 2002
  • A research on the performance of retrofit anchors was conducted using adhesives for rehabilitation. From the pull-out tests of the chemical anchors, the effect of the hole diameter, spacer, temperature, moisture, embedment depth, and aging time were investigated. The spacer did not directly increased the pull-out load hilt increased post-yielding resistance therefore the ductility of the retrofit anchors. When the hole was cleaned and dried after the immersion, the pull-out load was greatly increased compared to the wet hole. A design equation was unposed depending on the embedment depth of the anchor bolt.

A Study on the Behavior of Non-Metallic Anchoring System for FRP Tendons (고성능 팽창재를 이용한 FRP 긴장재의 정착에 관한 연구)

  • 김덕현;조병완;이계삼;김영진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.23-28
    • /
    • 2001
  • Since non-corrosive Fiber Reinforced Polymer(FRP) tendons have been in increasing use for underground and coastal structures constantly contacted with fresh water or sea water because of their superiority to metallic ones in corrosion-resistance, new non-metallic anchoring system for FRP tendons has been developed and investigated to verify the effectiveness of tendon force, which consist of mainly FRP pipes and Highly Expansive Mortar(HEM). The major factors considered in this experiment were expansive pressures of HEM during its hydration, sleeve lengths and types, and anchoring methods of tendon. New anchoring system were investigated from the pull-out tests. The pull-out procedures of the FRP tendons in the various pipe filled with HEM were analyzed and improved ideas were suggested to develop novel non-metallic anchoring system for FRP tendons The pull-out tests for the FRP tendon and new non-metallic anchoring system were conducted. The results show that non-metallic anchoring system for the FRP tendon has been more stablized due to the gradual expansive pressrure of HEM, as tims goes. Since tile lower stiffness of FRP pipes causes the weakness of anchoring force, it requires the increase of stiffness using a carbon fiber or an increased section area.

  • PDF

Experimental bond behavior of hybrid rods for concrete reinforcement

  • Nanni, Antonio;Nenninger, Jeremy S.;Ash, Kenneth D.;Liu, Judy
    • Structural Engineering and Mechanics
    • /
    • v.5 no.4
    • /
    • pp.339-353
    • /
    • 1997
  • Fiber reinforced plastic (FRP) rods provide certain benefits over steel as concrete reinforcement, such as corrosion resistance, magnetic and electrical insulation, light weight, and high strength. FRP composites can be combined with a steel core to form hybrid reinforcing rods that take advantage of properties of both materials. The objective of this study was to characterize the bond behavior of hybrid FRP rods made with braided epoxy-impregnated aramid or poly-vinyl alcohol FRP skins. Eleven rod types were tested using two concrete strengths. Specific topics examined were bond strength, slip, and type of failure in concentric pull-out tests from concrete cubes. From analysis of identical pull-out tests on both hybrid and steel rods, information on relative bond strength and behavior were obtained. It is concluded that strength is similar but slip in hybrid rods is much higher. Hybrid rods failed either by pull-out or splitting the concrete block (with or without yielding of the steel core). Experimental data showed consistency with similar test results presented in the literature.

A Study on the Behavioral Characteristics of a Circular Foundation Dominated by Pull-Out Load through Field Test (현장시험을 통한 인발하중이 지배적인 원형기초의 거동 특성 연구)

  • Shin, Kyung-Ha;Lee, Seung-Ho;Lee, Dong-hyuk;Park, Du-hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.53-62
    • /
    • 2021
  • For the rational application of LRFD, which is actively applied in Korea, for the study of the pull-out load and the horizontal load, which are insufficient examples, a circular foundation based on the transmission tower foundation, which is a socially important structure, through field tests in single and mixed layer. Factors that can affect the design were studied by analyzing the resistance of each stratum to pull-out and horizontal loads.

Setting up Relationship between Pull-out Resistance of Helical Anchor and Rotational Penetration Torque for Methodology Development (헬리컬 앵커개발 및 적용을 위한 앵커의 회전 관입 토크와 인발저항력과의 상관관계 정립)

  • Kim, Nak-Kyeong;Kim, Young-Uk;Moon, Jun-Ho;Xin, Zhen-Hua;Gu, Kyo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.661-667
    • /
    • 2016
  • This study evaluated the potential of methodology development of the helical type anchor for soft ground applications. The rotational penetration of the helix structure might make construction-steps easy without the soil spitting and reusable rods could reduce the material cost. Removal of the anchors would be simple as a construction, which can be named the removal anchor. The anchoring resistance after construction is strongly related to the number of helixes resulting in a concise design process. The investigation involved a chamber test with soft soils. In the test, a specially designed and fabricated helical anchor and torque-driver were used to obtain the maximum pull-out resistance of the anchor after rotational penetration. As a result of the tests, The rotational torque and pull-out resistance have a proportional relationship with the strength of the prepared soils. Within the range of the study, the torque of the anchor penetrating increased with increasing pull-out resistance.

Analysis on the Tensile Fracture Behavior of SFRC (SFRC의 인장 파괴거동에 대한 해석)

  • 김규선;이차돈;심종성;최기봉;박제선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.65-72
    • /
    • 1993
  • Steel fiber reinforced concrete(SFRC) which is made by short, randomly distributed steel fibers in concrete is superior in its tensile mechanical properties to plain concrete in enhancement of tensile strength and tensile ductility. These improvements are attributed to crack arresting mechanism and formation of longer crack paths due to fibers , which as a consequence lead to increase in energy absorption capacity of SFRC. In the post-peak region under tensile stresses, major macrocrack forms at critical section. The opening of this macrocrack is mainly resisted by both of the fiber pull-out bridging the cracked surfaces and the resistance by matrix softening. In this study, micromechaincal approach has been made in order to simulate tensile behavior of SFRC and based on which the theoretical model is presented. This model reflects the features of both the composite material concept and the spacing concept in predicting tensile strength of SFRC. The model also takes into account for the effects of matrix tensile softening and fiber bridging by pull-out on the resistance for the post-peak behavior of SFRC. It has been shown that the developed model satisfactory predicts the experimental results.

  • PDF

Moment Resistance Performance Evaluation of Larch Glulam Joint Bonded in Glass Fiber Reinforced Plastic Rods (봉형 GFRP를 삽입접착한 낙엽송 집성재 접합부의 모멘트저항 성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Jung, Hong-Ju;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.60-67
    • /
    • 2015
  • In order to evaluate the bond performance of domestic larch glulam and the glass fiber reinforced plastic (GFRP) rod, the specimen with the GFRP rod bonded-in domestic larch glulam for pull-out test was produced. The test was carried out using various specimens with different gluing depth, width of glue-line and type of adhesive. The cantilever type rahmen structure specimen with bonded-in GFRP rods was produced based on the result of pull-out test, and its moment resistance performance was compared and examined with the moment resistance performance of slotted-in steel plate specimen. As a result of the pull-out test, the most excellent bond performance was found when the insertion depth of GFRP rods was 5 times larger than the diameter of GFRP rods. When the glue-line thickness was 1 mm, the bond performance improved by 17%~29% in comparison to the bond performance in the case of the glue-line thickness of 2 mm. Also, the bonded strength of the specimen used with poly-urethane adhesive was 2.9~4.0 times greater than the bonded strength of specimen used with resorcinol adhesive. The cantilever type rahmen structure specimen with bonded-in GFRP rods showed the moment resistance performance 0.82 times lower in comparison to the slotted-in steel plate specimen used with the drift pin, but the initial stiffness was similar as 0.93 times.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.