• 제목/요약/키워드: Pull-out Tests

검색결과 225건 처리시간 0.023초

고성능 팽창재를 이용한 FRP 긴장재의 정착에 관한 연구 (A Study on the Behavior of Non-Metallic Anchoring System for FRP Tendons)

  • 김덕현;조병완;이계삼;김영진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.23-28
    • /
    • 2001
  • Since non-corrosive Fiber Reinforced Polymer(FRP) tendons have been in increasing use for underground and coastal structures constantly contacted with fresh water or sea water because of their superiority to metallic ones in corrosion-resistance, new non-metallic anchoring system for FRP tendons has been developed and investigated to verify the effectiveness of tendon force, which consist of mainly FRP pipes and Highly Expansive Mortar(HEM). The major factors considered in this experiment were expansive pressures of HEM during its hydration, sleeve lengths and types, and anchoring methods of tendon. New anchoring system were investigated from the pull-out tests. The pull-out procedures of the FRP tendons in the various pipe filled with HEM were analyzed and improved ideas were suggested to develop novel non-metallic anchoring system for FRP tendons The pull-out tests for the FRP tendon and new non-metallic anchoring system were conducted. The results show that non-metallic anchoring system for the FRP tendon has been more stablized due to the gradual expansive pressrure of HEM, as tims goes. Since tile lower stiffness of FRP pipes causes the weakness of anchoring force, it requires the increase of stiffness using a carbon fiber or an increased section area.

  • PDF

Experimental bond behavior of hybrid rods for concrete reinforcement

  • Nanni, Antonio;Nenninger, Jeremy S.;Ash, Kenneth D.;Liu, Judy
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.339-353
    • /
    • 1997
  • Fiber reinforced plastic (FRP) rods provide certain benefits over steel as concrete reinforcement, such as corrosion resistance, magnetic and electrical insulation, light weight, and high strength. FRP composites can be combined with a steel core to form hybrid reinforcing rods that take advantage of properties of both materials. The objective of this study was to characterize the bond behavior of hybrid FRP rods made with braided epoxy-impregnated aramid or poly-vinyl alcohol FRP skins. Eleven rod types were tested using two concrete strengths. Specific topics examined were bond strength, slip, and type of failure in concentric pull-out tests from concrete cubes. From analysis of identical pull-out tests on both hybrid and steel rods, information on relative bond strength and behavior were obtained. It is concluded that strength is similar but slip in hybrid rods is much higher. Hybrid rods failed either by pull-out or splitting the concrete block (with or without yielding of the steel core). Experimental data showed consistency with similar test results presented in the literature.

균열점토의 균열진행에 대한 강섬유의 보강효과 (Effects of Reinforcement of Steel Fibers on the Crack Propagation of Fissured Clays)

  • 유한규
    • 한국지반공학회지:지반
    • /
    • 제10권3호
    • /
    • pp.119-134
    • /
    • 1994
  • 균열점토에 대한 강섬유 사용 가능성을 평가하기 위하여 균열이 있는 보강점토와 비보강점토 시료에 대한 일축압축실험을 실시하였다. 실험결과 강섬유 보강으로 인하여 균열의 시작과 진행에 대한 저항력에 증가하므로써 균열 시작시 응력과 파괴시 극한응력이 증가되었다. 균열의 시작과 진행에 대한 저항력의 증가는 점토시료에서 강섬유에 의한 균열진행의 억제 또는 진행방향의 변경과 관련되어 있음을 알 수 있었다. 파괴역학 이론과 섬유로 보강된 물질에서의 일반미케니즘을 적용하여 실험결과에 대한 이론적인 해석이 이루어졌다. 해석결과 강섬유의 인발작용을 통한 연결효과로 인하여 시료에서 균열의 진행에 대한 저항력이 증가됨을 알 수 있었다. 이론적인 분석에 의하여 예측된 인발력은 인발실험으로 부터 산정된 값과 비교적 잘 일치되었다.

  • PDF

NDB 쏘일네일링 시스템의 거동특성 평가에 관한 실험적 고찰 (An Experimental Study on the Analysis of Behavior Characteristics of the NDB Soil Nailing System)

  • 김홍택;정성필;박시삼;전경식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.521-528
    • /
    • 2003
  • In this study, a newly modified soil nailing technology called as the NDB(New Down and Board) soil nailing system is introduced. To improve the trafficability, workability, and economical efficiency, SMC(Sheet Molding Compound) board is adopted instead of using the concrete block facing. The SMC board has a distinct advantage of showing a fine view by directly coating with any kind of environmental photos. Composite material properties of the SMC board and cement grout are distinguished features of the NDB soil nailing system. In the present study, both laboratory tests(bending and punching failure tests) and field pull-out tests are carried out to analyze the behavior characteristics of the NDB soil nailing system, including the stress and strain distribution.

  • PDF

제거식 쏘일네일 벽체의 적용성에 관한 연구 (A Study on Application of Removable Soil Nail Walls)

  • 김홍택;강인규;정성필;박사원;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.481-488
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study controlled displacement and controlled force field pull-out tests are carried out 7 times in order to evaluate short-term and long-term pull-out characteristics of the removable soil nail. For evaluating application of removable soil nailing system, bending tests of removable soil nails and tensile tests of fixed sockets are carried out. In the removable soil nailing system, the predicted horizontal displacements from FLAC-2D are also compared with the field measurements occurred in stepwise excavation. And approach for the stability analysis of removable soil nailing system after removed is proposed.

  • PDF

Experimental and analytical behaviour of composite slabs

  • Lopes, Emanuel;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제8권5호
    • /
    • pp.361-388
    • /
    • 2008
  • The Eurocode 4 presents some negative aspects in the design of composite slabs by the m-k Method or the Partial Connection Method. On one hand, the component chemical adherence is not accounted for in the connection between the profiled steel sheet and the concrete. On the other hand, the application of these methods requires some fitting parameters that must be determined by full scale tests. In this paper, the Eurocode 4 methods are compared with a method developed at the Federal Polytechnic School of Lausanne, based on pullout tests, which can be a valid alternative. Hence, in order to calculate the necessary parameters for the three methods, several tests have been performed such as the full scale test described in Eurocode 4 and pull-out tests. This last type of tests is of small dimensions and implicates lower costs. Finally, a full-scale test of a steel-concrete composite slab with a generic loading is presented, with the goal of verifying the analytical formulation.

현장인발시험을 통한 섬유형 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Geosynthetic Fiber Nail System from the Field Pull-Out Tests)

  • 김홍택;박시삼;조병국;정성필
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.342-347
    • /
    • 2004
  • Excavation nearby the existing structures is being performed vigorously to get the greatest use of land along with fast economic growth in the downtown area. The application of soil nailing system gradually increases because of an advantage of soil nailing system adjacently constructed in the existing structures. In this study, friction resistance by pull-out is considered as main resistance except resistance formed by flexural rigidity of nail observing that resistance of flexural rigidity is about $0{\sim}15\;%$ of whole safety factor according to degree of flexural rigidity in general soil nail wall and application of geosynthetic fiber soil nailing system is evaluated through laboratory tensile strength test and field pull-out test.

  • PDF

인발시험을 통한 스파이럴 볼트의 지보특성 (Supporting Characteristics of a Spiral Bolt through Pull-out Test)

  • 김장원;강추원;송하림
    • 화약ㆍ발파
    • /
    • 제29권1호
    • /
    • pp.10-16
    • /
    • 2011
  • 대규모 사면이나 암반구조물의 불안정한 지반을 새로운 평형상태로 유지시키기 위한 지보재로서 그라운 드 앵커, 케이블 볼트, 록 볼트와 최근 새로운 형태로 개발된 지보재인 스파이럴 볼트가 있다. 이에 본 연구에서는 현재 가장 널리 이용되고 있는 지보재인 록 볼트와 새롭게 개발되고 있는 스파이럴 볼트를 대상으로 터널 내 현장 인발시험을 수행하여 지보재의 특성을 분석하였다. 최대인발하중의 변화 양상을 살펴보기 위해 수행한 스파이럴 볼트와 록 볼트에 대한 3회 재인발시험의 결과를 보면 스파이럴 볼트의 경우는 인발시험 횟수에 관계 없이 거의 일정함을 보였는데, 이것은 지보재가 최대인발하중에 도달할지라도 스파이럴 볼트와 충전재 사이에 파괴가 거의 일어나지 않으므로 일정한 최대인발하중을 보이는 것으로 판단된다. 반면에 록 볼트의 경우 인발시 험의 횟수가 증가할수록 인발하중은 점점 감소하였는데, 이것은 지보재가 최대인발하중에 도달할 때 록 볼트와 충전재 사이에 일부분 파괴가 발생함으로 인해서 나타나는 현상으로 판단된다.

지지부재를 설치한 띠형 강판보강재의 인발마찰 특성 평가 (Pull-Out Properties of Steel Strip Reinforcement with Transverse Steel Bar)

  • 이광우;조삼덕;주재우;박종범
    • 한국지반신소재학회논문집
    • /
    • 제6권3호
    • /
    • pp.31-37
    • /
    • 2007
  • 국외 수입에 의존하고 있는 띠형 강판 보강재를 대체할 수 있는 새로운 강(steel) 보강재로서, 강판과 지지부재를 결합한 새로운 형태의 보강재를 고안하였다. 개발 보강재는 폭${\times}$두께가 $65mm{\times}4.5mm$인 띠형 강판에 50cm 간격으로 11mm 직경의 천공구멍 및 돌기가 형성된 형태를 가지고 있으며, 인발저항력 증대를 위한 지지부재의 설치가 가능하다. 개발 보강재의 마찰특성 평가를 위한 전단마찰시험 및 인발시험 결과, 지지부재를 설치하면 보강재의 인발저항력이 크게 증가하는 것으로 나타났다.

  • PDF

개설된 직접전단시험기(CNS)를 이용한 보강재의 인발력 추정 (Estimation of Pull-out force by using modified Direct Shear Apparatus)

  • 유병선;이학무;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.145-154
    • /
    • 2003
  • When a nail pulled out in dense, granular soil, the soil in the vicinity of the nail tends to dilate, but its dilatancy results in a normal stress concentration at the soil/nail interface, thereby increasing the pull-out resistance of the inclusion. It is thought to be occurring within the resistance zone where the soil mass is at stationary state and the reinforcement are held in position by the soil, due to the friction or bond. In this paper, A series of direct shear and interface tests were conducted by using so called‘Constant Normal Stiffness Test Apparatus’which was modified and improved from the conventional direct shear box test rig. Unlikely the normal shear box test, this enables to simulate the different constraint effects of surrounding soil during shear under the conditions of constant stress and volume, constant normal stiffness. The aim of the research programme is to get better understanding of pull-out bond mechanism, thus to explore the possibility of evaluating the pull-out bond capacity of soil/reinforcement at the preliminary design stage from the laboratory test.

  • PDF