• 제목/요약/키워드: Puff model

검색결과 32건 처리시간 0.025초

유동장 수치해석이 포함된 퍼프모델을 이용한 오염물질의 확산 해석 (Pollutant Dispersion Analysis Using the Gaussian Puff Model with the Numerical Flowfield Information)

  • 정영래;박원규;박옥현
    • 한국전산유체공학회지
    • /
    • 제4권3호
    • /
    • pp.12-20
    • /
    • 1999
  • The computations of the flowfield and pollutant dispersion over a flat plate and the Russian hills of various slopes are described. The Gaussian plume and the puff model have been used to calculate concentration of pollutant. The Reynolds-averaged unsteady incompressible Navier-Stokes equation with low Reynolds κ-ε model has been used to calculate the flowfield. The flow data of a flat plate and the Russian hills from Navier-Stokes equation solutions has been used as the input data for the puff model. The computational results of flowfield agree well with experimental results of both a flat plate and Russian hills. The concentration prediction by the Gaussian plume model and the Gaussian puff model also agrees flirty well with experiments.

  • PDF

METREX 확산실험 자료를 이용한 INPUFF모델의 평가 (Evaluation of INPUFF Model Using METREX Tracer Diffusion Experiment Data)

  • 이종범;송은영;황윤성
    • 한국대기환경학회지
    • /
    • 제18권6호
    • /
    • pp.437-452
    • /
    • 2002
  • The Metropolitan Tracer Experiment (METREX) was performed over the Washington, D.C. area using two inert, non-deposition perfluorocarbon gases for over 1 year period (November 1983∼December 1984). Two perfluorocarbon gas tracers (PDCH, PMCH) were released simultaneously at intervals of every 36 hours for 6 hours, regardless of the meteorological conditions in metropolitan area. Samples were collected continuously for 8 hours at a central downtown and two adjacent suburban locations. Monthly air samples were collected at 93 sites across the whole region (at urban, suburban, and rural locations). The purpose of this study is to simulate INPUFF and ISCST model using METREX data, and to compare calculated and observed concentrations. In the case of INPUFF simulation, two meteorological input data were used. One is result data from wind field model which was calculated by diagnostic wind model (DWM), the other is meteorological data observed at single station. Here, three kinds of model calculation were performed during April and July 1984; they include (1) INPUFF model using DWM data (2) INPUFF model using single meteorological data (3) ISCST model. The monthly average concentration data were used for statistic analysis and to draw their horizontal distribution patterns. Eight-hour-averaged concentration was used to describe movement of puff during the episode period. The results showed that the concentrations calculated by puff model (INPUFF) were better than plume model (ISCST). In the case of puff model (INPUFF), a model run using wind field data produced better results than that derived by single meteorological data.

화생방 보고관리 및 모델링 S/W 시스템(NBC_RAMS)의 라그랑지안 퍼프 및 입자 모델에 따른 화학작용제 이송·확산 분석 (A Study on Transport and Dispersion of Chemical Agent According to Lagrangian Puff and Particle Models in NBC_RAMS)

  • 구혜윤;서지윤;남현우
    • 한국군사과학기술학회지
    • /
    • 제26권1호
    • /
    • pp.102-112
    • /
    • 2023
  • This research mainly focuses on the transport and dispersion of chemical agent plume according to the Lagrangian Puff Model and Lagrangian Particle Model of NBC_RAMS(Nuclear, Biological, Chemical Reporting And Modeling S/W System). NBC_RAMS was developed with the purposes of estimating the fate of Chemical, Biological, and Radioactive(CBR) agent plumes and evaluating damages in the Republic of Korea. First, it calculates the local weather pattern, i.e. wind speed, wind direction, and temperature, by considering the effects of land uses and topography. The plume behaviors are calculated by adopting the Lagrangian Puff Model(LPFM) or Lagrangian Particle Model(LPTM). In this research, we assumed a virtual chemical agent exposure event in a stable atmospheric condition during the summer season. The plume behaviors were estimated by both LPFM and LPTM on the used area(urbanized and dry area) and the agricultural land. The higher heat flux in the used area led to stronger winds and further downward movement moving of the chemical agent than the farmland. The lateral dispersion of the chemical plume was emphasized in the Lagrangian Puff Model because it adopted Gaussian distribution.

퍼프모형을 이용한 준설플륨의 혼합거동 모의 (Simulation of Mixing Behavior for Dredging Plume using Puff Model)

  • 김영도;박재현;이만수
    • 한국수자원학회논문집
    • /
    • 제42권10호
    • /
    • pp.891-896
    • /
    • 2009
  • 준설 시 발생하는 부유물의 이송 확산 과정을 해석하기 위하여 퍼프모형을 개발하였다. 본 연구에서 개발된 퍼프 모형은 추적방법에 따라 전방추적모형과 후방추적모형으로 나눌 수 있으며, 이 두 가지 추적방법은 계산효율과 수치 오차에 있어서 상이한 특성을 나타내었다. 경계처리에 있어서 입자추적모형과 상이한 방법을 사용하는 퍼프모형은 폐경계에서는 입자추적모형과 동일한 결과를 나타내지만 개경계에서는 다른 결과를 나타내었다. 또한 오염원이 임의의 공간적 분포를 갖는 경우, 퍼프모형은 입자추적모형보다는 적은 수의 퍼프를 사용할 수 있지만 이에 따른 경계면에서의 수치오차를 발생하였다. 흐름이 일정한 경우와 전단흐름의 경우에 대하여 이송 확산 수치모의를 수행하였으며, 이를 각각의 경우의 해석해 결과와 비교 분석하였다. 후방추적 퍼프모형은 전방추적 퍼프모형에 비하여 사용된 퍼프수와 관계없이 작은 오차를 발생하였으며, 전체적으로 퍼프모형이 입자모형보다는 훨씬 적은 수의 계산을 통해서도 작은 오차를 나타낼 수 있다는 것을 알 수 있었다. 그러나 Gaussian 분포를 갖는 퍼프모형은 전단흐름에서의 긴 유선형 농도분포를 모의할 수 없었고, 이에 관한 오차는 전단계수가 증가함에 따라 비선형적으로 증가하였다. 이와 같이 퍼프모형은 다양한 수환경에 적용할 경우, 뛰어난 효율성에 비해 정확도가 다소 감소하는 경향이 있지만, 입자추적모형과의 연계 모의 등을 통해 준설지점 인근의 근역에서의 오염원 해석에 사용될 수 있다.

RADAP-원자력 사고후 실시간 선량 예측용 PC 전산프로그램 (RADAP-A PC Program for Real-Time Prediction of Doses Following a Nuclear Accident)

  • Park, Jae-Won;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.102-109
    • /
    • 1993
  • 원자력시설의 사고에 따른 피폭선량 평가를 짧은 실시간에 대해 분석하는 PC 프로그램인 RADAP을 개발하였다. RADAP은 공기중 확산 및 수송에서 라그란지 puff 방법을 사용하고 있다. 실시간 분석을 위하여 한개 혹은 다중의 puff 를 동시에 취급할 수 있다. puff 내에서의 확산은 Gauss 분포를 가지며 , 확산계수는 USNRC 의 normal sigma curve 방법을 사용하였다. 그러나 이 프로그램은 바람조건에서 시간적인 변화만 적용하고 위치에 따른 변화는 취급하지 않았다. 31$\times$31 격자의 전신 및 갑상선 선량이 출력으로 나오며, EGA 및 VGA 모니터를 통하여 도상으로 표시된다. 결과에 의하면 RADAP은 사고후 짧은 시간동안의 선량을 평가하기 위한 좋은 도구라 할 수 있다.

  • PDF

추적자 확산실험에 의한 야간 강안정층하에서의 가우시안 퍼프모델의 평가 (Evaluation of Gaussian Puff Model with Tracer Experiment under Nighttime Strong Stable Conditions)

  • 이종범;김산;김용국;조창래;유승도
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.529-540
    • /
    • 1996
  • Dispersion experiment using SF$_{6}$ tracer was performed in the flat field of Chunchon Basin during four nights from August 29 to September 2, 1991. The purpose of this study is to analyze toe horizontal distribution of tracer concentration under the strong stable conditions and to evaluate the results calculated by INPUFF model. Incase of high wind speed, plume spread of SF$_{6}$ concentration appeared in narrow area of the downwind and the standard deviation of the horizontal wind angle (.sigma.$_{a}$) was amall. However, the SF$_{6}$ was spread widely in cases of low wind speed because of the large .sigma.$_{a}$. The result of the INPUFF model was similar to the observed distribution of the SF$_{6}$ concentration. It is proved that the Gaussian puff model is useful when wind direction varies significantly.tly.tly.tly.

  • PDF

CALPUFF와 HYSPLIT의 방사성물질 대기확산 특성 비교 (Comparison of CALPUFF and HYSPLIT Models for Atmospheric Dispersion Simulations of Radioactive Materials)

  • 안혜연;강윤희;송상근;김유근
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.573-584
    • /
    • 2015
  • In this study, the atmospheric dispersion of radioactive material ($^{137}Cs$) was simulated with regard to its impact within a 50-km radius from the Kori Nuclear Power Plant (NKPP) based on two different types of models (the non-steady-state puff model CALPUFF and the lagrangian model HYSPLIT) during the spring of 2012 (May 2012). The dispersion distribution of $^{137}Cs$ calculated in the CALPUFF model was similar to that of the HYSPLIT model, but the magnitudes of differences in its spatio-temporal concentrations between the two models were different. The $^{137}Cs$ concentrations simulated by the CALPUFF were significantly lower than those of the HYSPLIT due to a limitation of puff models (e.g. puff size growth over time). The CALPUFF had the advantage of determining the dispersion of radioactive materials and their impacts on the surrounding regions, compared with the HYSPLIT that had high concentrations of $^{137}Cs$ in only small local areas with the movement of air masses along the local winds.

The Real -Time Dispersion Modeling System

  • Koo, Youn-Seo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E4호
    • /
    • pp.215-221
    • /
    • 2002
  • The real-time modeling system, named AirWatch System, has been developed to evaluate the environmental impact from a large source. It consists of stack TMS (TeleMetering System) that measures the emission data from the source, AWS (Automatic Weather Station) that monitors the weather data and computer system with the dispersion modeling software. The modeling theories used in the system are Gaussian plume and puff models. The Gaussian plume model is used for the dispersion in the simple terrain with a point meteorological data while the puff model is for the dispersion in complex terrain with three dimensional wind fields. The AirWatch System predicts the impact of the emitted pollutants from the large source on the near-by environment on the real -time base and the alarm is issued to control the emission rate if the calculated concentrations exceed the modeling significance level.

The Intracisternal Administration of MEK Inhibitor Attenuates Mechanical and Cold Allodynia in a Rat Model of Compression of the Trigeminal Ganglion

  • Lee, Min-K.;Yoon, Jeong-H.;Park, Min-K.;Yang, Gwi-Y.;Won, Kyung-A.;Park, Yoon-Yub;Ahn, Dong-K.
    • International Journal of Oral Biology
    • /
    • 제35권3호
    • /
    • pp.75-81
    • /
    • 2010
  • The present study investigated the role of ERK in the onset of mechanical and cold allodynia in a rat model of compression of the trigeminal ganglion by examining changes in the air-puff thresholds and number of scratches following the intracisternal injection of PD98059, a MEK inhibitor. Male Sprague Dawley rats weighing between 250 and 260 g were used. Under anesthesia, the rats were mounted onto a stereotaxic frame and received 4% agar ($10\;{\mu}l$) solution to compress the trigeminal ganglion. In the control group, the animals were given a sham operation without the application of agar. Changes in behavior were examined at 3 days before and at 3, 7, 10, 14, 17, 21, 24, 30, and 40 days after surgery. Compression of the trigeminal ganglion significantly decreased the air-puff thresholds. Mechanical allodynia was established within 3 days and persisted over postoperative day 24. To evaluate cold allodynia, nociceptive scratching behavior was monitored after acetone application on the vibrissa pad of the rats. Compression of the trigeminal ganglion was found to produce significant cold allodynia, which persisted for more than 40 days after surgery. On postoperative day 14, the intracisternal administration of $1\;{\mu}g$ or $10\;{\mu}g$ of PD98059 in the rat model significantly decreased the air-puff thresholds on both the ipsilateral and contralateral side. The intracisternal administration of $10\;{\mu}g$ of PD98059 also significantly alleviated the cold allodynia, compared with the vehicle-treated group. These results suggest that central ERK plays an important role in the development of mechanical and cold allodynia in rats with compression of the trigeminal ganglion and that a targeted blockade of this pathway is a potential future treatment strategy for trigeminal neuralgia-like nociception.