• Title/Summary/Keyword: Public water supply

Search Result 185, Processing Time 0.027 seconds

Simulation of Contaminant Draining Strategy with User Participation in Water Distribution Networks

  • Marlim, Malvin S.;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.146-146
    • /
    • 2021
  • A contamination event occurring in water distribution networks (WDNs) needs to be handled with the appropriate mitigation strategy to protect public health safety and ensure water supply service continuation. Typically the mitigation phase consists of contaminant sensing, public warning, network inspection, and recovery. After the contaminant source has been detected and treated, contaminants still exist in the network, and the contaminated water should be flushed out. The recovery period is critical to remove any lingering contaminant in a rapid and non-detrimental manner. The contaminant flushing can be done in several ways. Conventionally, the opening of hydrants is applied to drain the contaminant out of the system. Relying on advanced information and communication technology (ICT) on WDN management, warning and information can be distributed fast through electronic media. Water utilities can inform their customers to participate in the contaminant flushing by opening and closing their house faucets to drain the contaminated water. The household draining strategy consists of determining sectors and timeslots of the WDN users based on hydraulic simulation. The number of sectors should be controlled to maintain sufficient pressure for faucet draining. The draining timeslot is determined through hydraulic simulation to identify the draining time required for each sector. The effectiveness of the strategy is evaluated using three measurements, such as Wasted Water (WW), Flushing Duration (FD), and Pipe Erosion (PE). The optimal draining strategy (i.e., group and timeslot allocation) in the WDN can be determined by minimizing the measures.

  • PDF

Investigation of Waterborne Parasites in Drinking Water Sources of Ankara, Turkey

  • Bilal Bakir;Mehmet Tanyuksel;Fatma Saylam;Sultan Tanriverdi;R. engin Araz;Hacim, Ali-Kasim;Metin Hasde
    • Journal of Microbiology
    • /
    • v.41 no.2
    • /
    • pp.148-151
    • /
    • 2003
  • Waterborne parasite infections are considered a reemerging threat. Most studies on the epidemiology of human cryptosporidiosis, giardiasis, and amebiasis have been carried out in developed countries, and there is little data on the occurrence of these infections in other areas. The objective of this study was to investigate the presence of waterborne parasites such as Cryptosporidium parvum, Giardia lamblia and Entamoeba histolytica in various water samples in Ankara, turkey. A total of 85 samples were examined, 43 from the municipal water supply, 34 from wells, 6 from the Ankara River, and 2 from two untreated dams; by conventional microscopy, immunologically and by polymerase chain reaction (PCR). Oocysts of C. parvum and cysts of G. lamblia were detected by using an indirect fluorescence (antigen) assay, whereas an enzyme linked immunosorbent assay was used to detect the cysts of E. histolytica and E. dispar. In addition, PCR was used for E. histolytica, E. dispar, C. parvum and G. lamblia detection. G. lamblia was found in 2 of the 34 well water samples, and parasites were found in 3 of the 6 Ankara River samples. The 1$\^$st/ contained E. histolytica cysts and Strongyloides stercoralis larvae. the 2$\^$nd/ E. histolytica cysts, and Trichuris trichiura eggs, and the 3$\^$rd/ C. parvum oocysts only. No parasite was observed in the municipal water samples and untreated dam water samples. These results extend our knowledge on waterborne parasites, such occurrence information on waterborne pathogens assists the management and treatment of municipal water.

Application of a Watershed-Based Land Prioritization Model for the Protection of Drinking Water Reservoir (상수원 보호를 위한 유역기반 토지관리 우선순위 모델 적용)

  • Lee, Jee Hyun;Choi, Ji Yang;Park, Seok Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.397-408
    • /
    • 2004
  • Due to the growing impact of non-point source pollution and limitation of water treatment technology, a new policy of water quality management, called a source protection, is now becoming more important in drinking water supply. The source protection means that the public agency purchases the pollution sensitive area, such as riparian zone, and prohibit locations of point and non-point sources. Many studies have reported that this new policy is more economical in drinking water supply than the conventional one. However, it is very difficult to determine location and size of the pollution sensitive zone in the watershed. In this paper, we presented the scientific criteria for the priority of the pollution sensitive zone, along with a case study of the upstream watershed of the Paldang Reservoir, Han River. This study includes applications of the analytical hierarchy process(AHP) and a watershed-based land prioritization(WLP) model. After major criteria affecting water quality were selected, the AHP and geographic analysis were performed. The WLP model allowed us to include both quantity and quality criteria, using AHP as the multi-criteria method in making decision and reflecting local characteristics and various needs. By adding a travel-time function, which represents the prototype effectively, the results secured adaptability and scientific objectivity as well. As such, the WLP model appeared to provide reasonable criteria in determining the prioritization of land acquisition. If the tested data are used with a validated travel-time and AHP method is applied after further discussion among experts in such field, highly reliable results can be obtained.

Causes of Burn and Emergency Care on the Spot for the Patients Admitted to Three Hospitals in Taegu (대구시내 종합병원에 입원한 화상환자의 화상원인과 현장에서 취한 응급처치)

  • Chu, Min;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.238-244
    • /
    • 1988
  • This study was conducted to investigate the causes of burn and emergency cares taken on the spot for the burn patient. Study population included 161 burn patients admitted to 2 university hospitals and 1 general hospital in Taegu from November 1, 1987 to April 30, 1988. Patients or guardians were interviewed with a structured questionnare. Out of 161 burn patients 111(68.9%)were males and 50(31.1%) females. Preschool children of 1-4 years old accounted for 29.8% of the total patients. Burns of children under 15 years of age took place at home in 91.0%, while 48.3% of burns of adult (15 years and over)males occurred at the working place, and 68.0% of adult females occurred at the home. Out of total burns occurred at home 39.8% took place at kitchen/dining room and 24.1% in the room. The most common cause of burns in children was the boiling water or hot food (74.3%). In adults the common causes were electrical burn(22.4%), hot water or food(19.0%) and explosion(12.1%) for males, and hot water or food(32.0%) and explosion (20.0%) for females. Common emergency cares for the burn taken on the spot were undressing(64.6%), pouring Soju(liquor)(13.7%), and pouring cold water(5.0%). There were a few cases who applied ash, soy or salt. To prevent burn, it is recommended to remodel the traditional kitchen and coal-briquet hole, to strengthen the safety control of LP Gas and LN Gas supply, to educate the public for the handling method for such gases, to strengthen the occupational safety control, to improve the safety device for the electric wire and socket, and to limit the temperature of hot water at home and public baths.

  • PDF

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

Occurrence of Arsenic, Strontium, and Selenium in Drinking Water in Kyungpook Province, Korea, in Relation to Geologic Formations (경북지역의 먹는 물에서 지질에 따른 비소, 스트론튬, 셀레늄 검출 특성)

  • Lee, Heageun;Cha, Sangdeok;Choi, Jeonhak;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.55-60
    • /
    • 2015
  • As the water supply system has been installed over the country, the management of drinking water could be easier and controlled by experts. This helps to supply safe water to public. However, in rural area, small scale water treatment systems or groundwater haves been used as drinking water supplier. The drinking water including groundwater contains various contaminants. Private or small scale water treatment system can be contaminated with heavy metals such as arsenic, selenium and strontium which are usually originated from natural source. Arsenic, selenium and strontium have been determined from the goundwater, small scale water treatment system in the Kyungpook area. The results have been compared with the Korean and international standards. The results were analyzed on the geological characteristics of the area. Among the total of 1,412 samples, 76 samples showed higher concentration of arsenic than WHO guideline and the Korean drinking water standard. Total 4 samples had higher contents of selenium than WHO guideline which was $10{\mu}g/L$. In the analysis of geological characteristics, arsenic was highly released from a few area and which are in order of biotite granodiorite > biotite granite > daegu formation. Selenium has been highly released from biotite granite > black shale > diluvium.

Long-Term Monitoring of Noxious Bacteria for Construction of Assurance Management System of Water Resources in Natural Status of the Republic of Korea

  • Bahk, Young Yil;Kim, Hyun Sook;Rhee, Ok-Jae;You, Kyung-A;Bae, Kyung Seon;Lee, Woojoo;Kim, Tong-Soo;Lee, Sang-Seob
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.10
    • /
    • pp.1516-1524
    • /
    • 2020
  • Climate change is expected to affect not only availability and quality of water, the valuable resource of human life on Earth, but also ultimately public health issue. A six-year monitoring (total 20 times) of Escherichia coli O157, Salmonella enterica, Legionella pneumophila, Shigella sonnei, Campylobacter jejuni, and Vibrio cholerae was conducted at five raw water sampling sites including two lakes, Hyundo region (Geum River) and two locations near Water Intake Plants of Han River (Guui region) and Nakdong River (Moolgeum region). A total 100 samples of 40 L water were tested. Most of the targeted bacteria were found in 77% of the samples and at least one of the target bacteria was detected (65%). Among all the detected bacteria, E. coli O157 were the most prevalent with a detection frequency of 22%, while S. sonnei was the least prevalent with a detection frequency of 2%. Nearly all the bacteria (except for S. sonnei) were present in samples from Lake Soyang, Lake Juam, and the Moolgeum region in Nakdong River, while C. jejuni was detected in those from the Guui region in Han River. During the six-year sampling period, individual targeted noxious bacteria in water samples exhibited seasonal patterns in their occurrence that were different from the indicator bacteria levels in the water samples. The fact that they were detected in the five Korea's representative water environments make it necessary to establish the chemical and biological analysis for noxious bacteria and sophisticated management systems in response to climate change.

Study on the Water Management to get High Quality of Drinking Water (이상적인 음료수 공급을 위한 수질관리에 관한 연구)

  • 김형석;신현덕;박경석
    • Journal of environmental and Sanitary engineering
    • /
    • v.6 no.1
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

Korea Water Resources Policy - from the viewpoint of Korean NGO's (NGO가 바라본 수자원 정책)

  • 김제남
    • Proceedings of the Korean Society of Environment and Ecology Conference
    • /
    • 2003.10a
    • /
    • pp.23-29
    • /
    • 2003
  • It has been declared in 1992 at Rio about the management of united water control and method of the management of the water resources at the water basin. And it was also mentioned about the protection of fresh water's quality and it's supply under chapter the 18th of the agenda 21. It has been 10years passed after Rio declaration, and water crisis Is getting more serious than before. Fairly, right for using water resources was given to every life as the public resources. But at the last world water forum, water was commercialized, and regulated as the basic requirement not basic right. Therefore, we could use the water according to the logic of supply and demand at the market, and with money. Furthermore, construction of the big dam which was build to solve the problem of the lack of water became one of problems for water control. Korea is keeping consistent policy such as providing water by the building of dam. Control of the water demand is the most basic and effective policy for the preservation of water resources. If we change the policy such as the construction of the dam, we should put the management of the water demand in the center with the reliable philosophy. United management of the river basin has to be made with the security of water, improvement of water quality, and protection of the ecological side each other. Management of water basin also has to be completed to solve the trouble caused by using water conflict people who live up and down stream. To maintain the good quality of water, management of water basin is necessary. Also, bottom line of the united management of water basin is voluntary involvement of every citizens and local community. We suggest to preserve the origin of river and the upper at the ecological side. It is worth it to preserve.

  • PDF

Molecular Epidemiology of Legionella pneumophila Isolated from Water Supply Systems in Seoul, Korea (서울시 수계시설에서 분리된 Legionella pneumophila의 분자역학적 특성)

  • Jeon, Su Jin;Jung, Ji Hun;Seung, Hyun Jung;Kim, Chang Kyu;Jin, Young Hee;Oh, Young Hee;Choi, Sung Min;Chae, Young Zoo
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.166-177
    • /
    • 2013
  • Objectives: The genus Legionella is common in aquatic environments. Some species of Legionella are recognized as potential opportunistic pathogens for human, notably Legionella pneumophila that causes, Legionellosis. Thus, we investigated the contamination of Legionella pneumophila on water supply systems in Seoul, including cooling towers, public baths, hospitals and fountains. Methods: The existence of 16S rRNA and mip gene of L. pneumophila was confirmed in the genome of the isolated strains by PCR. Results: During the summer season of 2010 and 2011, Legionella pneumophila were detected from 163 samples (21.1%) out of 772 samples collected. Among the 163 strains of L. pneumophila, eighty one isolates belonged to serogroup 1 (57.4%), 23 isolates were serogroup 5 (16.3%), 21 isolates were serogroup 6 (14.9%), 8 isolates were serogroup 2 (5.79%), and 8 isolates were identified in serogroup 3 (5.7%). Through PFGE (pulsed-field gel electrophoresis) analysis using Sfi I, genetic types of L. pneumophila were classified into five (A to E) patterns by the band similarity with excess of 70% from public baths. Conclusions: The PFGE patterns of the serotypes showed a tendency for diversity of L. pneumophila. Our results suggest the existence of serological and genetic diversity among the L. pneumophila isolates.