• Title/Summary/Keyword: Public Office Buildings

Search Result 100, Processing Time 0.029 seconds

The Variation Characteristics of Indoor Radon Concentration from Buildings with Different Environment, Seoul (서울지역 건축물의 환경적 특성에 따른 실내 라돈농도 변화)

  • Jeon, Jae-Sik;Lee, Ji-Young;Eom, Seok-Won;Chae, Young-Zoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.692-702
    • /
    • 2011
  • For more effective indoor radon reduction policy and technique, we researched radon data analysis for some buildings in Seoul. Those buildings were categorized as dwelling, underground and office space and the variations of radon concentration and its sources were evaluated. The variations of radon concentrations of indoor space of buildings for a day were patterned specifically by dwelling habits and different environment. As for the new built apartments which were not yet moved in, their indoor radon concentrations were showed more than 3 times after applying interior assembly, and were 5 times higher than ones of rather old residences. As for the subway stations, the radon concentrations during off-run times were about 15% higher than run-times. 10% of radon seemed to be reduced by installation of platform screen doors. As for office space, radon concentrations during working hours were about 2.5 times higher than non-working hours. Plaster board are expected as a main source of radon for them. By radon measurement method for long-term, its data can be over estimated because it covers non-active time in office or public space. Therefore combination of short and long-term measurement method is required for effective and economic reduction. Furthermore importance of ventilation is requested as public information service for all dwelling space. And also standardization for radium content or radiation of radon is necessary.

A Study on the Configuration and Placement of Bupyeong-office town in Ulsan county During Chosun Dynasty (조선시대 울산군 부평역촌의 구성과 배치에 관한 연구)

  • Hwang, Dae-Il
    • Journal of architectural history
    • /
    • v.23 no.1
    • /
    • pp.21-31
    • /
    • 2014
  • The paper analyzed the excavational data from Bupyeong-office in Ulsan county in Chosun Dynasty, examined the composition of the community estimated at station community, and studied the duration of the community by using the excavated relics. In addition, the paper compared the excavational data with documentary records, studied the location Bupyeong-office, and investigated the size of station community overall. Community compositions such as buildings, residential place, pits, stoves, hemp kilns, cremation tombs, and farming appliances were identified. When compared to excavated relics such as tiles, white porcelain jars, agrayish-blue-powdered celadons, and celadon porcelains from building, residance, and pits, the community existed during 14C~17C. The station location was on the west side to the quarters for Byongmajuldosa of the Left Gyeongsangdo at King's location according to the old maps and documentary records. It is widely expected that No, 201 foundation stone buildings at Pyungsan relic I was related to the station because there was a distinctions on the stone pillar waterway and high quality of location in the size(the front 9 sections ${\times}$ the side 1 section) and the community. According to the building's functions and duplication relations in the community, it is regarded that there were 33~40 ground buildings, 40~45 pitting buildings, storages or 15~30 other purpose buildings, and 5~7 public buildings around No, 210 building in Bupyeong-office town.

A Study on the Functional Mixed-use between School Buildings and Community Facilities (학교시설과 지역시설과의 복합화 방안에 관한 연구)

  • Kim, Seung-Je
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 2009
  • The purpose of this study is to have a guideline for mixed-use between school buildings and the community facilities as one of the suggestions to satisfy the needs of the society and to overcome the limitations of the supply of regional facilities. Main contents of this study are as a follow : 1) Arrangement of concept for mixed-use facilities, 2) Classification of community facilities for school buildings. 3) Distribution of school buildings in Nowon-Gu 4) Distribution of community facilities in Nowon-Gu 5) A proposal of mixed-use guide line between school buildings and public office.

Analysis of Trend on the Planning Characteristics for Publicity of the Low Level Area in the Headquarter Office Buildings (기업사옥 저층부의 공공성을 위한 계획특성 경향 분석)

  • Kang, Seon-Gyung;Song, Byung-Joon;Chu, Beom
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.178-186
    • /
    • 2014
  • Recently, a lower levels space has turned into a mediating space where people can experience urban spaces directly and it has revitalized communication between the city and company and also it has changed itself newly. In addition, this space which is connecting interior and exterior spaces of company's buildings can attract people living in the downtown as shock-absorbing and transitional space and it is getting more important part in urban context these days. Through case studies of corporate office space planning characteristics derived lower levels and to provide direction for the lower levels of the corporate office space planning purposes of the present study. Therefore, I establish the concept of the public good corporate office space and transition space, the concept of transition through the first Theoretical Methods. I investigate the properties of the transition area is used as the target for completion of the current construction culture destination since 2000, winning the corporate office, I have been talking about the characteristics of the corporate office along the lower part of the last PPS assessment criteria to apply to the building. PPS by applying an assessment factor can be derived for building enterprise case studies and analysis of the results the following conclusions about the use of publicity and transition space. First, lower levels of corporate office space had been applied to the use and activity in a very important project characteristics. Second, corporate office space, lower levels of access and linkages are important. Finally, in terms of public characteristics transition space is a important characteristic for low-rise space of headquarter buildings.

A Study on the Using Trends of Interior Materials in Current Medium Size Office Building in Seoul (최근 서울시 중형 OFFICE 건물의 실내재료의 사용경향에 관한 연구)

  • 김은중
    • Korean Institute of Interior Design Journal
    • /
    • no.23
    • /
    • pp.19-25
    • /
    • 2000
  • This study aims by analysing the interior design elements trends of current medium size office buildings in Seoul. The analysing objects are ceiling, floor, wall, and illumination plan of current office buildings. Analysing tools are finishing material and color of each part. Analysing areas are lobby area, deskwork area, conference area, welfare area, public area(rest room, corridor, stair). The interior design elements of lobby shows a lots of different features then the other areas in ceiling, floor, and wall design. Such difference appears at finishing material especially, and the coloring is more splendorous then the other areas. Desk work area and conference area have similar characteristics in finishing materiors and colors, and they usually follow the needs of function. Walfare area shows more splendorous feature then deskwork and conference area, and designed by various materials and colors. Public area also shows very active design concept then past times.

  • PDF

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

A Study on the Score of Issues by Certification Grade in the G-SEED for Office Buildings (업무용 건축물의 녹색건축 인증등급별 평가항목 득점에 관한 연구)

  • Hwang, Seonyoung;Tae, Choonseob;Shin, Ucheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.9-18
    • /
    • 2016
  • G-SEED(Green Standard for Energy and Environmental Design) is the certification system to evaluate environmental friendliness of buildings for the purpose of reducing environmental burden generated from the entire process of buildings, which is classified into 4 grades according to the evaluated score. Green building certification rule regulate to get over green 2nd grade for the public office buildings of $3000m^2$ or more. However, detailed measures on the applied level of each issue to obtain targeted certification grade have not been prepared yet. For each issue, the score distribution and the ratio of score in proportion to credit were analyzed by certification grade for office buildings which get the G-SEED certification. And applied level of issues were presented for each certification grade.

An Analysis on the Energy Consumption Unit of the Public buildings in Daegu (대구시 공공건축물의 에너지 소비 원단위에 관한 연구)

  • Choe, Jeong-Hui;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF

Market Acceptability of the ZEB Certification System for Public Buildings According to the 2025 Roadmap (2025년 의무화 로드맵에 따른 공공시설 제로에너지건축물 인증제도 시장 수용성)

  • Lee, Seung-Min;Kim, Jin-Ho;Shin, Gwang-Su;Kim, Eui-Jong
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.557-566
    • /
    • 2018
  • The ZEB certification system has come into effect since 2018 according to the ZEB road map. From 2020, the public buildings with the total floor area smaller than $3000m^2$ are the target of the certification, and it will be extended to the buildings with up to $5000m^2$ floor area in 2025. However, current mandatory regulations for public office buildings seem already to meet the ZEB certification system planned for 2025. In this work, two buildings belong to $3,000{\sim}5,000m^2$ in total floor area were selected to analyze the possibility of meeting the ZEB certification only by following current obligation regulations. Results showed that the test buildings satisfied the minimum building energy efficiency and energy self-sufficiency rates for the ZEB certification when the mandatory insulation and installation ratio of renewable energy are applied. This can be useful for revising the road map or extending the target buildings of the ZEB certification.

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF